Table 22. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
254E-702
254E 221
Error log analysis indicates permanent adapter failure is reported on the other port
of this adapter. Go to “Performing the checkout procedure” on page 187.
2567-xxx
2567
USB integrated system-board and chassis assembly. Go to “Performing the checkout
procedure” on page 187.
256D-201
256D 221
Adapter configuration error.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
256D-601
256D
Error log analysis indicates adapter.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
256D-602
256D
Error log analysis indicates an error attention condition.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
256D-603
256D
Error Log Analysis indicates that the microcode could not be loaded on the adapter.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
256D-604
256D 210
Error Log Analysis indicates a permanent adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
256D-605
256D
Error Log Analysis indicates permanent adapter failure is reported on the other port
of this adapter.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
256D-606
256D
Error Log Analysis indicates adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
256D-701
256D 221
Error Log Analysis indicates permanent adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
Chapter 2. Diagnostics
155
Содержание BladeCenter JS22
Страница 1: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS22 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS22 Type 7998 Problem Determination and Service Guide...
Страница 286: ...272 JS22 Type 7998 Problem Determination and Service Guide...
Страница 294: ...280 JS22 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS22 Type 7998 Problem Determination and Service Guide...
Страница 308: ...294 JS22 Type 7998 Problem Determination and Service Guide...
Страница 313: ......
Страница 314: ...Part Number 44W2359 Printed in USA 1P P N 44W2359...