Memory problems
Table 21. Memory problems and actions
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom
Action
The amount of system memory
that is displayed is less than the
amount of installed physical
memory.
Note:
Each time you install or remove a DIMM, you must disconnect the server
from the power source; then, wait 10 seconds before restarting the server.
1.
Make sure that:
v
No error LEDs are lit on the operator information panel.
v
No DIMM error LEDs are lit on the system board.
v
Memory mirrored channel does not account for the discrepancy.
v
The memory modules are seated correctly.
v
You have installed the correct type of memory.
v
If you changed the memory, you updated the memory configuration in the
Setup utility.
v
All banks of memory are enabled. The server might have automatically
disabled a memory bank when it detected a problem, or a memory bank
might have been manually disabled.
v
There is no memory mismatch when the server is at the minimum memory
configuration.
2.
Reseat the DIMMs, and then restart the server.
3.
Check the POST error log:
v
If a DIMM was disabled by a systems-management interrupt (SMI), replace
the DIMM.
v
If a DIMM was disabled by the user or by POST, reseat the DIMM; then, run
the Setup utility and enable the DIMM.
4.
Check that all DIMMs are initialized in the Setup utility; then, run memory
diagnostics (see “Running DSA Preboot diagnostic programs” on page 149).
5.
Reverse the DIMMs between the channels (of the same microprocessor), and
then restart the server. If the problem is related to a DIMM, replace the failing
DIMM.
6.
Re-enable all DIMMs using the Setup utility, and then restart the server.
7.
(Trained technician only) Install the failing DIMM into a DIMM connector for
microprocessor 2 (if installed) to verify that the problem is not the
microprocessor or the DIMM connector.
8.
(Trained technician only) Replace the system board.
156
System x3500 M4 Type 7383: Installation and Service Guide
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...