7030 POWERstations 3AT, 3BT, and 3CT
Dimensions
Desktop
Deskside
Height
162 mm
6.4 in.
452 mm
17.8 in.
Width
442 mm
17.4 in.
280 mm
11.0 in.
(at pedestal for
deskside)
Depth
478 mm
18.5 in.
478 mm
18.8 in.
Weight
Minimum
18.1 kg 40 lbs.
Maximum
21.8 kg 48 lbs.
Electrical
Power source loading
0.35
(typical in kVA)
Voltage range (V ac)
100 to 125 or 200 to 240 (autoranging)
Frequency (hertz)
50 or 60
Thermal output
(typical)
770 Btu/hr
Power requirements
(typical)
225 watts
Power factor
0.5 to 0.7
Inrush current
³
42 amps at 120 V ac, 42 amps at 240 V ac
Maximum altitude
2135 m (7000 ft.)
Temperature
Requirements
Operating
16 to 32°C
(60 to 90°F)
Non-Operating
10 to 43°C
(50 to 110°F)
Humidity
Requirements
Operating
Non-Operating
(Noncondensing)
8 to 80%
8 to 80%
Wet Bulb
23°C (73°F)
27°C (80°F)
Noise Emissions
¹
Operating
Idle
L
WAd
5.5 bels
5.3 bels
L
pAm
41 dBA
41 dBA (desktop)
38 dBA
38 dBA (deskside)
<L
pA
>
m
41 dBA
41 dBA (desktop)
38 dBA
38 dBA (deskside)
Impulsive or
prominent discrete
tones
No
No
Clearances
Front
Back
Left
Right
Install/Air Flow
²
152 mm (6 in.)
152 mm (6 in.)
N/A
N/A
Service
760 mm (30 in.)
N/A
N/A
N/A
Footprint
2
Width
Depth
Desktop
442 mm (17.4 in.)
782 mm (30.8 in.)
Deskside
280 mm (11 in.)
782 mm (30.8 in.)
1. See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
2. The amount of space needed by the unit during normal operation is indicated by the footprint dimensions.
3. Inrush currents occur only at initial application of power, no inrush occurs during normal power off-on cycle.
Chapter 2. Physical Characteristics of Systems
85
Содержание 7012 397
Страница 1: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Страница 2: ......
Страница 3: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Страница 11: ...Appendix Notices 385 Index 387 Contents ix...
Страница 12: ...x Site and Hardware Planning Information...
Страница 16: ...xiv Site and Hardware Planning Information...
Страница 18: ...xvi Site and Hardware Planning Information...
Страница 26: ...8 Site and Hardware Planning Information...
Страница 238: ...220 Site and Hardware Planning Information...
Страница 246: ...228 Site and Hardware Planning Information...
Страница 284: ...266 Site and Hardware Planning Information...
Страница 296: ...278 Site and Hardware Planning Information...
Страница 366: ...348 Site and Hardware Planning Information...
Страница 372: ...Async Adapter Cable Planning Chart 354 Site and Hardware Planning Information...
Страница 374: ...128 Port Async Controller Cable Planning Chart Controller Line Interface 356 Site and Hardware Planning Information...
Страница 377: ...Standard I O Cable Planning Chart Chapter 12 Cable Planning 359...
Страница 380: ...Cable Planning Chart Other Adapters 362 Site and Hardware Planning Information...
Страница 382: ...7318 Serial Communications Network Server Cable Planning Chart 364 Site and Hardware Planning Information...
Страница 384: ...366 Site and Hardware Planning Information...
Страница 402: ...384 Site and Hardware Planning Information...
Страница 404: ...386 Site and Hardware Planning Information...
Страница 413: ......
Страница 414: ...Printed in USA SA38 0508 20...
Страница 415: ...Spine information RS 6000 and Eserver pSeries Site and Hardware Planning Information...