Table 15. Operating environmental conditions for power supplies
Description
Range
Operating temperature
0° - 40°C (32° - 104°F)
Fan inlet temperature
43° - 45°C (109.4° - 113°F)
Fan vent temperature
52° - 53°C (125.6° - 127.4°F)
Relative humidity
20 - 90%, non-condensing
Operating altitude
Up to 3030 meters (10000 feet) above sea level
Operating noise
50 dBA
Cooling
AC: 40 mm, internal fans
Storage environment
Table 16. Storage environmental conditions for power supplies
Description
Range
Storage temperature
-40° to 85°C (-40° to 185°F)
Storage humidity
95% maximum, non-condensing
Storage altitude
4545.45 meter (15,000 feet) maximum
Power supply consumption
The maximum power supply consumption for each B24X model is 300W.
Input connector and plug
Table 17 lists the input connectors for the power supplies.
Table 17. Input connector for power supplies
Power Supply
Input Connector Properties
RPS11
Standard IEC 320
C16 type: UL/cUL 15A/250V, VDE 10A/250V
Orientation: Ground pin down
Figure 31 on page 50 shows the power plug and connector for AC power supplies.
Appendix A. Hardware Specifications
49
Содержание 4002AC2
Страница 2: ......
Страница 8: ...vi IBM x series of Ethernet Switches Installation and User Guide...
Страница 10: ...viii IBM x series of Ethernet Switches Installation and User Guide...
Страница 12: ...x IBM x series of Ethernet Switches Installation and User Guide...
Страница 34: ...8 IBM x series of Ethernet Switches Installation and User Guide...
Страница 44: ...18 IBM x series of Ethernet Switches Installation and User Guide...
Страница 56: ...30 IBM x series of Ethernet Switches Installation and User Guide...
Страница 68: ...42 IBM x series of Ethernet Switches Installation and User Guide...
Страница 81: ......
Страница 82: ...Part Number 45W5353 Printed in USA GC27 2267 00 1P P N 45W5353 53 1001490 01...