SAS subsystem storage configurations
Several SAS subsystem storage configurations are supported on the 5105-22E, 9008-22L, 9009-22A,
9009-22G, 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-22H, 9223-22S, 9223-42H, or 9223-42S
systems.
The configuration you use depends on the combination of SAS features that you have installed on your
system. The following tables provide an overview of the features and related configurations for the
different systems.
Table 7. SAS subsystem storage configuration for 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, and 9223-22S systems
SAS subsystem
configuration
Supported SAS
RAID adapter
External SAS
components
SAS port cables
SAS cables
Limitations
Base function
storage
configuration
PCIe3 x8 SAS RAID
internal adapter 6
Gb (CCIN 57D7)
None
None
Internal 8x mini SAS HD
cables
Base function
storage
configuration
with the split-
disk feature
Two PCIe3 x8 SAS
RAID internal
adapters 6 Gb (CCIN
57D7)
None
None
Two internal 8x mini SAS
HD cables
Expanded
function storage
configuration
One PCIe3 x8 cache
SAS RAID internal
adapters 6 Gb (CCIN
57DC)
One external SAS 4x
ports that is used for
expansion to external
SAS storage enclosure
FC5887, ESLS, or ESLL
Yes
Two internal 8x mini SAS
HD cables
One external SAS storage
enclosure (FC 5887,
ESLS, or ESLL) is
supported from the
external SAS port.
Table 8. SAS subsystem storage configuration for 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, and 9223-42S systems
SAS subsystem
configuration
Supported SAS
RAID adapter
External SAS
components
SAS port cables
SAS cables
Limitations
Base function
storage
configuration
PCIe3 x8 SAS RAID
internal adapter 6
Gb 6 Gb (CCIN
57D7)
None
None
Internal 8x mini SAS HD
cables
Base function
storage
configuration
with the split-
disk feature
Two PCIe3 x8 SAS
RAID internal
adapters 6 Gb (CCIN
57D7)
None
None
Two internal mini SAS HD
cables
Expanded
function storage
configuration
Two PCIe3 x8 cache
SAS RAID internal
adapters 6 Gb (CCIN
57D8)
Two external SAS 4x
ports that are used for
expansion to external
SAS storage enclosure
(FC 5887, ESLS, or
ESLL)
Yes
Internal mini SAS HD
cables
One external SAS storage
enclosure (FC 5887,
ESLS, or ESLL) is
supported from the
external SAS port.
Related information
Serial-attached SCSI cable planning
SAS subsystem service considerations
SAS subsystem base function storage configuration for the 5105-22E, 9008-22L,
9009-22A, 9009-22G, 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-22H, 9223-22S,
9223-42H, or 9223-42S
This configuration uses the base function disk drive backplane.
The base function storage configuration for 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, and
9223-22S systems includes:
• One PCIe3 x8 SAS RAID internal adapter 6 Gb, with RAID 0,10,5,6
• One base function disk drive backplane that supports 8x SFF (2.5") bays
8 Power Systems: SAS subsystem