Replacing a part by using the Systems Director Management Console
You can use the IBM Systems Director Management Console (SDMC) to perform many service actions,
including exchanging a field replaceable unit (FRU) or part.
If you are exchanging a part to repair a serviceable event follow those instructions.
1.
In the Power Systems Resource area, select the managed system in which you are exchanging a part.
2.
Select one of the following options:
v
If you are replacing a part that is not part of a serviceable event, from the
Actions
menu, expand
Service and Support
→
Hardware
→
Exchange FRU
.
v
If you are exchanging a part to repair a serviceable event, see Starting a repair action.
3.
To replace a part as part of a service action, select
Exchange FRU
.
4.
From the Exchange FRU tab, select the system or expansion unit in which you want to exchange a
part.
5.
Select the type of part you want to exchange from the menu and click
Next
.
6.
Select the location code of the part you want to exchange from the menu and click
Add
.
7.
After the FRU is placed in the
Pending actions
window, click
Launch Procedure
and follow the
instructions to exchange the part.
Note:
The SDMC might open external instructions for replacing the part. If so, follow those
instructions to replace the part.
66
Control panel, control panel fillers, and signal cables
Содержание 8203-E4A
Страница 1: ...Power Systems Control panel control panel fillers and signal cables ...
Страница 2: ......
Страница 3: ...Power Systems Control panel control panel fillers and signal cables ...
Страница 10: ...2 Control panel control panel fillers and signal cables ...
Страница 32: ...24 Control panel control panel fillers and signal cables ...
Страница 81: ......
Страница 82: ... Printed in USA ...