background image

Windows NT Setup
Setup could not determine the type of computer you have,
or you have chosen to manually specify the computer type.
Select the computer type from the following list, or select
"Other" if you have a device support disk provided by your
computer manufacturer.

Select

Other

and when prompted insert the diskette containing the updated

Uniprocessor HAL for your computer.

5. When this has been read proceed with the installation. You will be asked if you wish

to install any storage devices. Press

s

twice, and when asked to insert the

Manufacturer’s OEM diskette, place the latest SSA driver/installation diskette in the
drive (the latest version is available from the SSA World Wide Web site).

6. After returning to the

search for devices

panel, press

s

again, scroll up, and

select the appropriate CD-ROM driver for your server.

7. Proceed with the installation, and install NT on the 1GB partition created earlier. It

may be that NT will not accept the partition created under DOS, in which case,
delete and create the partition within the NT install process. We recommend that
you format with FAT.

8. Proceed with the installation. At the point where networking is installed, we

recommend you select:

Do not connect this computer to a network at this time.

and complete network installation after Service Pack 5 has been installed. See
“Network Installation” on page 16. You will have to re-apply SP5 after you have set
networking up.

9. Complete the installation of NT Server V4.0 as described in “Installing the Host

Software” on page 12.

Install Service Pack 5

Install Service Pack 5 on the Server. (This is the minimum level of NT Service Pack
required to operate the IBM Advanced SerialRAID/X adapter).

Upgrading a multiprocessor version

If the Intel Server is a multiprocessor machine, then upgrade the installed software to
the multiprocessor version.

1. If your machine has more than one Intel processor installed, then the HAL and

associated code needs to be upgraded to the multiprocessor version.

2. Before following this procedure we recommend that you should read articles:

Q156358

How to manually add support for a second processor

Q197896

Uptomp.exe requires access to the Txtsetup.sif file

from the Microsoft support Web site.

Chapter 4. Installing the Device Driver Software and Microcode

15

|
|
|
|
|
|

|
|

|
|
|
|

|
|

|
|
|
|

|
|

|

|
|
|

|
|

|
|
|

|
|
|

|
|

|

|
|

|
|

|

Содержание Advanced SerialRAID/X

Страница 1: ...age will load the necessary code into the correct directories as follows 1 c issa update driver which will contain the device driver software If asked to load device driver software from the CD ROM yo...

Страница 2: ......

Страница 3: ...IBM Advanced SerialRAID X Adapter Installation Guide SA33 3290 02...

Страница 4: ......

Страница 5: ...IBM Advanced SerialRAID X Adapter Installation Guide SA33 3290 02...

Страница 6: ...s will be incorporated in new editions of the publication The manufacturer may make improvements and or changes in the product s and or the program s described in this publication at any time without...

Страница 7: ...indows NT 4 0 11 Installation on an existing server 11 Installing NT onto an SSA Resource in a New Server 13 Verifying the Installation 16 Novell NetWare 4 2 18 Installing on an existing server 18 Ins...

Страница 8: ...atement 37 Electromagnetic Interference EMI Statement Taiwan 38 International Electrotechnical Commission IEC Statement 38 Avis de conformit aux normes de l Industrie Canada 38 Industry Canada Complia...

Страница 9: ...ithium battery can cause fire explosion or a severe burn Do not recharge disassemble heat above 100 C 212 F solder directly to the cell incinerate or expose cell to water Keep away from children Repla...

Страница 10: ...vi IBM Advanced SerialRAID X Adapter Installation Guide...

Страница 11: ...uring your system with the IBM Advanced SerialRAID X Adapter check the SSA World Wide Web Support page at http www hursley ibm com ssa Refer to the IBM Advanced SerialRAID X Adapter User s Guide and M...

Страница 12: ...viii IBM Advanced SerialRAID X Adapter Installation Guide...

Страница 13: ...andling the Adapter Attention Static electricity can damage this adapter and your system unit To avoid damage keep your adapter in its protective bag until you are ready to install To reduce the possi...

Страница 14: ...1 shows the card Adapter Card Lights On the IBM Advanced SerialRAID X Adapter card there is a light next to the pair of SSA connectors port 1 and port 2 for each SSA loop v The light is on continuousl...

Страница 15: ...the loop is not operational v The light is off if both ports are not operational Summary of Installation Procedures Installing the adapter consists of the following steps v Taking an inventory of all...

Страница 16: ...4 IBM Advanced SerialRAID X Adapter Installation Guide...

Страница 17: ...e SSA disk drives are installed for example the 7133 disk system v The plan for your SSA subsystem configuration v The documentation for the unit in which the SSA disk drives are installed Determining...

Страница 18: ...6 IBM Advanced SerialRAID X Adapter Installation Guide...

Страница 19: ...u have all the items required to install the IBM Advanced SerialRAID X Adapter 2 Refer to the User s Guide that shipped with your system unit to perform the following a Ensure that your system unit is...

Страница 20: ...Drives After you install the IBM Advanced SerialRAID X Adapter and reinstall the cover of your system unit you can connect the SSA disk drives To connect the disk drives 1 Refer to the configuration...

Страница 21: ...Advanced SerialRAID X Adapter User s Guide and Maintenance Information manual which is provided on the CD ROM 2 Your system unit documentation for information about running diagnostics or other proble...

Страница 22: ...10 IBM Advanced SerialRAID X Adapter Installation Guide...

Страница 23: ...rver on page 13 You must first install the appropriate adapter device driver See Installing the Device Driver After installing the device driver you must run the setup program on the CD ROM provided I...

Страница 24: ...BM Advanced SerialRAID X Adapter in the system unit and have installed the appropriate device driver Windows NT Networking must also be installed including the TCP IP protocol if installing the stand...

Страница 25: ...Adapter 4 If the Intel Server is a multiprocessor machine then upgrade the installed software to the multiprocessor version Notes 1 If you have an existing installation with Windows NT Server at Servi...

Страница 26: ...hould only create one resource at this time that is the resource that you want to install Windows NT on When the resource on which NT is to be installed is attached as a System Resource ensure the Res...

Страница 27: ...stall process We recommend that you format with FAT 8 Proceed with the installation At the point where networking is installed we recommend you select Do not connect this computer to a network at this...

Страница 28: ...tries to log on to the server they will get a message that says The local policy of this system does not permit you to log on interactively This can be easily remedied by logging on as the local admi...

Страница 29: ...r Netfinity password if security is enabled 4 On the first page Adapter List you should see as many SSA adapters as there are installed in your system unit and any remote adapters connected to a local...

Страница 30: ...SA Customer Support Homepage http www hursley ibm com ssa or have the diskette labeled Novell NetWare 4 11 4 2 Device Drivers that is provided with your adapter The following steps describe how to ins...

Страница 31: ...rs You can find instructions for doing this at Verifying the Installation on page 21 Installing NW onto an SSA Resource in a new server This section shows how to install and configure the adapter on a...

Страница 32: ...and press Enter The driver and support files will be copied to your system 8 The Driver ISSAV4E0 Parameter Actions menu will appear Choose Select Modify driver parameters and press Enter 9 Enter the...

Страница 33: ...ly loaded into memory 3 At the console enter load c nwserver issacfg nlm and then press Enter to load the ISSA configuration utility Once it has started select SSA Adapter List from the main menu and...

Страница 34: ...driver diskette into the drive and press Enter The system will scan the diskette present you with a menu of device drivers and ask you to Select a driver to install 7 Select ISSAV4E0 HAM and press En...

Страница 35: ...ort page http www hursley ibm com ssa or have the diskette labeled Novell NetWare 5 Device Drivers that is provided with your adapter 1 Insert the SSA disk that contains the PC DOS Configurator and bo...

Страница 36: ...Do so 11 When the server has restarted enter at the system console load c nwserver issainst and then press Enter 12 This will modify the autoexec ncf with two lines that load additional SSA nlms When...

Страница 37: ...Once it has started select SSA Adapter List from the main menu and press Enter You will see a display giving an entry for each SSA adapter installed in your system unit Select one of the adapters list...

Страница 38: ...26 IBM Advanced SerialRAID X Adapter Installation Guide...

Страница 39: ...below is for the microcode page you should visit it and get the latest packages The microcode files and download tools it copies to your hard drive usually to c issa update for Windows NT should be u...

Страница 40: ...crocode files as damage may be caused to adapters if the wrong image file is applied 5 When you are returned to the command prompt you have completed updating the adapter microcode and all modified ad...

Страница 41: ...types when later levels are released 7 When all appropriate drive types have been updated you have completed downloading the disk microcode and all modified drives will have been automatically reset E...

Страница 42: ...enclosure microcode To find out what level of software device driver or microcode you are using v View the device driver version on the RSM Adapter List page above the list of adapters v View the Eve...

Страница 43: ...at one connector of the SSA adapter and passes through a link SSA cable to the devices The loop continues through the devices then returns through another link to a second connector on the SSA adapte...

Страница 44: ...rted to the system In Figure 3 on page 33 disk drive number 3 has failed Disk drives 1 and 2 can communicate with the using system only through connector A1 of the SSA adapter Disk drives 4 through 8...

Страница 45: ...s 1 and 2 can communicate with the system only through connector A1 of the SSA adapter Disk drive number 8 can communicate with the system only through connector A2 of the SSA adapter Disk drives 4 5...

Страница 46: ...op v If you are not using RAID 0 arrays a second pair of adapter connectors can be connected in a particular SSA loop The second adapter must be another IBM Advanced SerialRAID X Adapter If an adapter...

Страница 47: ...se disks drives that are farthest round the loop from the adapter connectors By doing this you prevent the activity of the busiest disk drive from obstructing the data path to the other disk drives Fo...

Страница 48: ...36 IBM Advanced SerialRAID X Adapter Installation Guide...

Страница 49: ...rect the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits Neither the provider nor the manufacturer is responsible...

Страница 50: ...nt Regulations United Kingdom Telecommunications Requirements This apparatus is manufactured to the International Safety Standard EN60950 and as such is approved in the U K under approval number NS G...

Страница 51: ...t in bereinstimmung mit dem deutschen EMVG vom 9 Nov das EG Konformit tszeichen zu f hren Der Aussteller der Konformit tserkl rung ist die IBM Germany Dieses Ger t erf llt die Bedingungen der EN 55022...

Страница 52: ...40 IBM Advanced SerialRAID X Adapter Installation Guide...

Страница 53: ......

Страница 54: ...Part Number 27H0639 Printed in the U S A SA33 3290 02 27H0639...