Installing an adapter
Use this information to install an adapter.
Before you begin
The following notes describe the types of adapters that the server supports and
other information that you must consider when you install an adapter:
v
To confirm that the server supports the adapter that you are installing, see
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us.
v
Locate the documentation that comes with the adapter and follow those
instructions in addition to the instructions in this section.
v
Do not set the maximum digital video adapter resolution above 1600 x 1200 at
75 Hz for an LCD monitor. This is the highest resolution that is supported for
any add-on video adapter that you install in the server.
v
Avoid touching the components and gold-edge connectors on the adapter.
v
The server uses a rotational interrupt technique to configure PCI adapters so
that you can install PCI adapters that do not support sharing of PCI interrupts.
v
The following table lists the option part numbers and CRU part numbers for the
network adapters.
Table 32. Network adapters
Network Adapters
Description
Option part
number
CRU part number
NetXtreme II 1000 express Ethernet adapter
39Y6066
39Y6070
NetXtreme II 1000 express dual-port Ethernet adapter
42C1780
49Y7947
QLogic 10Gb CNA
42C1800
42C1802
QLogic 8Gb FC dual-port HBA
42D0510
42D0516
NetXtreme II 1000 express quad-port Ethernet adapter
49Y4220
49Y7949
Intel Ethernet dual-port server adapter I340-T2
49Y4230
49Y4232
Intel Ethernet quad-port server adapter I340-T4
49Y4240
49Y4242
Broadcom NetXtreme II dual-port 10GBaseT adapter
49Y7910
49Y7912
Intel X520-DA2 dual-port 10GbE SFP adapter
49Y7960
49Y7962
Intel X540-T2 dual-port 10GBaseT adapter
49Y7970
49Y7972
Broadcom NetXtreme I quad-port GbE adapter
90Y9352
90Y9355
Broadcom NetXtreme I dual-port GbE adapter
90Y9370
90Y9373
Emulex 10 GbE virtual fabric adapter III
95Y3762
9573766
Emulex 10 GbE virtual fabric adapter III lite
95Y3768
95Y3766
Attention:
Static electricity that is released to internal server components when
the server is powered-on might cause the server to stop, which might result in the
loss of data. To avoid this potential problem, always use an electrostatic-discharge
wrist strap or other grounding system when working inside the server with the
power on.
Read the safety information in “Safety” on page vii and “Installation guidelines”
on page 34.
242
System x3500 M4 Type 7383: Installation and Service Guide
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......