Table 24. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
FRU/action
A15-22x
Fan failure and Over temperature
condition.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A15-23x
Non-critical power problem, loss of
redundant power supply.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A15-24x
Power Fault specifically due to internal
battery failure.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A15-50x
Recoverable errors on resource indicate
a trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The
system is operating with the potential
for an unrecoverable error.
1.
If repair is not immediately available, reboot
and the resource will be deconfigured;
operations can continue in a degraded mode.
2.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
3.
If no entry is found, replace the system-board
and chassis assembly.
A1D-00x
A non-critical error has been detected.
Error log analysis indicates an error
detected by the Service Processor, but
the failure could not be isolated.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A1D-02x
A non-critical error has been detected,
an I/O (I2C) general bus error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A1D-04x
A non-critical error has been detected,
an internal service processor memory
error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
176
JS22 Type 7998: Problem Determination and Service Guide
Содержание BladeCenter JS22
Страница 1: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS22 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS22 Type 7998 Problem Determination and Service Guide...
Страница 286: ...272 JS22 Type 7998 Problem Determination and Service Guide...
Страница 294: ...280 JS22 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS22 Type 7998 Problem Determination and Service Guide...
Страница 308: ...294 JS22 Type 7998 Problem Determination and Service Guide...
Страница 313: ......
Страница 314: ...Part Number 44W2359 Printed in USA 1P P N 44W2359...