__
7.
Select
Start
a
service
tool
from
the
System
Service
Tools
(SST)
display.
Press
Enter.
__
8.
For
mirrored
disk
units
,
follow
these
steps
to
verify
that
the
disk
unit
you
are
replacing
has
been
suspended
before
powering
off
the
system:
__
a.
Select
Work
with
disk
units
from
the
System
Service
Tools
(SST)
display.
Press
Enter.
__
b.
Select
Display
Disk
Configuration
from
the
Work
with
Disk
Units
display.
Press
Enter.
__
c.
Select
Display
Disk
Configuration
Status
from
the
Display
Disk
Configuration
display.
Press
Enter.
__
d.
Does
the
disk
unit
that
is
mirrored
to
the
disk
unit
that
you
are
replacing
(same
unit
number)
have
a
status
of
Active
?
__
No
:
STOP!
Do
NOT
replace
the
disk
unit.
Contact
IBM
or
your
authorized
service
provider.
__
Yes
:
Does
the
disk
unit
that
you
are
replacing
have
a
status
of
Suspended
?
__
Yes
:
Continue
with
the
next
step.
__
No
:
Follow
these
steps
to
suspend
mirrored
protection
on
the
disk
unit
that
you
are
replacing:
1)
Press
F3
from
the
Display
Disk
Configuration
display
to
return
to
the
Work
with
Disk
Units
display.
2)
Select
Work
with
Disk
Unit
Recovery
from
the
Work
with
Disk
Units
display.
Press
Enter.
3)
Select
Suspend
mirrored
protection
from
the
Work
with
Disk
Unit
Recovery
display.
Press
Enter.
4)
Select
the
option
to
Suspend
the
disk
unit
that
you
are
replacing
from
the
Suspend
Mirrored
Protection
display.
Press
Enter.
5)
Press
F3
to
return
to
the
Work
with
Disk
Units
display.
6)
Press
F3
to
return
to
the
System
Service
Tools
(SST)
display.
7)
Select
Start
a
service
tool
from
the
System
Service
Tools
(SST)
display.
__
9.
Select
Hardware
service
manager
from
the
Start
a
Service
Tool
display.
Press
Enter.
__
10.
Select
Device
Concurrent
Maintenance
from
the
Hardware
Service
Manager
display.
Press
Enter.
__
11.
Type
the
Physical
Location
(Frame
ID
and
position)
where
you
will
be
replacing
the
disk
unit.
Note:
The
physical
location
of
the
disk
unit
to
be
replaced
should
have
been
provided
by
customer
support.
In
this
example,
Physical
Location:
Frame
ID
1____
Position
D06____
,
you
would
install
a
disk
unit
in
frame
1
(base
system),
disk
unit
position
6.
__
12.
Select
option
1
(Remove
device)
for
the
action
to
be
performed.
__
13.
Set
the
time
delay
for
one
minute—
01
.
Do
not
press
Enter
at
this
time.
4
43xx
Disk
Unit,
71xx
Disk
Expansion
Unit,
71xx
Disk
Unit
Enclosure
V5R3
Содержание 43 Series
Страница 1: ...iSeries 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure Version 5 ERserver ...
Страница 2: ......
Страница 3: ...iSeries 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure Version 5 ERserver ...
Страница 6: ...iv 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Страница 34: ...28 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Страница 37: ...270 800 or 810 in a rack Open or remove the front cover 31 ...
Страница 40: ...7104 or 7116 expansion unit 34 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Страница 41: ...820 system unit Disk unit locations 35 ...
Страница 42: ...825 system unit 36 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Страница 60: ...54 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Страница 66: ...60 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Страница 74: ...68 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Страница 76: ...70 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Страница 84: ...recommended cables and connectors 78 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Страница 85: ......
Страница 86: ... Printed in USA ...