manualshive.com logo in svg
background image

Power Systems

Managing PCIe adapters for the Machine

Types 9008, 9009, 9040, 9080, 9223,

and the EMX0 PCIe3 expansion drawer

IBM

Содержание 00E2714

Страница 1: ...Power Systems Managing PCIe adapters for the Machine Types 9008 9009 9040 9080 9223 and the EMX0 PCIe3 expansion drawer IBM ...

Страница 2: ...l G229 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM Power Systems servers that contain the POWER9 processor and to all associated models Copyright International Business Machines Corporation 2018 2020 US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp ...

Страница 3: ...em 4 Managing PCIe adapters for the 9040 MR9 system 6 Managing PCIe adapters for the 9080 M9S system 9 PCIe adapter information by feature code 11 Reference information for managing PCIe adapters 49 Installing the AIX device driver software 49 Verifying the AIX device driver software 50 Upgrading a SAS RAID storage adapter 50 PCIe adapter details 50 Notices 219 Accessibility features for IBM Power...

Страница 4: ...iv ...

Страница 5: ...800 300 8751 German safety information Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne 2 der Bildschirmarbeitsverordnung geeignet Laser safety information IBM servers can use I O cards or features that are fiber optic based and that utilize lasers or LEDs Laser compliance IBM servers may be installed inside or outside of an IT equipment rack DANGER When working on or aro...

Страница 6: ...ces To Disconnect 1 Turn off everything unless instructed otherwise 2 For AC power remove the power cords from the outlets 3 For racks with a DC power distribution panel PDP turn off the circuit breakers located in the PDP and remove the power from the Customer s DC power source 4 Remove the signal cables from the connectors 5 Remove all cables from the devices To Connect 1 Turn off everything unl...

Страница 7: ... devices that attach to the system It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock R001 part 1 of 2 R001 part 2 of 2 CAUTION Do not install a unit in a rack where the internal rack ambient temperatures will exceed the manufacturer s recommended ambient temperature for all your rack mounted devices Do not install a un...

Страница 8: ...azards Verify that the route that you choose can support the weight of the loaded rack cabinet Refer to the documentation that comes with your rack cabinet for the weight of a loaded rack cabinet Verify that all door openings are at least 760 x 230 mm 30 x 80 in Ensure that all devices shelves drawers doors and cables are secure Ensure that the four leveling pads are raised to their highest positi...

Страница 9: ...y position for example when working from a ladder Stability hazard The rack may tip over causing serious personal injury Before extending the rack to the installation position read the installation instructions Do not put any load on the slide rail mounted equipment mounted in the installation position Do not leave the slide rail mounted equipment in the installation position L002 L003 or or or Sa...

Страница 10: ...duct might be equipped with multiple AC power cords or multiple DC power cables To remove all hazardous voltages disconnect all power cords and power cables L003 L007 CAUTION A hot surface nearby L007 x Power Systems Managing PCIe adapters ...

Страница 11: ...king into the other end of a disconnected optical fiber to verify the continuity of optic fibers may not injure the eye this procedure is potentially dangerous Therefore verifying the continuity of optical fibers by shining light into one end and looking at the other end is not recommended To verify continuity of a fiber optic cable use an optical light source and power meter C027 CAUTION This pro...

Страница 12: ... on off smooth platforms without appreciable force so take care not to push or lean Keep riser tilt adjustable angling platform option flat at all times except for final minor angle adjustment when needed Do not stand under overhanging load Do not use on uneven surface incline or decline major ramps Do not stack loads Do not operate while under the influence of drugs or alcohol Do not support ladd...

Страница 13: ...uitable for connection to intrabuilding or unexposed wiring or cabling only The intrabuilding ports of this equipment must not be metallically connected to the interfaces that connect to the OSP outside plant or its wiring These interfaces are designed for use as intrabuilding interfaces only Type 2 or Type 4 ports as described in GR 1089 CORE and require isolation from the exposed OSP cabling The...

Страница 14: ...xiv Power Systems Managing PCIe adapters ...

Страница 15: ...nt Interconnect X PCI X adapters If you attempt to force an adapter into the wrong type of slot you might damage the adapter or the slot A PCI adapter can be installed in a PCI X slot and a PCI X adapter can be installed in a PCI adapter slot A PCIe adapter cannot be installed in a PCI or PCI X adapter slot and a PCI or PCI X adapter cannot be installed in a PCIe slot The following illustration sh...

Страница 16: ...dant adapters from a single system to the same set of disks and disk arrays This feature is typically referred to as Multi Path I O MPIO MPIO support is part of the operating system support and can be used to provide a redundant IBM SAS RAID controller configuration with RAID protected disks For more information about the PCIe3 SAS RAID controllers see the following topics SAS RAID controllers for...

Страница 17: ...5269 POWER GXT145 PCI Express Graphics Accelerator The adapter information that is shown here is used during non directed service activities The information can be used to Identify an adapter Find specific technical information about an adapter Where applicable show special installation or cabling instructions Show signal names for the output pins of the adapter connectors Where applicable show th...

Страница 18: ...more information about the PCIe3 SAS RAID controllers see the following topics SAS RAID controllers for AIX SAS RAID controllers for IBM i SAS RAID controllers for Linux SAS subsystem for the 9040 MR9 Managing PCIe adapters for the 9009 41A 9009 42A or 9223 42H system Find information about using and managing the Peripheral Component Interconnect Express PCIe adapters that are supported for the IB...

Страница 19: ...Internal Adapter 6 Gb FC EJ1C CCIN 57D7 Adapter FRU number 01LK399 Storage backplane with integrated SAS controller for SAS bays and DVD in the system unit SAS bays are 2 5 inches or Small Form Factor SFF and use drives that are mounted on a carrier tray specific to the system unit SFF 3 The high performance SAS controller provides RAID 0 RAID 5 RAID 6 and RAID 10 support for either HDD or SSD JBO...

Страница 20: ... Power System E950 9040 MR9 server Also find information about specifications and installation notes for specific adapters Overview of managing PCIe adapters for the 9040 MR9 system Find information about using and managing Peripheral Component Interconnect Express PCIe adapters The following features are electromagnetic compatibility EMC Class B features See the Class B Notices in the Hardware No...

Страница 21: ...disk arrays It also supports one SAS AZ cable for internal SAS connection with two external mini SAS HD connectors This adapter must be installed in slot C12 Two FC EJ0K adapters are used in the split DASD disk drive backplane configuration EJSB that supports 8x SFF 2 5 bays Each EJ0K adapter controls four disk drive bays The SAS controllers provide RAID 0 5 6 and 10 support for disk arrays It als...

Страница 22: ...ckplane with 8x SFF 2 5 bays that are split into 4 4 One SAS AZ cable SAS bays are 2 5 inch or Small Form Factor SFF and used drives that are mounted on a carrier or tray specific to the system unit SFF 3 The storage bays are split into four storage bays each per adapter The high performance SAS controllers provide RAID 0 5 6 and 10 support for the HDD or SSD connectors JBOD for HDD is also suppor...

Страница 23: ...service activities The information can be used to Identify an adapter Find specific technical information about an adapter Where applicable show special installation or cabling instructions Show signal names for the output pins of the adapter connectors Where applicable show the settings for switches or jumpers Adapters can be identified by their feature code FC or their custom card identification...

Страница 24: ...AS bays 1 8 inch SSD cage bays if supported and DVD bay in the system unit Dual controllers also called dual I O adapters or paired controllers and their write cache are placed in integrated slots and do not use PCIe slots The high performance SAS controllers provide RAID 0 RAID 5 RAID 6 RAID 10 RAID 5T2 RAID 6T2 and RAID 10T2 support Patented Active Active configurations with at least two arrays ...

Страница 25: ... features If you are installing a new feature ensure that you have the software required to support the new feature and determine whether you must install any existing program temporary fix PTF prerequisites To do this use the Power Systems Prerequisites website www14 software ibm com support customercare iprt home Table 10 PCIe adapters supported in the 9008 22L 9009 22A 9009 41A 9009 42A 9040 MR...

Страница 26: ...er FC 5260 5899 EL4L and EL4M CCIN 576F Adapter part number 74Y4064 9008 22L FC EL4M 9009 22 A and 9223 22 H 9080 M9S 5269 POWER GXT145 PCI Express Graphics Accelerat or FC 5269 CCIN 5269 Adapter part number 74Y3227 9008 22L 9009 22 A and 9223 22 H 9080 M9S 5273 PCIe2 8 Gb dual port Fibre Channel adapter FC 5273 5735 EL2N and EL58 CCIN 577D Adapter part number 10N9824 9008 22L EL2N 9009 22 A and 9...

Страница 27: ...PCIe 1X adapter FC 5277 and 5785 CCIN 57D2 Adapter FRU number 46K6734 9008 22L 9009 22 A and 9223 22 H 9080 M9S 5729 PCIe2 FH 4 port 8 Gb Fibre Channel adapter FC 5729 CCIN 5729 Adapter part number 74Y3467 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 5735 8 Gb PCI Express dual port Fibre Channel adapter FC 5273 5735 EL2N and EL58 CCIN 577D Adapter part number 10N9824 9009 41 A 9009 42 A and 922...

Страница 28: ...s Graphics Accelerat or FC 5748 CCIN 5269 Adapter part number 10N7756 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 5785 4 port Async EIA 232 PCIe 1X adapter FC 5277 and 5785 CCIN 57D2 Adapter part number 46K6734 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 5899 PCIe2 4 port 1 GbE adapter FC 5260 5899 EL4L and EL4M CCIN 576F Adapter part number 74Y4064 9009 41 A 9009 42 A and 9223 42 H 9040 M...

Страница 29: ...2 port 10 GbE NIC RoCE SR adapter FC EC2M EC2N EL40 and EL54 CCIN 57BE Adapter part number full height tailstock 00RX875 low profile tailstock 00RX872 9008 22L EL40 9009 22 A and 9223 22 H 9080 M9S EC2N PCIe3 2 port 10 GbE NIC RoCE SR adapter FC EC2M EC2N EL40 and EL54 CCIN 57BE Adapter part number full height tailstock 00RX875 low profile tailstock 00RX872 9009 41 A 9009 42 A and 9223 42 H 9040 M...

Страница 30: ...C RoCE SR Cu adapter FC EC2R and EC2S CCIN 58FA Adapter part number 01FT759 9008 22L 9009 22 A and 9223 22 H 9080 M9S EC2S PCIe3 2 port 10 Gb NIC RoCE SR Cu adapter FC EC2R and EC2S CCIN 58FA Adapter part number 01FT759 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EC2T PCIe3 2 port 25 10 Gb NIC RoCE SFP28 adapter FC EC2T and EC2U CCIN 58FB Adapter part number 01FT756 9008 22L 9009 22 A and 9223...

Страница 31: ...pter FC EC2T and EC2U CCIN 58FB Adapter part number 01FT756 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EC37 PCIe3 LP 2 port 10 GbE NIC RoCE SFP Copper adapter FC EC37 EC38 EL3X and EL53 CCIN 57BC Adapter part number 00RX859 9008 22L EL3X 9009 22 A and 9223 22 H 9080 M9S EC38 PCIe3 2 port 10 GbE NIC RoCE SFP Copper adapter FC EC37 EC38 EL3X and EL53 CCIN 57BC Adapter part number 00RX859 9009 4...

Страница 32: ... 40 GbE NIC RoCE QSFP adapter FC EC3A and EC3B CCIN 57BD Adapter part number 00FW105 9008 22L 9009 22 A and 9223 22 H 9080 M9S EC3B PCIe3 2 Port 40 GbE NIC RoCE QSFP adapter FC EC3A and EC3B CCIN 57BD Adapter part number 00FW105 9009 41 A 9009 42 A and 9223 42 H EMX0 EC3E PCIe3 2 port 100 Gb EDR InfiniBan d adapter x16 FC EC3E and EC3F CCIN 2CEA Adapter part number 00WT075 9008 22L 9009 22 A and 9...

Страница 33: ... 100 Gb EDR InfiniBan d adapter x16 FC EC3E and EC3F CCIN 2CEA Adapter part number 00WT075 9009 41 A 9009 42 A and 9223 42 H EC3L PCIe3 2 port 100 GbE NIC RoCE QSFP28 adapter FC EC3L and EC3M CCIN 2CEC Adapter part number 00WT078 9008 22L 9009 22 A and 9223 22 H 9080 M9S EC3M PCIe3 2 port 100 GbE NIC RoCE QSFP28 adapter FC EC3L and EC3M CCIN 2CEC Adapter part number 00WT078 9009 41 A 9009 42 A and...

Страница 34: ...3U CCIN 2CEB Adapter part number 00WT013 9008 22L 9009 22 A and 9223 22 H 9080 M9S EC3U PCIe3 1 port 100 Gb EDR InfiniBan d adapter x16 FC EC3U CCIN 2CEB Adapter part number 00WT013 9009 41 A 9009 42 A and 9223 42 H EC42 PCIe2 3D Graphics adapter x1 FC EC42 Adapter part number 00E3980 9009 41 A 9009 42 A and 9223 42 H EMX0 EC45 PCIe2 4 port USB 3 0 adapter FC EC45 and EC46 CCIN 58F9 Adapter part n...

Страница 35: ...C46 PCIe2 4 port USB 3 0 adapter FC EC45 and EC46 CCIN 58F9 Adapter part number 00E2932 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EC51 PCIe2 LP 3D Graphics adapter x16 FC EC51 Adapter part number 00WT180 9008 22L 9009 22 A and 9223 22 H 9080 M9S EC59 PCIe3 2x4 NVMe M 2 internal carrier adapter FC EC59 Adapter part number 01DH181 9008 22L 9009 22 A and 9223 22 H 9009 41 A 9009 42 A and 9223 4...

Страница 36: ... on the following systems EC5B PCIe3 x8 Non Volatile Memory 1 6 TB SSD NVMe adapter FC EC5A EC5B EC5G EC6U and EC6V CCIN 58FC Adapter part number 01DH570 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EC5C PCIe3 x8 Non Volatile Memory 3 2 TB SSD NVMe adapter FC EC5C EC5D EC6W and EC6X CCIN 58FD Adapter part number 01LK431 9008 22L 9009 22 A and 9223 22 H 9080 M9S 22 Power Systems Managing PCIe adapter...

Страница 37: ...ipti on Supported on the following systems EC5D PCIe3 x8 Non Volatile Memory 3 2 TB SSD NVMe adapter FC EC5C EC5D EC6W and EC6X CCIN 58FD Adapter part number 01LK431 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EC5E PCIe3 x8 Non Volatile Memory 6 4 TB SSD NVMe adapter FC EC5E EC5F EC6Y and EC6Z CCIN 58FE Adapter part number 01LK435 9008 22L 9009 22 A 9080 M9S Managing PCIe adapters 23 ...

Страница 38: ... on the following systems EC5F PCIe3 x8 Non Volatile Memory 6 4 TB SSD NVMe adapter FC EC5E EC5F EC6Y and EC6Z CCIN 58FE Adapter part number 01LK435 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EC5G PCIe3 x8 Non Volatile Memory 1 6 TB SSD NVMe adapter FC EC5A EC5B EC5G EC6U and EC6V CCIN 58FC Adapter part number 01DH570 9008 22L 9009 22 A and 9223 22 H 9080 M9S 24 Power Systems Managing PCIe adapter...

Страница 39: ...d on the following systems EC62 PCIe4 x16 1 Port EDR 100 GB InfiniBan d ConnectX 5 CAPI capable adapter FC EC62 and EC63 CCIN 2CF1 Adapter part number 00WT179 9008 22L 9009 22 A and 9223 22 H 9080 M9S EC63 PCIe4 x16 1 Port EDR 100 GB InfiniBan d ConnectX 5 CAPI capable adapter FC EC62 and EC63 CCIN 2CF1 Adapter part number 00WT179 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 Managing PCIe adapters 2...

Страница 40: ...n the following systems EC64 PCIe4 x16 2 port EDR 100 GB InfiniBan d ConnectX 5 CAPI Capable adapter FC EC64 and EC65 CCIN 2CF2 Adapter part number 00WT176 9008 22L 9009 22 A and 9223 22 H EC65 PCIe4 x16 2 port EDR 100 GB InfiniBan d ConnectX 5 CAPI Capable adapter FC EC64 and EC65 CCIN 2CF2 Adapter part number 00WT176 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 26 Power Systems Managing PCIe adapt...

Страница 41: ...Descripti on Supported on the following systems EC66 PCIe4 x16 2 port 100 GB RoCE En ConnectX 5 adapter FC EC66 and EC67 CCIN 2CF3 Adapter part number 01FT742 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EC67 PCIe4 x16 2 port 100 GB RoCE En ConnectX 5 adapter FC EC66 and EC67 CCIN 2CF3 Adapter part number 01FT742 9008 22L 9009 22 A and 9223 22 H 9080 M9S Managing PCIe adapters 27 ...

Страница 42: ...cripti on Supported on the following systems EC6U PCIe3 x8 Non Volatile Memory 1 6 TB SSD NVMe adapter FC EC5A EC5B EC5G EC6U and EC6V CCIN 58FC Adapter part number 01DH570 9080 M9S EC6V PCIe3 x8 Non Volatile Memory 1 6 TB SSD NVMe adapter FC EC5A EC5B EC5G EC6U and EC6V CCIN 58FC Adapter part number 01DH570 9009 41 A 9009 42 A and 9223 42 H 28 Power Systems Managing PCIe adapters ...

Страница 43: ...ure code Descripti on Supported on the following systems EC6W PCIe3 x8 Non Volatile Memory 3 2 TB SSD NVMe adapter FC EC5C EC5D EC6W and EC6X CCIN 58FD Adapter part number 01LK431 9080 M9S EC6X PCIe3 x8 Non Volatile Memory 3 2 TB SSD NVMe adapter FC EC5C EC5D EC6W and EC6X CCIN 58FD Adapter part number 01LK431 9009 41 A 9009 42 A and 9223 42 H Managing PCIe adapters 29 ...

Страница 44: ...e Descripti on Supported on the following systems EC6Y PCIe3 x8 Non Volatile Memory 6 4 TB SSD NVMe adapter FC EC5E EC5F EC6Y and EC6Z CCIN 58FE Adapter part number 01LK435 9080 M9S EC6Z PCIe3 x8 Non Volatile Memory 6 4 TB SSD NVMe adapter FC EC5E EC5F EC6Y and EC6Z CCIN 58FE Adapter part number 01LK435 9009 41 A 9009 42 A and 9223 42 H 30 Power Systems Managing PCIe adapters ...

Страница 45: ...EJ05 PCIe3 cable adapter for the EMX0 PCIe Gen3 I O expansio n drawer FC EJ05 CCIN 2B1C Adapter part number 00RR809 9008 22L 9009 22 A EJ07 PCIe3 cable adapter for the EMX0 PCIe3 expansio n drawer FC EJ07 CCIN 6B52 Adapter part number 00TK704 9080 M9S EJ08 PCIe3 cable adapter for the EMX0 PCIe3 expansio n drawer FC EJ08 CCIN 2CE2 Adapter part number 41T9901 9009 41 A 9009 42 A and 9223 42 H 9040 M...

Страница 46: ... SAS RAID quad port 6 Gb adapter FC EJ0J and EL59 CCIN 57B4 Adapter part number 00FX846 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 FC EJ0J and FC EL59 EJ0K PCIe3 SAS RAID quad port 6 Gb x8 low profile capable adapter FC EJ0K CCIN 57B4 9040 MR9 EJ0L PCIe3 12 GB Cache SAS RAID quad port 6 Gb adapter FC EJ0L CCIN 57CE Adapter part number 00FX840 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 32...

Страница 47: ...uad port 6 Gb LP adapter FC EJ0M and EL3B CCIN 57B4 Adapter part number 00MH910 9008 22L FC EL3B 9009 22 A and 9223 22 H 9080 M9S EJ10 PCIe3 4 x8 SAS Port adapter FC EL60 EL65 EJ10 and EJ11 CCIN 57B4 Adapter part number 00MH959 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EJ11 PCIe3 4 x8 SAS Port adapter FC EL60 EL65 EJ10 and EJ11 CCIN 57B4 Adapter part number 00MH959 9008 22L FC EL60 9009 22 A...

Страница 48: ...GB Cache RAID PLUS SAS adapter quad port 6 Gb x8 FC EJ14 CCIN 57B1 Adapter part number 01DH742 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EJ19 PCIe3 cable adapter for the EMX0 PCIe Gen3 I O expansio n drawer FC EJ19 CCIN 6B53 Adapter part number 02AE929 9080 M9S EJ1C PCIe3 x8 SAS RAID Internal adapter 6 Gb FC EJ1C and EJ1E CCIN 57D7 Adapter part number 01LK399 9009 41 A 9009 42 A and 9223 42 ...

Страница 49: ...cache SAS RAID internal adapter 6 Gb FC EJ1D and EJ1M CCIN 57D8 Adapter part number 01JC773 9009 41 A 9009 42 A and 9223 42 H EJ1E PCIe3 x8 SAS RAID Internal adapter 6 Gb FC EJ1C and EJ1E CCIN 57D7 Adapter part number 01LK399 9009 41 A 9009 42 A and 9223 42 H EJ1F and EJ1H PCIe3 x8 SAS RAID Internal adapter 6 Gb FC EJ1F EJ1H EL66 EL68 CCIN 57D7 Adapter part number 01LK399 9008 22L FC EL66 and EL68...

Страница 50: ...nternal adapter 6 Gb FC EJ1G and EL67 CCIN 57DC Adapter part number 01JC780 9008 22L FC EL67 9009 22 A and 9223 22 H EJ1N PCIe1 SAS Tape DV D dual port 3 Gb x8 adapter FC EJ1N and EJ1P CCIN 57B3 Adapter part number 44V4852 9008 22L 9009 22 A and 9223 22 H 9080 M9S EJ1P PCIe1 SAS Tape DV D dual port 3 Gb x8 adapter FC EJ1N and EJ1P CCIN 57B3 Adapter part number 44V4852 9009 41 A 9009 42 A and 9223 ...

Страница 51: ... PCIe3 cable adapter for the EMX0 PCIe Gen3 I O expansio n drawer FC EJ1R CCIN 58FF Adapter part number 02AE884 9008 22L 9009 22 A and 9223 22 H EJ20 PCIe3 cable adapter for the EMX0 PCIe Gen3 I O expansio n drawer FC EJ20 CCIN 2CF5 Adapter part number 02WF001 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EJ27 PCIe Crypto graphic Coproces sor FC EJ27 and EJ28 CCIN 476A Adapter part number 45D7948 904...

Страница 52: ...8 PCIe Crypto graphic Coproces sor FC EJ27 and EJ28 CCIN 476A Adapter part number 45D7948 9040 MR9 EMX0 EJ32 4767 00 1 Crypto graphic Coproces sor FC EJ32 and EJ33 CCIN 4767 Adapter part number 00LV501 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EJ33 4767 00 1 Crypto graphic Coproces sor FC EJ32 and EJ33 CCIN 4767 Adapter part number 00LV501 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 38 Power ...

Страница 53: ...r FC EL43 EL5B EN0A and EN0B CCIN 577F Adapter part number 00E3496 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 FC EL5B and FC EN0A EN0B PCIe3 16 Gb 2 port Fibre Channel adapter FC EL43 EL5B EN0A and EN0B CCIN 577F Adapter part number 00E9283 9008 22L 9009 22 A and 9223 22 H 9080 M9S EN0F PCIe2 8Gb 2 Port Fibre Channel adapter FC EL5Y EL5Z EN0F and EN0G CCIN 578D Adapter part number 00WT111 900...

Страница 54: ... EN0F and EN0G CCIN 578D Adapter part number 00WT111 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EN0H PCIe3 4 port 10 Gb FCoE and 1 GbE FC EL38 FC EL56 FC EN0H and FC EN0J CCIN 2B93 Adapter part number 00E3498 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 FC EL56 and FC EN0H EN0J PCIe3 4 port 10 Gb FCoE and 1 GbE FC EL38 FC EL56 FC EN0H and FC EN0J CCIN 2B93 Adapter part number 00E3498 9008 ...

Страница 55: ... PCIe3 4 port 10 Gb FCoE and 1 GbE copper and RJ45 adapter FC EL3C EL57 EN0K and EN0L CCIN 2CC1 Adapter part number 00E8140 FC EN0K and 00E3502 FC EN0L 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EN0L PCIe3 4 port 10 Gb FCoE and 1 GbE copper and RJ45 adapter FC EL3C EL57 EN0K and EN0L CCIN 2CC1 Adapter part number 00E8140 FC EN0K and 00E3502 FC EN0L 9008 22L FC EL3C 9009 22 A and 9223 22 H 908...

Страница 56: ... 1 GbE LR and RJ45 adapter FC EN0M and EN0N CCIN 2CC0 Adapter part number 00E8144 9040 MR9 EMX0 EN0N PCIe3 4 port 10 Gb FCoE and 1 GbE LR and RJ45 adapter FC EN0M and EN0N CCIN 2CC0 Adapter part number 00E8143 9008 22L 9009 22 A and 9223 22 H 9080 M9S EN0S PCIe2 4 port 10 Gb 1 GbE SR RJ45 adapter FC EN0S FC EN0T FC EN0U and FC EN0V CCIN 2CC3 Adapter part number 00E2715 9009 41 A 9009 42 A and 9223...

Страница 57: ...GbE SR RJ45 adapter FC EN0T CCIN 2CC3 Adapter part number 00E2715 9008 22L 9009 22 A and 9223 22 H 9080 M9S EN0U PCIe2 4 port 10 Gb 1 GbE Copper SFP RJ45 adapter FC EN0U CCIN 2CC3 Adapter part number 00E2715 low profile tailstock 00E2720 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EN0V PCIe2 LP 4 port 10 Gb 1 GbE copper SFP RJ45 adapter FC EN0V CCIN 2CC3 Adapter part number 00E2715 9008 22L 90...

Страница 58: ...ystems EN0W PCIe2 2 port 10 GbE BaseT RJ45 adapter FC EL3Z FC EL55 FC EN0W and FC EN0X CCIN 2CC4 Adapter part number Adapter part number 00E2714 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EN0X PCIe2 2 port 10 GbE BaseT RJ45 adapter FC EL3Z FC EL55 FC EN0W and FC EN0X CCIN 2CC4 Adapter part number Adapter part number 00E2714 9008 22L FC EL3Z 9009 22 A and 9223 22 H 9080 M9S 44 Power Systems Ma...

Страница 59: ...N EN0Y Adapter part number 74Y3923 9008 22L 9009 22 A and 9223 22 H 9080 M9S EN12 PCIe2 FH 4 port 8 Gb Fibre Channel adapter FC EN12 CCIN EN0Y Adapter part number 00WT107 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EN13 PCIe 2 line WAN with modem FC 2893 2894 EN13 EN14 CCIN 576C Part number 44V5323 9009 41 A 9009 42 A and 9223 42 H EMX0 EN14 PCIe 2 line WAN with modem FC 2893 2894 EN13 EN14 CC...

Страница 60: ...following systems EN15 PCIe3 4 port 10 GbE SR adapter FC EN15 and EN16 CCIN 2CE3 Adapter part number 00ND466 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EN16 PCIe3 4 port 10 GbE SR adapter FC EN15 and EN16 CCIN 2CE3 Adapter part number 00ND466 9080 M9S EN17 PCIe3 4 port 10 GbE SFP copper adapter FC EN17 and EN18 CCIN 2CE4 Adapter part number 00ND463 9040 MR9 EMX0 46 Power Systems Managing PCIe...

Страница 61: ...PX 4 port 10 GbE SFP copper adapter FC EN17 and EN18 CCIN 2CE4 Adapter part number 00ND463 9080 M9S EN1A PCIe3 8x 2 port Fibre Channel 32 Gb s FC EL5U EL5V EN1A and EN1B CCIN 578F Adapter part number 01FT703 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EN1B PCIe3 8x 2 port Fibre Channel 32 Gb s FC EL5U EL5V EN1A and EN1B CCIN 578F Adapter part number 01FT703 9008 22L FC EL5V 9009 22 A and 9223 ...

Страница 62: ...Gb s FC EL5W EL5X EN1C and EN1D CCIN 578E Adapter part number 01FT698 9009 41 A 9009 42 A and 9223 42 H 9040 MR9 EMX0 EN1D PCIe3 8x 4 port Fibre Channel 16 Gb s FC EL5W EL5X EN1C and EN1D CCIN 578E Adapter part number 01FT698 9008 22L FC EL5X 9009 22 A and 9223 22 H 9080 M9S ES14 NVMe 400 GB mainstrea m solid state drive FC ES14 Adapter part number 00LY537 9008 22L 9009 22 A and 9223 22 H 9009 41 ...

Страница 63: ...st 4 Press Enter The Install Additional Device Software window highlights the INPUT device directory for software option 5 Type the name of the input device that you are using or press F4 to select the input device from a list 6 Press Enter The Install Additional Device Software window highlights the SOFTWARE to install option 7 Press F4 to select List 8 Type to display the Find window 9 Type the ...

Страница 64: ...ata protection The T 10 DIF attaches three fields to each data block During the operation the DIFs can be checked at different points to detect data corruption or inappropriate use When upgrading from PCI X and PCIe SAS RAID storage adapters which did not utilize the T 10 DIF fields to PCIe2 or PCIe3 SAS RAID storage adapters an automatic conversion process is performed to generate the T 10 DIFs o...

Страница 65: ...he CIM Complex Impedance Matching version offered only in Australia and New Zealand Note FC EN13 and EN14 are only supported with the IBM i operating system Figure 2 PCIe Binary Synchronous Adapter Specifications Item Description Adapter FRU number 44V5323 Designed to comply with RoHS requirement I O bus architecture PCIe2 x4 Managing PCIe adapters 51 ...

Страница 66: ...bm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags info LinuxAlerts html PCIe2 4 port 1 GbE adapter FC 5260 FC 5899 FC EL4L and FC EL4M CCIN 576F Learn about the specifications and operating system requirements for the feature code FC 5260 FC 5899 FC EL4L and EL4M adapters Overview FC 5260 FC EL4M FC 58...

Страница 67: ...upports IEEE 802 1p Supports IEEE 802 3ab for TX Supports TCP checksum offload transmission control protocol TCP user datagram protocol UDP Internet Protocol IP for IPv4 and IPv6 Supports TCP segmentation or large send offload Supports EEPROM SPI and single EEPROM Supports interrupt levels INTA and MSI Hardware certifications FCC B UL CE VCCI BSMI CTICK MIC Network Controller MAC Intel 82571EB Com...

Страница 68: ...ot be purchased from IBM I O bus architecture PCIe2 x4 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V Form factor short low profile Connector information Two RJ 45 ports 54 Power...

Страница 69: ...tor or a configuration mismatch Operating system or partition requirements If you are installing a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and partition requirements see one of the following topics The latest ve...

Страница 70: ...e switches to set Mode selection is made through the software The figures below show the adapters Figure 5 PCIe POWER GXT145 graphics accelerator adapter and converter cable FC 5269 1 DVI connector 28 pin analog or digital 2 Converter cable with dual DVI I analog digital video connectors If your monitor has a DVI connector connect it directly to the main DVI connector labeled 1 3 of your converter...

Страница 71: ...d at resolutions up to 1600 x 1200 analog or 1280 x 1024 digital For systems or logical partitions running the AIX operating system when running with two monitors both monitors must have an analog connection with the same resolution up to 1600 x 1200 The image on the primary monitor is also displayed on the secondary monitor Display power management Video Electronics Standards Association VESA Dis...

Страница 72: ...r software www ibm com support knowledgecenter POWER9 p9hak pxhak_installing_devicedriver_aix htm Checking the console 1 If you continue to experience problems you can redirect the monitor to the new adapter using the chdisp command 2 If you continue to experience problems after you have checked your cables and tried the chdisp command run diagnostics Checking the adapter installation Verify that ...

Страница 73: ...L2N and FC EL58 CCIN 577D Learn about the specifications and operating system requirements for the feature code FC 5273 FC EL2N FC 5735 and FC 5738 adapters Overview FC 5273 and FC EL2N are low profile adapters FC 5735 and FC EL58 are full height adapters The PCIe 8 Gb 2 Port Fibre Channel adapter is a high performance adapter based on the Emulex e12002 PCIe Host Bus Adapter HBA Each port provides...

Страница 74: ...Figure 6 PCIe 8 Gb 2 Port Fibre Channel adapter FC 5273 and FC EL2N 60 Power Systems Managing PCIe adapters ...

Страница 75: ...e card and can also be purchased from IBM I O bus architecture PCI Express PCIe Base and Card Electromechanical CEM 2 0 x8 PCIe bus interface Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Vol...

Страница 76: ...Gbps 0 5 meters to 150 meters 1 64 feet to 492 12 feet 0 5 meters to 300 meters 1 64 feet to 984 25 feet 0 5 meters to 500 meters 1 64 feet to 1640 41 feet 4 25 Gbps 0 5 meters to 70 meters 1 64 feet to 229 65 feet 0 5 meters to 150 meters 1 64 feet to 492 12 feet 0 5 meters to 380 meters 1 64 feet to 1246 71 feet 8 5 Gbps 0 5 meters to 21 meters 1 64 feet to 68 89 feet 0 5 meters to 50 meters 1 6...

Страница 77: ... Restricted offline mode test active None Fast flash Off Debug monitor in restricted mode None Fast flash On Not defined None Fast flash Slow flash Debug monitor in test fixture mode None Fast flash Fast flash Debug monitor in remote debug mode None Fast flash Flashing Not defined None Replacing Fibre Channel adapters by using hot swap When hot swapping Fibre Channel adapters be aware that device ...

Страница 78: ... f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags info LinuxAlerts html PCIe 4 port Async EIA 232 1X adapter FC 5277 and 5785 CCIN 57D2 Learn about the features operating system requirements and installation procedures for the feature code FC 5277 and 5785 adapters Overview The PCIe 4 port Async EIA 232 1X adapter provides ...

Страница 79: ...Figure 8 PCIe 4 port Async EIA 232 1X adapter Managing PCIe adapters 65 ...

Страница 80: ...ture PCIe V1 0a 1x Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Busmaster No Adapter size PCIe 1x short form factor Connectors Adapter 68 pin SCSI Cable 68 pin SCSI to DB 9 pin shell 66 Powe...

Страница 81: ...wing topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID a...

Страница 82: ...iption FRU number 74Y3467 Designed to comply with RoHS requirement Wrap plug FRU number 12R9314 Note The wrap plug is included with the card and can also be purchased from IBM I O bus architecture PCI Express PCIe Base 2 0 and x8 PCIe bus interface 68 Power Systems Managing PCIe adapters ...

Страница 83: ...the supported distances for the three different cable types at the three different link speeds Table 16 Supported cable distances by link speed Cable type 2 125 Gbps 4 25 Gbps 8 5 Gbps OM3 0 5 m 500 m 0 5 m 380 m 0 5 m 150 m OM2 0 5 m 300 m 0 5 m 150 m 0 5 m 50 m OM1 0 5 m 150 m 0 5 m 70 m 0 5 m 21 m Adapter LED Green and yellow LEDs can be seen through openings in the mounting bracket of the adap...

Страница 84: ...Refer to specific storage device documentation for information about how to remove these additional devices The adapter has a unique worldwide port name WWPN Check the zoning and LUN assignments to ensure that the new adapter functions as expected Operating system or partition requirements If you are installing a new feature ensure that you have the software that is required to support the new fea...

Страница 85: ... Graphics Accelerator adapter is a PCI Express PCIe adapter that accelerates and enhances the system unit video The adapter has no hardware switches to set Mode selection is made through the software Figure 11 on page 71 shows the adapter and its connectors Figure 11 POWER GXT145 PCI Express Graphics Accelerator adapter 1 Primary DVI connector 28 pin analog or digital 2 Secondary DVI connector 28 ...

Страница 86: ...ed on the secondary connector at resolutions up to 1600 x 1200 analog or 1280 x 1024 digital For systems or logical partitions running AIX when running with two monitors both monitors must have an analog connection with the same resolution up to 1600 x 1200 The image on the primary monitor is also displayed on the secondary monitor Display power management Video Electronics Standards Association V...

Страница 87: ...vices pci 2b102725 X11 5 2 0 105 COMMITTED AIXwindows GXT145 Graphics devices pci 2b102725 diag 5 2 0 105 COMMITTED GXT145 Graphics Adapter devices pci 2b102725 rte 5 2 0 105 COMMITTED GXT145 Graphics Adapter If the POWER GXT145 device driver did not fully install reinstall the driver For instructions see Installing the AIX device driver software www ibm com support knowledgecenter POWER9 p9hak px...

Страница 88: ...E NIC and RoCE SR adapter This PCIe generation 3 adapter provides two 10 Gb SR optical fiber ports The adapter is a converged network adapter supporting both NIC and IBTA RoCE standard RoCE is Remote Direct Memory Access RDMA over Converged Ethernet Using RoCE the adapter can support significantly greater bandwidth with low latency and minimize CPU overhead by more efficiently using memory access ...

Страница 89: ...xisting software The adapter supports TCP checksum offload transmission control protocol TCP user datagram protocol UDP TCP segmentation Offload TSO for IPv4 and IPv6 Supports TCP segmentation or large send offload Supports EEPROM SPI and single EEPROM Compliant with European Union Directive 2002 95 EC on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equip...

Страница 90: ... PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V Form factor Short Cables Supports standard 10 Gb SR optical cabling and up to 300 m 984 25 ft cable length 76 Power Syste...

Страница 91: ...ite http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags info LinuxAlerts html PCIe3 2 port 10 Gb NIC RoCE SR Cu adapter FC EC2R and EC2S CCIN 58FA Learn about the specifications and operating system requirements for feature code FC EC2R and EC2S adapters Overview FC EC2R and EC2S are...

Страница 92: ...Figure 14 PCIe3 LP 2 port 10 Gb NIC RoCE SR Cu Adapter FC EC2R 78 Power Systems Managing PCIe adapters ...

Страница 93: ... 74Y7010 Twinax wrap plug 12R9314 Optical wrap plug I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V 12 V Managing PCIe adapters 79 ...

Страница 94: ...or more information about adapter cabling see the Cable and Transceiver information on page 80 Transceivers IBM qualifies and supports SFP optical transceiver FC EB46 to install into the adapter Customers can also use their own optical cabling and SFP optical transceiver for the other end The 10 Gb optical transceiver is capable up to 300 M through the OM3 cable or 82 M through OM2 cable Either on...

Страница 95: ...tion Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopd...

Страница 96: ...Figure 16 PCIe3 LP 2 port 25 10 Gb NIC RoCE SFP28 Adapter FC EC2T 82 Power Systems Managing PCIe adapters ...

Страница 97: ...er 74Y7010 Twinax wrap plug 12R9314 Optical wrap plug I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V 12 V Managing PCIe adapters 83 ...

Страница 98: ...ch end of these cables For more information about adapter cabling see Cable and Transceiver information on page 84 Transceivers For 25 GbE IBM qualifies and supports SFP28 optical transceiver FC EB47 to install into the adapter Customers can also use their own optical cabling and SFP28 optical transceiver for the other end The 25 Gb optical transceiver is capable up to 100 m through the OM4 cable ...

Страница 99: ...ve copper to SFP28 4x25 Gb Ethernet split cable EN01 10 Gb s 1 m 3 3 ft copper active twinax Ethernet cable EN02 10 Gb s 3 m 9 8 ft copper active twinax Ethernet cable EN03 10 Gb s 5 m 16 4 ft copper active twinax Ethernet cable EN03 10 Gb s 5 m 16 4 ft copper active twinax Ethernet cable Operating system or partition requirements If you are installing a new feature ensure that you have the softwa...

Страница 100: ...r is included with these cables See Cables on page 89 for details Each 10 Gb port provides Ethernet connectivity with a nominal data rate of 10 Gbps gigabits per second The adapter provides the following features The adapter is a PCIe3 NIC network convergence adapter The adapter supports RoCE and NIC functions but not concurrently on same adapter The adapter supports the following standards for th...

Страница 101: ...Figure 18 PCIe3 LP 2 port 10 GbE NIC RoCE SFP copper adapter FC EC37 and FC EL3X Managing PCIe adapters 87 ...

Страница 102: ...00RX856 I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V Form factor Short Cables See Cables on page 89 for details 88 Power Systems Managing PCIe ada...

Страница 103: ...tion requirements If you are installing a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and partition requirements see one of the following topics The latest version of enabling libraries and utilities can be download...

Страница 104: ...The link aggregation and failover features of the adapter are ideal for critical network applications that require redundancy and high availability The two 40 Gb quad 4 channel small form factor pluggable QSFP transceiver ports are used for connectivity with other servers or switches in the network Each QSFP port provides Ethernet connectivity with a nominal data rate of 40 gigabits per second Gbp...

Страница 105: ...Figure 21 PCIe3 LP 2 port 40 GbE NIC RoCE QSFP adapter FC EC3A Managing PCIe adapters 91 ...

Страница 106: ... p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V Form factor Short Cables See Cables on page 92 for details Cables This adapter feature requires the use of compatible QSFP 40 Gbps copper twinaxial active Ethernet cables for cabling over short distances See Figure 23 on page 93 for different views of the QSFP copper cable For distances over 5 meters use two optical...

Страница 107: ... cables 10 m 32 8 ft EB2J 41V2458 30 m 98 4 ft EB2K 45D6369 QSFP 40G BASE SR transceiver EB27 49Y7928 Operating system or partition requirements If you are installing a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system an...

Страница 108: ...ture code FC EC3E adapter Overview FC EC3E and EC3F are both the same adapter with different feature codes FC EC3E is a low profile adapter and FC EC3F is a full height adapter The PCIe3 2 port 100 Gb enhanced data rate EDR InfiniBand adapter provides high speed connectivity with other servers or InfiniBand switches Each port maximum of 100 Gb assumes that no other system and or switch bottlenecks...

Страница 109: ...3 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V Form factor Short low profile FC EC3E Short will full height tailstock FC EC3F Managing PCIe adapters 95 ...

Страница 110: ...me html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags info LinuxAlerts html PCIe3 2 port 100 GbE NIC RoCE QSFP28 Adapter FC EC3L and EC3M CCIN 2CEC Learn about the specifications and operating system requirements for the feature code FC EC3L and EC3M adapter Overview FC EC3L and EC3M are both the same adapter with different tail stock bracke...

Страница 111: ...e3 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V Form factor Short low profile FC EC3L Short with full height tailstock FC EC3M Managing PCIe adapters 97 ...

Страница 112: ...lly one of the cables can be copper and the other can be optical IBM also offers QSFP optical transceiver FC EB27 to install into the adapter and allowing the customer to use their own optical cabling and QSP28 optical transceiver for the other end Cable and Transceiver Matrix Feature code Description EB59 100Gbase SR4 Optical Transceiver MTP MPO cable purchased separately FC EB2J 10 M FC EB2K 30 ...

Страница 113: ... System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm ...

Страница 114: ...Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V Form factor Short low profile FC EC3T Short with full height tail stock FC EC3U 100 Power Systems Managing PCIe adapters ...

Страница 115: ...ge ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags info LinuxAlerts html PCIe2 3D Graphics Adapter ...

Страница 116: ...dards Association VESA Display Power Management Signaling DPMS Preparing for installation If you are installing the operating system at this time install the adapter before you install the operating system See Installing the adapter on page 102 for instructions If you are installing only the device driver for this adapter install the device driver software before you install the adapter Gathering ...

Страница 117: ...eshoot the problem Check the cables Check the device driver software installation Check the adapter installation Checking the cables 1 Ensure the monitor cables are connected to the correct adapter 2 If you have more than one video adapter be sure that each adapter is connected to a monitor 3 Verify that the connections are secure 4 If no log in prompt appears restart the system unit Checking the ...

Страница 118: ...requisites must be met for this feature and attaching devices For information about operating system and partition requirements see one of the following topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support customercare iprt home IBM SSIC System Storage Int...

Страница 119: ...the USB ports on the system or on the USB adapter only one keyboard can be used while the partition is booting up The adapter provides 2k electrically erasable and programmable read only memory EEPROM at 256 bytes The provides supports integrated dual speed USB transceivers Figure 28 PCIe2 LP 4 port USB 3 0 adapter FC EC45 Managing PCIe adapters 105 ...

Страница 120: ...s architecture PCIe 2 2 compliant Slot priority For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Busmaster Yes Form factor FC EC45 Short form factor half length FC EC46 Short form factor half length 106 Power Sy...

Страница 121: ...roperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags info LinuxAlerts html PCIe2 LP 3D Graphics Adapter x16 FC EC...

Страница 122: ...chitecture PCIe2 1 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Supported Systems POWER9 processor based systems 108 Power Systems Managing PCIe adapters ...

Страница 123: ...ollowing topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RA...

Страница 124: ...ported systems Important Ensure that the 01GY502 SAS divider is re installed and the 01GY494 SAS slot air block is in place if you re replacing the FC EC59 in slot P1 C49 f you re adding a second FC EC59 in slot P1 C50 the 01GY502 SAS divider and 01GY494 SAS slot air block must be removed Figure 31 PCIe3 2x4 NVMe M 2 internal carrier adapter Specifications Item Description Adapter FRU number 01DH1...

Страница 125: ...either a x8 or x16 PCIe Gen3 slot in the system and uses Non Volatile Memory Express NVMe NVMe is a high performance software interface that can read or write flash memory Compared to a Serial attached SCSI SAS or Serial Advanced Technology Attachment SATA solid state drive SSD the NVMe Flash adapter provides more read or write input or output operations per second IOPS and larger throughput GB se...

Страница 126: ...ement I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V 12 V 112 Power Systems Managing PCIe adapters ...

Страница 127: ...eight adapters FC EC5C and EC5D are supported on AIX or Linux operating systems FC EC6W and EC6X are supported on the IBM i operating system Overview The PCIe3 x8 NVMe 1 6 TB SSD NVMe adapter is a Peripheral Component Interconnect Express PCIe generation 3 Gen3 x8 adapter The adapter can be used in either a x8 or x16 PCIe Gen3 slot in the system and uses Non Volatile Memory Express NVMe NVMe is a ...

Страница 128: ... SSD NVMe Flash Adapter Specifications Item Description Adapter FRU number 01LK431 Designed to comply with RoHS requirement I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are wo...

Страница 129: ...operating system requirements for feature code FC EC5E EC5F EC6Y and EC6Z adapters FC EC5E and EC6Y are low profile adapters and EC5F and EC6Z are full height adapters FC EC5E and EC5F are supported on AIX or Linux operating systems FC EC6Y and EC6Z are supported on the IBM i operating system Overview The PCIe3 x8 NVMe 1 6 TB SSD NVMe adapter is a Peripheral Component Interconnect Express PCIe gen...

Страница 130: ...alue applications where the content in the adapter must be protected additional NVMe Flash adapters with OS mirroring or software Redundant Array of Independent Disks RAID are recommended This adapter is not supported in the PCIe Gen3 I O drawer Figure 34 PCIe3 x8 NVMe 6 4 TB SSD NVMe Flash Adapter Specifications Item Description Adapter FRU number 01LK435 Designed to comply with RoHS requirement ...

Страница 131: ...upport fixcentral Power Systems Prerequisites http www14 software ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the NVMe management tool can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home ht...

Страница 132: ...y with RoHS requirement I O bus architecture PCIe4 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on 118 Power Systems Managing PCIe adapters ...

Страница 133: ...port customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Al...

Страница 134: ...y with RoHS requirement I O bus architecture PCIe4 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on 120 Power Systems Managing PCIe adapters ...

Страница 135: ...home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 ...

Страница 136: ...Figure 37 2 port 100 GbE RoCE En Connectx 5 Gen4 PCIe x16 adapter FC EC66 122 Power Systems Managing PCIe adapters ...

Страница 137: ...knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Cables For 100G IBM offers either Direct Attach Copper DAC cables up to 2 M or Active Optical Cables AOC up to 100 M QSFP28 based transceivers are included on each end of these cables For more information about adapter cabling see the CHANGE TO LINK Cable and transceiver matrix Note For 40G IBM offers ...

Страница 138: ... matrix Table 28 Cable and transceiver matrix Feature Description EB59 100Gbase SR4 optical transceiver MTP MPO cable purchased separately FC EB2J 10 M FC EB2K 30 M EB5J QSFP28 Passive Copper 100 Gb Ethernet Cable 5 M EB5K QSFP28 Passive Copper 100 Gb Ethernet Cable 1 M EB5L QSFP28 Passive Copper 100 Gb Ethernet Cable 1 5 M EB5M QSFP28 Passive Copper 100 Gb Ethernet Cable 2 M EB5R QSFP28 AOC 100 G...

Страница 139: ...p www14 software ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For supp...

Страница 140: ...ls Note The Virtual Protocol Interconnect VPI feature is not supported on this adapter The adapter must be used only as an InfiniBand adapter Figure 39 1 port HDR 100 Gb InfiniBand ConnectX 6 adapter FC EC6E Specifications Item Description Adapter FRU number 02CM915 Designed to comply with RoHS requirement I O bus architecture PCIe4 x16 126 Power Systems Managing PCIe adapters ...

Страница 141: ...plitter cables that are listed in the table support connecting to an HDR 100 Gb adapter to an HDR 200 Gb switch Note An HDR 200 Gb switch port must be in split mode configuration when using the HDR 100 Gb splitter cables Table 29 Cable matrix Feature Description EB50 Copper EDR 100 GbE cable 0 5 M EB51 Copper EDR 100 GbE cable 1 M EB54 Copper EDR 100 GbE cable 1 5 M EB52 Copper EDR 100 GbE cable 2...

Страница 142: ...ystem Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm co...

Страница 143: ...ils Note The Virtual Protocol Interconnect VPI feature is not supported on this adapter The adapter must be used only as an InfiniBand adapter Figure 40 2 port HDR 100 Gb InfiniBand ConnectX 6 adapter FC EC6G Specifications Item Description Adapter FRU number 02CM912 Designed to comply with RoHS requirement I O bus architecture PCIe4 x16 Managing PCIe adapters 129 ...

Страница 144: ... cables that are listed in the table support connecting to an HDR 100 Gb adapter to an HDR 200 Gb switch Note An HDR 200 Gb switch port must be in split mode configuration when using the HDR 100 Gb splitter cables Table 30 Cable matrix Feature Description EB50 Copper EDR 100 GbE cable 0 5 M EB51 Copper EDR 100 GbE cable 1 M EB54 Copper EDR 100 GbE cable 1 5 M EB52 Copper EDR 100 GbE cable 2 M EB5A...

Страница 145: ...est version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities ip...

Страница 146: ...adapter is in the identify function state Specifications Item Description Adapter FRU number 000RR809 Designed to comply with RoHS requirement I O bus architecture PCIe3 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select t...

Страница 147: ...awer Note The FC EJ07 CCIN 6B52 adapter only works with the CCIN 50CB PCIe3 6 slot fanout module Figure 42 PCIe3 x16 GPU adapter Note The LEDs that are shown in Figure 42 on page 133 indicate the following states The green LED indicates link status If the green LED is on at least one PCIe link is in the trained state The amber LED indicates FRU identify If the amber LED is on it will blink at 2 Hz...

Страница 148: ...erating system requirements for the feature code FC EJ08 adapter Overview The FC EJ08 is a full height half length PCIe3 cable adapter The adapter provides two optical ports for the attachment of two expansion drawer cables One adapter supports the attachment of one PCIe3 6 slot fanout module in a EMX0 PCIe Gen3 I O expansion drawer Note The FC EJ08 CCIN 2CE2 adapter only works with the CCIN 50CB ...

Страница 149: ...t have write cache Figure 44 on page 136 shows the PCIe3 SAS RAID quad port 6 Gb adapter Important There is no FCoE support on POWER9 systems The adapter is a 64 bit 3 3 V bootable SAS adapter that provides RAID 0 5 6 10 5T2 6T2 and 10T2 capability and system level mirroring via the operating system The adapter provides both single and dual RAID controller configurations Dual controller configurat...

Страница 150: ...ed in or removed Figure 44 PCIe3 SAS RAID adapter Specifications Item Description Adapter FRU number 000FX846 Designed to comply with RoHS requirement Connector plug part number 00FW784 The connector plug is installed in an empty port and prevents damage to that port whenever a cable for the adjacent port connectors is plugged in or removed 136 Power Systems Managing PCIe adapters ...

Страница 151: ...itiator and high availability dual storage IOA configurations Support for multi initiator and high availability or single controller configurations Other important requirements for adapter installation If you are attaching a new or existing FC 5887 to an FC EJ0J adapter verify that the latest System Enclosure Services SES code is applied to the FC 5887 before attaching to the FC EJ0J adapter See t...

Страница 152: ...rage IOA all attached devices must run RAID JBOD 512 byte functionality is supported only in a single controller configuration based on the operating system Best performance is achieved when multiple RAID sets are configured and optimized under a pair of adapters in a high availability multi initiator RAID configuration dual storage IOA which allows for an Active Active mode of operation Note Dual...

Страница 153: ... Hazardous Substances RoHS requirement Connector plug part number 00FW784 The connector plug is installed in an empty port and prevents damage to that port whenever a cable for the adjacent port connectors is plugged in or removed I O bus architecture PCIe 3 0 but compatible to PCIe 2 0 or PCIe 1 0 slots Managing PCIe adapters 139 ...

Страница 154: ...ns Other important requirements for adapter installation An automatic sector conversion takes place for use with the new adapter when migrating existing SAS disk enclosures and devices from existing previous PCIe SAS adapters to PCIe3 SAS adapters For more information about the migration procedures see Upgrading a SAS RAID storage adapter Operating system or partition requirements If you are insta...

Страница 155: ... the operating system The adapter must be installed in pairs and must be used in a high availability multi initiator RAID configuration with two adapters in dual controller mode dual storage IOA configuration Two FC EJ0L adapters provide additional performance and adapter redundancy with mirrored write cache data and mirrored RAID parity footprints between the adapters If the FC EJ0L pairing is br...

Страница 156: ...Every FC EJ0L requires another FC EJ0L on this server or on another server which pairs with the SAS RAID adapter and enables cache functionality and the other multi initiator high availability dual storage IOA functions Best performance is achieved when multiple RAID sets are configured and optimized under a pair of adapters in a high availability multi initiator RAID configuration dual storage IO...

Страница 157: ...eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V Form factor Short full height Cables Specific X YO or AA SAS cable features with new narrow HD connectors are used to attach to the other adapter or expansion drawers Special cabling is required for multi initiator and high availability configurations For more information see Serial attached SCSI cable planning A...

Страница 158: ...latile adapter write cache of up to 1 Gb compressed for improved performance This support is available with the 2 4 10 version of the iprutils utility available from the IBM Linux Power Tools Repository http www14 software ibm com webapp set2 sas f lopdiags yum html and with the latest adapter firmware available from the Fix Central website http www ibm com support fixcentral The adapter is a 64 b...

Страница 159: ... adjacent port connectors is plugged in or removed I O bus architecture PCIe 3 0 but compatible to PCIe 2 0 or PCIe 1 0 slots Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V Form ...

Страница 160: ...partition requirements If you are installing a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and partition requirements see one of the following topics The latest version of enabling libraries and utilities can be dow...

Страница 161: ...n be attached by using four YE1 cables ECBZ Externally attached devices are designed to run at a maximum data rate of 6 Gbps for SAS tape devices Important See the SAS RAID controllers for AIX SAS RAID controllers for IBM i or SAS RAID controllers for Linux topics for more information and important considerations for multi initiator and high availability or dual storage IOA configurations Figure 4...

Страница 162: ...mply with RoHS requirement Connector plug part number 00FW784 The connector plug is installed in an empty port and prevents damage to that port whenever a cable for the adjacent port connectors is plugged in or removed I O bus architecture PCIe 3 0 but compatible to PCIe 2 0 or PCIe 1 0 slots 148 Power Systems Managing PCIe adapters ...

Страница 163: ...about operating system and partition requirements see one of the following topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interopera...

Страница 164: ...is performed through the SAS fabric by way of the disk enclosures and cabling A maximum of 96 SAS devices are supported using four ESLS storage enclosures or 5887 disk drive enclosures The SAS devices can be all HDDs or can have up to 48 SSD 48 HDDs HDDs must be on the 3rd and 4th ports They can have a maximum of 72 SSDs with no HDDs and must have an AA cable on the top port If there are over 48 S...

Страница 165: ...onnector plug part number 00FW784 The connector plug is installed in an empty port and prevents damage to that port whenever a cable for the adjacent port connectors is plugged in or removed I O bus architecture PCIe 3 0 compatible with 2 0 and 1 0 Slot requirement One PCIe x8 slot per adapter Adapters are installed in pairs Managing PCIe adapters 151 ...

Страница 166: ...ling a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and partition requirements see one of the following topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm co...

Страница 167: ...tes that the adapter is in the identify function state Specifications Item Description Adapter FRU number 02AE929 Designed to comply with RoHS requirement I O bus architecture PCIe3 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm ...

Страница 168: ...upports 12 numbers of 2 5 inches small form factor SFF hard disk drives HDDs or solid state drives SSDs FC EJ1C also supports a slim DVD bay The PCIe3 x8 SAS RAID internal adapter 6 Gb supports the drives to be used as just a bunch of disks JBOD or as a RAID The supported RAID is RAID 0 5 6 and 10 Two mini SAS HD cables connect the PCIe3 x8 SAS RAID internal adapter 6 Gb to the two SAS ports on th...

Страница 169: ...hat are supplied with the adapter Voltage 12 V Operating system or partition requirements If you are installing a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and partition requirements see one of the following topic...

Страница 170: ...IN 57D8 that are installed in the slots P1 C49 and P1 C50 Two mini SAS HD cables that attach to the expanded function storage backplane For information see Front SAS cable FC EJ0W provides a mini SAS HD cable with two external SAS ports that is installed in the system rear bulkhead in the slot P1 C6 For more information see Rear SAS cable The PCIe3 x8 cache SAS RAID internal adapter 6 Gb has a dat...

Страница 171: ...ons Item Description Adapter CCIN number 57D8 Adapter FRU number 01JC773 Designed to comply with Restriction of Hazardous Substances RoHS requirement I O bus architecture PCIe3 x8 Slot requirement Internal PCIe3 slot with x16 connector and x8 bus signaling per adapter Expanded function configuration Two adapters are installed in slot P1 C49 and P1 C50 Cables Two mini SAS HD cables part number 01ML...

Страница 172: ...r PCIe3 x8 SAS RAID internal adapter 6 Gb FC EJ1H or FC EL68 enables the base function storage backplane FC EJ1F to be configured as a split storage backplane in the 9008 22L 9009 22A or 9223 22H Overview The PCIe3 x8 SAS RAID internal adapter 6 Gb is an internal PCI Express PCIe generation 3 Gen3 serial attached SCSI SAS Random Array of Independent Disks RAID adapter that is integrated in the 900...

Страница 173: ...internal adapter 6 Gb The split storage backplane configuration supports the drives to be used as just a bunch of disks JBOD or as a RAID array The supported RAID levels are RAID 0 5 6 and 10 The preinstalled PCIe3 x8 SAS RAID internal adapter 6 Gb in slot P1 C49 controls drives D1 D2 D3 and D7 on the direct access storage device DASD backplane A PCIe3 x8 SAS RAID internal adapter 6 Gb in the othe...

Страница 174: ...composite storage backplane Overview The expanded function PCIe3 x8 cache SAS RAID internal adapter 6 Gb is an internal PCI Express generation 3 PCIe3 serial attached SCSI SAS RAID adapter The adapter is part of a composite feature of the storage backplane FC EJ1G and FC EL67 and contains the SAS RAID controller The high performance internal adapter is preinstalled in the dedicated internal PCIe3 ...

Страница 175: ... end The external SAS port is installed in slot P1 C10 The external SAS port is used to attach a FC ESLS ESLL or migrated 5887 drive enclosure by way of a mini SAS HD YO cable and must not exceed the maximum supported length of 3 meters Only one external SAS drive enclosure is supported and must be in zone mode 1 For more information see Rear SAS cable Figure 55 PCIe3 x8 cache SAS RAID internal ad...

Страница 176: ...st version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags info LinuxAlerts html PCIe1 SAS Tape DVD Dual port 3 Gb x8 Adapter FC EJ1N and EJ1P C...

Страница 177: ... com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Cables SAS device attachment requires specific cables that are provided with the subsystem or device features being attached See Serial attached SCSI cable planning Voltage 3 3 V Form factor Short low profile FC EJ1N Short with full height tailstock FC EJ1P Attributes Two external mini SAS...

Страница 178: ...er http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags info...

Страница 179: ...that the adapter is in the identify function state Specifications Item Description Adapter FRU number 02AE884 Designed to comply with RoHS requirement I O bus architecture PCIe3 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and ...

Страница 180: ...a EMX0 PCIe Gen3 I O expansion drawer Note The FC EJ20 CCIN 2CF5 adapter only works with the CCIN 50CD PCIe3 6 slot fanout module Figure 58 PCIe3 cable adapter Note The LEDs that are shown in Figure 58 on page 166 indicate the following states The green LED indicates link status If the green LED is on at least one PCIe link is in the trained state The amber LED indicates FRU identify If the amber ...

Страница 181: ...rfaces APIs and by the Public Key Cryptographic Standards PKCS11 The FC EJ27 and FC EJ28 provide secure storage of cryptographic keys in a tamper resistant hardware security module which is designed to meet FIPS PUB 140 2 on security requirements The FC EJ27 and FC EJ28 are the same adapter but the different FCs indicate if a blind swap cassette is used and the type of the cassette FC EJ27 is not ...

Страница 182: ...y disable Handling requirements Each PCIe Cryptographic Coprocessor includes a certified device key This electronic key which is stored in the adapter s battery powered and protected memory digitally signs status messages to confirm that the PCI Cryptographic Coprocessor is genuine and that no tampering has occurred If any of the secure module s tamper sensors are triggered by tampering or by acci...

Страница 183: ...ter The secure key adapter provides both cryptographic coprocessor and cryptographic accelerator functions in a single PCIe card The 4767 002 Cryptographic Coprocessor is suited to applications that require high speed security sensitive RSA acceleration cryptographic operations for data encryption and digital signing Additionally the adapter is useful in secure management use of cryptographic keys...

Страница 184: ...Figure 59 4767 002 Cryptographic Coprocessor Specifications Item Description Adapter FRU number Not applicable I O bus architecture PCIe1 x4 170 Power Systems Managing PCIe adapters ...

Страница 185: ... by cycle Performance Table 31 4767 002 Cryptographic Coprocessor Operation Operation Operations per second AES CBC 128 bit 1KB 7K PK CRT 1024 5K PK CRT 2048 3 5K Key Gen RSA CRT 1024 bit 30 Key Gen RSA CRT 2048 bit 7 Key Gen RSA CRT 4096 bit 0 6 Key Gen ECC BP 192 750 Operating system or partition requirements If you are installing a new feature ensure that you have the software that is required ...

Страница 186: ...ts have little connector type LC and utilize shortwave laser optics The adapter operates at link speeds of 4 8 and 16 Gbps and will automatically negotiate to the highest speed possible LEDs on each port provide information on the status and link speed of the port The adapter connects to a Fibre Channel switch at 4 Gb 8 Gb or 16 Gb It can directly attach to a device without a switch at 16 Gb Attac...

Страница 187: ...igh speed static random access memory SRAM memory Provides ECC protection of local memory that includes single bit correction and double bit protection Provides an embedded shortwave optical connection with diagnostics capability Provides support for an on board context management by firmware Up to 8192 FC port logins I O multiplexing down to the Fibre Channel frame level Provides data buffers cap...

Страница 188: ...Figure 60 PCIe3 16 Gb 2 port Fibre Channel adapter FC EL43 and EN0B 174 Power Systems Managing PCIe adapters ...

Страница 189: ...h the card and can also be purchased from IBM I O bus architecture PCIe base and CEM 3 0 x8 PCIe bus interface Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V 12 V Form factor Sho...

Страница 190: ...46 71 ft 0 5 400 m 1 64 1312 34 ft 8 Gbps 0 5 21 m 1 64 68 89 ft 0 5 50 m 1 64 164 04 ft 0 5 150 m 1 64 492 12 ft 0 5 190 m 1 64 623 36 ft 16 Gbps 0 5 15 m 1 64 49 21 ft 0 5 35 m 1 64 114 82 ft 0 5 100 m 1 64 328 08 ft 0 5 125 m 1 64 410 10 ft Adapter LED states Green and yellow LEDs can be seen through openings in the mounting bracket of the adapter Green indicates firmware operation and yellow s...

Страница 191: ...ling a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and partition requirements see one of the following topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm co...

Страница 192: ...al port Each logical connection has its own resources and the ability to be managed independently Each port provides single initiator capability over a fiber link or provides multiple initiator capability with N_Port ID Virtualization NPIV The ports are connected by using LC type connectors These connectors use shortwave laser optics The adapter operates at link speeds of 2 4 and 8 gigabits per se...

Страница 193: ...ws the supported distances for the different fiber optic cable types at different link speeds Table 35 Supported distances for multimode fiber optic cables Header Cable Type and Distance Rate OM1 OM2 OM3 2 125 Gbps 0 5 meters to 150 meters 1 64 feet to 492 12 feet 0 5 meters to 300 meters 1 64 feet to 984 25 feet 0 5 meters to 500 meters 1 64 feet to 1640 41 feet 4 25 Gbps 0 5 meters to 70 meters ...

Страница 194: ...oaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags info LinuxAlerts html Adapter LED Table 36 LED States Hardware State Yellow LED 8 Gbps Green LED 4 Gbps Amber LED 2 Gbps Comments Power Off Off Off Off Power On before firmwa...

Страница 195: ...rgence enhanced Ethernet CEE switches The link aggregation and failover features of the adapter make it suitable for critical network applications that require redundancy and high availability Important There is no FCoE support on POWER9 systems The four port adapter provides two 10 Gb FCoE small form factor pluggable SFP SR optical ports and two 1 Gb RJ45 Ethernet ports The two 10 Gb FCoE ports a...

Страница 196: ...Figure 63 PCIe3 4 port 2x10 Gb FCoE 2x1 GbE SFP full hight adapter FC EL56 and FC EN0H 182 Power Systems Managing PCIe adapters ...

Страница 197: ...connector Note These wrap plugs are not included with the card 12R9314 FC ECW0 is the only wrap plug that can be purchased from IBM I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system yo...

Страница 198: ...Express PCIe generation 3 adapter The adapter has four ports and is a Fibre Channel over Ethernet FCoE converged network adapter CNA This adapter provides a PCIe 3 0 host bus interface The adapter is a high performance adapter that consolidates traffic for networking and Fibre Channel storage The adapter is optimized for cloud computing virtualization storage and other data center applications The...

Страница 199: ... 10 Gb SFP ports can function in the NIC or FCoE mode The adapter supports the SR IOV Single Root I O Virtualization NIC capability The adapter can function as a Boot adapter Figure 65 PCIe3 4 port 10 Gb FCoE and 1 GbE Copper and RJ45 Adapter Managing PCIe adapters 185 ...

Страница 200: ... Wrap plug FRU number 74Y7010 10N7405 Note These wrap plugs are not included with the card 12R9314 FC ECW0 is the only wrap plug that can be purchased from IBM I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement ...

Страница 201: ...equirements Note These cables are EMC Class A compliant See Table 37 on page 187 for details about the feature codes Figure 67 Top and bottom view of the cable Table 37 Feature code CCIN and part number for varying lengths of the cable Cable length Feature code CCIN Part number 1 m 3 28 ft EN01 EF01 46K6182 3 m 9 84 ft EN02 EF02 46K6183 5 m 16 4 ft EN03 EF03 46K6184 Operating system or partition r...

Страница 202: ...igh performance adapter that consolidates traffic for networking and Fibre Channel storage The adapter is optimized for cloud computing virtualization storage and other data center applications Both the FCoE and network interface controller NIC functions are available for all the four ports Use of the FCoE requires that you use convergence enhanced Ethernet CEE switches The link aggregation and fa...

Страница 203: ...10N7405 Note These wrap plugs are not included with the card 12R9314 FC ECW0 is the only wrap plug that can be purchased from IBM I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you ...

Страница 204: ...for details about the feature codes Figure 69 Top and bottom view of the cable Table 38 Feature code CCIN and part number for varying lengths of the cable Cable length Feature code CCIN Part number 1 m 3 28 ft EN01 EF01 46K6182 3 m 9 84 ft EN02 EF02 46K6183 5 m 16 4 ft EN03 EF03 46K6184 Operating system or partition requirements If you are installing a new feature ensure that you have the software...

Страница 205: ...ata center applications Both the FCoE and network interface controller NIC functions are available for all the four ports Use of the FCoE requires that you use convergence enhanced Ethernet CEE switches The link aggregation and failover features of the adapter make it suitable for critical network applications that require redundancy and high availability Important There is no FCoE support on POWE...

Страница 206: ...Figure 70 PCIe3 4 port 10 Gb FCoE and 1 GbE LR and RJ45 adapter FC EN0M 192 Power Systems Managing PCIe adapters ...

Страница 207: ...plug FRU number 12R9314 for Fibre LC connector 10N7405 Note These wrap plugs are not included with the card 12R9314 FC ECW0 is the only wrap plug that can be purchased from IBM I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_...

Страница 208: ...BM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags info LinuxAlerts html PCIe2 4 port 10 Gb 1 GbE SR Copper SFP RJ45 adapter FC EN0S FC EN0T FC EN0U and FC EN0V CCIN 2CC3 Learn about the specifications and operating system requirements for t...

Страница 209: ...zation The adapter supports dual port operation in any PCIe4 or PCIe3 slot The adapter supports auto negotiation full duplex only The adapter supports multiple media access control MAC per interface The adapter supports integrated media access control MAC and physical layer PHY The adapter supports the following standards for the different ports and functions IEEE 802 3ae in the 10 GbE ports 802 3...

Страница 210: ...e2 4 Port 10 Gb 1 GbE SR Copper SFP RJ45 adapter FC EN0S and FC EN0U Note The ports are numbered from top to bottom as T1 T2 and so on for the AIX and IBM i operating systems 196 Power Systems Managing PCIe adapters ...

Страница 211: ...tem Description Adapter FRU number 00E2715 Designed to comply with RoHS requirement Regular height tailstock part number 00E2863 Low profile tailstock part number 00E2720 Wrap plug FRU number 12R9314 SFP SR wrap plug 10N7405 1 Gb UTP wrap plug Note These wrap plugs are not included with the card 12R9314 FC ECW0 is the only wrap plug that can be purchased from IBM I O bus architecture PCIe2 x8 Mana...

Страница 212: ...ters to 33 meters 1 64 feet to 108 26 feet 0 5 meters to 82 meters 1 64 feet to 269 02 feet 0 5 meters to 300 meters 1 64 feet to 984 25 feet Operating system or partition requirements If you are installing a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices F...

Страница 213: ...he NIC mode The adapter can be used as the host local area network LAN adapter The adapter supports interrupt moderation to deliver increased performance while significantly reducing processor utilization The adapter supports dual port operation in any PCIe3 or PCIe2 slot The adapter supports auto negotiation full duplex only The adapter supports multiple media access control MAC per interface The...

Страница 214: ...Figure 74 PCIe2 2 port 10 GbE BaseT RJ45 adapter FC EL55 or FC EN0W Figure 75 PCIe2 LP 2 port 10 GbE BaseT RJ45 adapter FC EL3Z or FC EN0X 200 Power Systems Managing PCIe adapters ...

Страница 215: ...ne of the following topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or I...

Страница 216: ...e adapter operates at link speeds of 2 4 and 8 gigabits per second Gbps and automatically negotiates to the highest speed possible LEDs on each port provide information about the connection status and link speed of the port The adapter connects to a Fibre Channel switch The LEDs on the adapter indicate the TX RX and link status as shown in Table 41 on page 202 Figure 76 on page 202 shows the adapt...

Страница 217: ...me Specifications Item Description Adapter FRU number 74Y3923 Designed to comply with RoHS requirement Wrap plug FRU number 12R9314 Note The wrap plug is included with the card and can also be purchased from IBM I O bus architecture PCIe2 0 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com suppor...

Страница 218: ...pport the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and partition requirements see one of the following topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm co...

Страница 219: ... connects to a Fibre Channel switch Figure 77 PCIe2 FH 4 port 8 Gb Fibre Channel Adapter Specifications Item Description Adapter FRU number 00WT107 Designed to comply with RoHS requirement I O bus architecture PCIe2 0 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER...

Страница 220: ...4 25 Gbps 0 5 meters to 70 meters 1 64 feet to 229 65 feet 0 5 meters to 150 meters 1 64 feet to 492 12 feet 0 5 meters to 380 meters 1 64 feet to 1246 71 feet 8 5 Gbps 0 5 meters to 21 meters 1 64 feet to 68 89 feet 0 5 meters to 50 meters 1 64 feet to 164 04 feet 0 5 meters to 150 meters 1 64 feet to 492 12 feet Operating system or partition requirements If you are installing a new feature ensur...

Страница 221: ...des the following features Four 10 Gb ports that can function in the NIC mode AIX Network Installation Management NIM support The adapter supports interrupt moderation to deliver increased performance while significantly reducing processor utilization The adapter supports multiple media access control MAC per interface The adapter supports integrated media access control MAC and physical layer PHY...

Страница 222: ...e wrap plug is not included with the card but can be purchased from IBM I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Cables See Cables on page 209 for details 2...

Страница 223: ...meters 1 64 feet to 269 02 feet 0 5 meters to 300 meters 1 64 feet to 984 25 feet Adapter LED Green and yellow LEDs can be seen through openings in the mounting bracket of the adapter The green LED indicates link activity and the yellow LED signifies the link state Table 45 on page 209 summarizes the LED states for this adapter Table 45 LED states Green LED Yellow LED State Off Off No Power or Nor...

Страница 224: ... page 212 for details The adapter supports the Ethernet network interface controller NIC function and also provides SR IOV NIC support SR IOV capability for the NIC function is supported with the appropriate firmware and operating system level for any of the four ports Enabling the SR IOV function requires an HMC The adapter provides the following features Four 10 Gb ports that can function in the...

Страница 225: ...number 00ND463 Designed to comply with RoHS requirement Full height tailstock part number 00ND465 Wrap plug FRU number 74Y7010 Twinax wrap plug I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select t...

Страница 226: ... on page 212 for details about the feature codes Figure 80 Top and bottom view of the cable Table 46 Feature code CCIN and part number for varying lengths of the cable Cable length Feature code CCIN Part number 1 m 3 28 ft EN01 EF01 46K6182 3 m 9 84 ft EN02 EF02 46K6183 5 m 16 4 ft EN03 EF03 46K6184 Operating system or partition requirements If you are installing a new feature ensure that you have...

Страница 227: ...lid state drive FC ES14 Learn about the specifications and operating system requirements for the feature code FC ES14 adapter Overview The NVMe 400 GB mainstream solid state drive FC ES14 is formatted in 4096 byte sectors 4k The drive is mounted in the PCIe NVMe carrier card with two M 2 sockets FC EC59 Driver Write per day DWPD rating is 1 calculated over a 5 year period Approximately 1 095 TB of...

Страница 228: ...x8 2 port Fibre Channel 32 Gb s FC EN1A EN1B EL5U and EL5V CCIN 578F Learn about the specifications and operating system requirements for feature code FC EN1A EN1B EL5U and EL5V adapters Overview FC EN1A EN1B EL5V and EL5U are electronically identical FCs EN1A and EL5U are full height adapters and FCs EN1B and EL5V are low profile adapters The PCIe3 x8 2 port Fibre Channel 32 Gb s Adapter is a PCI...

Страница 229: ...s architecture PCIe3 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V 12 V Form factor Short low profile Managing PCIe adapters 215 ...

Страница 230: ...rts html PCIe3 x8 4 port Fibre Channel 16 Gb s FC EL5W EL5X EN1C and EN1D CCIN 578E Learn about the specifications and operating system requirements for feature code FCs EL5W EL5X EN1C and EN1D EL5X adapters Overview The FC EN1C EL5W and EN1D EL5X are electronically identical FC EN1C EL5W is a full height adapter and FC EN1D EL5X is a low profile adapter The PCIe3 x8 4 port fibre Channel 16 Gb s A...

Страница 231: ...HS requirement 12R9314 I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Managing PCIe adapters 217 ...

Страница 232: ... that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and partition requirements see one of the following topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support customercare ip...

Страница 233: ...uct s and or the program s described in this publication at any time without notice Any references in this information to non IBM websites are provided for convenience only and do not in any manner serve as an endorsement of those websites The materials at those websites are not part of the materials for this IBM product and use of those websites is at your own risk IBM may use or distribute any o...

Страница 234: ...ision to use information technology content successfully Overview The IBM Power Systems servers include the following major accessibility features Keyboard only operation Operations that use a screen reader The IBM Power Systems servers use the latest W3C Standard WAI ARIA 1 0 www w3 org TR wai aria to ensure compliance with US Section 508 www access board gov guidelines and standards communicatio...

Страница 235: ...loyed for this Software Offering provide you as the customer the ability to collect personally identifiable information from end users via cookies and other technologies you should seek your own legal advice about any laws applicable to such data collection including any requirements for notice and consent For more information about the use of various technologies including cookies for these purpo...

Страница 236: ...anforderungen der EU Richtlinie 2014 30 EU zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU Mitgliedsstaatenund hält die Grenzwerte der EN 55022 EN 55032 Klasse A ein Um dieses sicherzustellen sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden ...

Страница 237: ...relle Informationen Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 EN 55032 Klasse A Japan Electronics and Information Technology Industries Association JEITA Notice This statement applies to products less than or equal to 20 A per phase This statement applies to products greater than 20 A single phase This statement applies to products greater than 20 A per phase three phase...

Страница 238: ...e with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits Proper cables and connectors are av...

Страница 239: ...ichtlinie zur Elektromagnetischen Verträglichkeit Dieses Produkt entspricht den Schutzanforderungen der EU Richtlinie 2014 30 EU zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU Mitgliedsstaatenund hält die Grenzwerte der EN 55022 EN 55032 Klasse B ein Um dieses sicherzustellen sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu bet...

Страница 240: ...5024 und EN 55032 Klasse B Japan Electronics and Information Technology Industries Association JEITA Notice This statement applies to products less than or equal to 20 A per phase This statement applies to products greater than 20 A single phase This statement applies to products greater than 20 A per phase three phase Japan Voluntary Control Council for Interference VCCI Notice 226 Power Systems ...

Страница 241: ...o or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference ...

Страница 242: ...st or as determined by IBM the above instructions are not being properly followed You may not download export or re export this information except in full compliance with all applicable laws and regulations including all United States export laws and regulations IBM MAKES NO GUARANTEE ABOUT THE CONTENT OF THESE PUBLICATIONS THE PUBLICATIONS ARE PROVIDED AS IS AND WITHOUT WARRANTY OF ANY KIND EITHE...

Страница 243: ......

Страница 244: ...IBM ...

Отзывы: