__ 8.
Remove the card filler plate.
__ 9.
Attention:
Adapter cards are fragile:
v
Handle only by the edges
v
Keep fingers off printed circuit area
v
Use static strap when handling
v
Leave in protective packaging until ready to install
__ 10.
Align the new adapter card with the card holders inside the system unit
and push until it is connected securely.
__ 11.
Swing the black latch in and move the blue latch clockwise or install the
screw to secure the card.
__ 12.
Go to “Connecting the Twinaxial cable attachment and Twinaxial console
cable”.
Connecting the Twinaxial cable attachment and Twinaxial console
cable
__ 1.
Find the 8-port Twinaxial cable attachment,
part number 21F5093
, and label
the cable,
for example, C05
.
__ 2.
Connect the 8-port Twinaxial cable attachment to the connector on the 2746
card.
Note:
Each port on the 8-port attachment cable supports 7 devices that
allow for 56 attached devices, of which only 40 can be
active
.
Figure 2. Example of 830, 840, SB2, SB3, 5079 Card Latches
6
AS/400e 270 or 820: Upgrading the System Unit from Operations Console to Twinaxial Console (5540)
Содержание AS/400e 270
Страница 2: ......
Страница 11: ...Figure 1 Example of 270 820 5075 Card Latch Before you begin 5...
Страница 18: ...12 AS 400e 270 or 820 Upgrading the System Unit from Operations Console to Twinaxial Console 5540...
Страница 26: ...20 AS 400e 270 or 820 Upgrading the System Unit from Operations Console to Twinaxial Console 5540...
Страница 33: ......