Step
005
Perform the following steps:
Note:
When possible, run AIX online diagnostics in concurrent mode. AIX
online diagnostics perform more functions than the stand-alone
Diagnostics.
1.
Perform the AIX online diagnostics, see “Starting AIX concurrent
diagnostics” on page 189. Record any diagnostic results and see the
“Service request numbers (SRNs)” on page 141 to identify the failing
component.
Note:
When replacing a component, perform system verification for the
component. See “Using the diagnostics program” on page 192.
2.
If you cannot perform AIX concurrent online diagnostics, continue to
Step
006
.
Step
006
Perform the following steps:
1.
Use the management-module Web interface to make sure that the
device from which you load the stand-alone diagnostics is set as the
first device in the blade server boot sequence.
2.
Turn off the system unit power and wait 45 seconds before proceeding.
3.
Turn on the blade server and establish an SOL session.
4.
Check for the following responses:
a.
Progress codes are recorded in the management-module event log.
b.
Record any messages or diagnostic information that might be in the
log.
5.
Load the stand-alone diagnostics. Go to “Starting stand-alone
diagnostics from a CD” on page 190 or “Starting stand-alone
diagnostics from a NIM server” on page 191.
6.
If you have replaced the failing component, perform system verification
for the component. See “Using the diagnostics program” on page 192
This ends the AIX procedure.
Step
007
Perform the following steps:
1.
Use the management-module Web interface to make sure that the
device from which you load the stand-alone diagnostics is set as the
first device in the blade server boot sequence.
2.
Turn off the blade server and wait 45 seconds before proceeding.
3.
Turn on the blade server and establish an SOL session.
4.
Check for the following responses:
a.
Progress codes are recorded in the management-module event log.
b.
Record any messages or diagnostic information that might be in the
log.
Continue with step
008
.
Step
008
Load the stand-alone diagnostics. Go to “Starting stand-alone diagnostics
from a CD” on page 190 or “Starting stand-alone diagnostics from a NIM
server” on page 191.
Can you load the stand-alone diagnostics?
188
JS22 Type 7998: Problem Determination and Service Guide
Содержание BladeCenter JS22
Страница 1: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS22 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS22 Type 7998 Problem Determination and Service Guide...
Страница 286: ...272 JS22 Type 7998 Problem Determination and Service Guide...
Страница 294: ...280 JS22 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS22 Type 7998 Problem Determination and Service Guide...
Страница 308: ...294 JS22 Type 7998 Problem Determination and Service Guide...
Страница 313: ......
Страница 314: ...Part Number 44W2359 Printed in USA 1P P N 44W2359...