Before you begin
Attention:
When you place the system in the operating position, ensure that the cables at the rear of the
system do not catch or bind as you push the system unit back into the rack.
Procedure
1.
Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2.
Unlock the blue rail safety latches (A) by pushing them inward. Ensure that the cable management
arms can move freely. Ensure that the cables at the rear of the system do not catch or bind as you
push the system unit into the operating position.
3.
Push the system unit (B) back into the rack until both system unit release latches lock into position.
Secure the cable management arm with hook-and-loop fasteners around the back side of the cable
management arm, but not around the cables.
Power cords
Use these procedures to disconnect and connect the power cords in the 9008-22L, 9009-22A, or 9223-22H
system.
Disconnecting the power cords from the 9008-22L, 9009-22A, or
9223-22H system
Use this procedure to disconnect the power cords from the IBM Power System L922 (9008-22L), IBM
Power System S922 (9009-22A), or IBM Power System H922 (9223-22H) server.
Figure 35. Placing the system into the operating position
Common procedures for removing or replacing the system processor module
47
Содержание 9008-22L
Страница 1: ...Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H IBM...
Страница 2: ......
Страница 3: ...Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H IBM...
Страница 16: ...xiv Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H...
Страница 108: ...92 Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H...
Страница 109: ......
Страница 110: ...IBM...