You can deactivate a system attention LED or a logical partition LED. For example, you might determine
that a problem is not a high priority and decide to repair the problem at a later time. However, you want
to be alerted if another problem occurs, so you must deactivate the system attention LED so that it can be
activated again if another problem occurs.
1.
In the navigation area, open
Systems Management
.
2.
Open
Servers
and select the appropriate system.
3.
In the content area, check the box for the appropriate Partition.
4.
Select
Tasks
, then
Operations
, and then
Manage Attention LED
.
5.
Select the appropriate Partition.
6.
Select
Deactivate System Attention LED
from the
Action
menu. A confirmation window is displayed
that provides the following information:
v
A verification that the system attention LED was deactivated.
v
An indication that there still might be open problems within the system.
v
An indication that you cannot activate the system attention LED.
7.
Select one of the logical partitions in the lower table, and select
Deactivate partition LED
from the
Partition Operations
menu. A confirmation window is displayed that provides the following
information:
v
A verification that the logical partition LED was deactivated.
v
An indication that there still might be open problems within the logical partition.
v
An indication that you cannot activate the logical partition LED.
Activating or deactivating identify LED:
The system provides several LEDs that help identify various components, such as enclosures or field
replaceable units (FRUs), in the system. For this reason, they are called identify LEDs.
You can activate or deactivate the following types of identify LEDs:
v
Identify LED for an enclosure
If you want to add an adapter to a specific drawer (enclosure), you
need to know the machine type, model, and serial number (MTMS) of the drawer. To determine
whether you have the correct MTMS for the drawer that needs the new adapter, you can activate the
LED in a drawer and verify that the MTMS corresponds to the drawer that requires the new adapter.
v
Identify LED for a FRU associated with a specified enclosure
If you want to hook up a cable to a
specific I/O adapter, you can activate the LED for the adapter which is a field replaceable unit (FRU),
and then physically check to see where you should hook up the cable. This is especially useful when
you have several adapters with open ports.
To activate or deactivate an identify LED for an enclosure or FRU, follow these steps:
1.
In the navigation area, open
Systems Management
.
2.
Select
Servers
.
3.
In the content area, check the box for the appropriate system.
4.
Select
Tasks
, then
Operations
, then
LED Status
, and then
Identify LED
.
5.
To activate or deactivate an identify LED for an enclosure, select an enclosure from the table, and click
either
Activate LED
or
Deactivate LED
. The associated LED is either turned on or off.
6.
To activate or deactivate an identify LED for a FRU, select an enclosure from the table, select
Selected
→
List FRUs
.
7.
Select one or more FRUs from the table, and click either
Activate LED
or
Deactivate LED
. The
associated LED is either turned on or off.
Viewing serviceable events
Use this procedure to view a serviceable event, including details, comments, and service history.
58
Control panel, control panel fillers, and signal cables
Содержание 8203-E4A
Страница 1: ...Power Systems Control panel control panel fillers and signal cables ...
Страница 2: ......
Страница 3: ...Power Systems Control panel control panel fillers and signal cables ...
Страница 10: ...2 Control panel control panel fillers and signal cables ...
Страница 32: ...24 Control panel control panel fillers and signal cables ...
Страница 81: ......
Страница 82: ... Printed in USA ...