PCIe3 x8 SAS RAID internal adapter 6 Gb (FC EJ1C and FC EJ1E; CCIN 57D7)
Learn about the specifications and operating system requirements for the PCIe3 x8 SAS RAID internal
adapter 6Gb (CCIN 57D7) that is integrated with the storage backplane (FC EJ1C) in the 9009-41A,
9009-42A, or 9223-42H. Adding of another PCIe3 x8 SAS RAID internal adapter 6Gb (FC EJ1E) enables
the storage backplane to be configured as a split storage backplane in the 9009-41A, 9009-42A, or
9223-42H.
Overview
The PCIe3 x8 SAS RAID internal adapter 6 Gb is an internal PCI Express generation-3 (PCIe3), serial-
attached SCSI (SAS) Random Array of Independent Disks (RAID) adapter that is integrated in the
9009-41A, 9009-42A, or 9223-42H. The PCIe3 x8 SAS RAID internal adapter 6 Gb is part of a composite
feature of the storage backplane FC EJ1C. The adapter contains the SAS RAID controller. The PCIe3 x8
SAS RAID internal adapter 6 Gb is preinstalled in the dedicated internal PCIe3, x8 slot P1-C49 in the
9009-41A, 9009-42A, or 9223-42H. The internal adapter has a data read or write speed of 6 Gbps. The
PCIe3 x8 SAS RAID internal adapter 6 Gb does not have a write cache.
Single adapter configuration
This configuration of the storage backplane in the 9009-41A, 9009-42A, or 9223-42H with one PCIe3 x8
SAS RAID internal adapter 6 Gb supports 12 numbers of 2.5 inches, small form-factor (SFF) hard disk
drives (HDDs), or solid-state drives (SSDs). FC EJ1C also supports a slim DVD bay. The PCIe3 x8 SAS
RAID internal adapter 6 Gb supports the drives to be used as just-a-bunch of disks (JBOD) or as a RAID.
The supported RAID is RAID 0, 5, 6, and 10. Two mini-SAS HD cables connect the PCIe3 x8 SAS RAID
internal adapter 6 Gb to the two SAS ports on the storage backplane. This configuration with one PCIe3
x8 SAS RAID internal adapter 6 Gb does not split the disks in the storage backplane.
Two adapters split storage backplane configuration
To enable the split storage backplane, another PCIe3 x8 SAS RAID internal adapter 6 Gb (FC EJ1E) must
be installed in the other dedicated internal PCIe3 x8 slot P1-C50. The same backplane as in FC EJ1C is
used in the split storage backplane configuration. The two mini-SAS HD cables connect each of the PCIe3
x8 SAS RAID internal adapter 6 Gb to the two SAS ports on the storage backplane. The 12 drives are then
split into two sets of six drives (HDDs or SSDs), each controlled by one PCIe3 x8 SAS RAID internal
adapter 6 Gb. The split storage backplane configuration supports the drives to be used as just-a-bunch of
disks (JBOD) or as a RAID. The supported RAID is RAID 0, 5, 6, and 10. The PCIe3 x8 SAS RAID internal
adapter 6 Gb in slot P1-C49 controls the slim DVD bay. The split storage backplane does not support the
mixing of HDDs and SSDs in the same RAID set.
154 Power Systems: Managing PCIe adapters
Содержание 00E2714
Страница 4: ...iv ...
Страница 14: ...xiv Power Systems Managing PCIe adapters ...
Страница 74: ...Figure 6 PCIe 8 Gb 2 Port Fibre Channel adapter FC 5273 and FC EL2N 60 Power Systems Managing PCIe adapters ...
Страница 79: ...Figure 8 PCIe 4 port Async EIA 232 1X adapter Managing PCIe adapters 65 ...
Страница 92: ...Figure 14 PCIe3 LP 2 port 10 Gb NIC RoCE SR Cu Adapter FC EC2R 78 Power Systems Managing PCIe adapters ...
Страница 96: ...Figure 16 PCIe3 LP 2 port 25 10 Gb NIC RoCE SFP28 Adapter FC EC2T 82 Power Systems Managing PCIe adapters ...
Страница 101: ...Figure 18 PCIe3 LP 2 port 10 GbE NIC RoCE SFP copper adapter FC EC37 and FC EL3X Managing PCIe adapters 87 ...
Страница 105: ...Figure 21 PCIe3 LP 2 port 40 GbE NIC RoCE QSFP adapter FC EC3A Managing PCIe adapters 91 ...
Страница 136: ...Figure 37 2 port 100 GbE RoCE En Connectx 5 Gen4 PCIe x16 adapter FC EC66 122 Power Systems Managing PCIe adapters ...
Страница 188: ...Figure 60 PCIe3 16 Gb 2 port Fibre Channel adapter FC EL43 and EN0B 174 Power Systems Managing PCIe adapters ...
Страница 206: ...Figure 70 PCIe3 4 port 10 Gb FCoE and 1 GbE LR and RJ45 adapter FC EN0M 192 Power Systems Managing PCIe adapters ...
Страница 243: ......
Страница 244: ...IBM ...