background image

Once

IBCconnect

is installed on your device, you need to change some of the settings. This may

vary slightly depending on the device and the version of iOS your device is using.

3. In the main iPhone

Settings

, select

Cellular

.

4. Locate

IBCconnect

under

Cellular Data

, and set to

Off

.

Optionally, in the main iPhone settings, select

IBCconnect

app, and then go to

Siri & Search

and set

Search & Siri Suggestions

to

Off

. See the next section for WiFi connection.

3.6.2 Using the app to connect to IBC's AHU WiFi

Once you've loaded the IBCconnect app onto your mobile or tablet, you will need to establish a
connection between the IBCconnect app and the IBC air handler. IBC's AHU has a WiFi access point
built into it. Your device needs to be connected to IBC's AHU WiFi point before the app can be used to
control or monitor IBC's air handler. This is done through the app's WiFi network settings.

3.6.2.1 Connecting an Android device

The following instructions may vary slightly depending on the device being used.

1.

Open the

IBCconnect

app.

The WiFi connection of the device is displayed. If the WiFi connection is not IBC-AHU, a WiFi
SETTINGS button is displayed. Tap the WiFi SETTINGS button.

The WiFi network screen appears. The IBC-AHU will appear in the device’s list of WiFi available
networks as "IBC-AHU-xxxxx", where "xxxxx" is the serial number of the controller in the IBC-
AHU.

51

3.6.2 Using the app to connect to IBC's AHU WiFi

Содержание AHU Series

Страница 1: ...INSTALLATION OPERATING MANUAL Air Handling appliances AHU 800 AHU1200 AHU 1600...

Страница 2: ......

Страница 3: ...New construction 19 2 1 4 Mobile home 19 2 1 5 Closet 20 2 1 6 Garage 20 2 1 7 Serviceability 21 2 2 Positioning and mounting the appliance 21 2 2 1 Return air openings for ducting 21 2 2 2 Positioni...

Страница 4: ...eze Protection Mode 48 3 5 LED status indicators 49 Built in diagnostics feature 49 3 6 Operating the appliance with a mobile app 50 3 6 1 Loading IBCconnect 50 3 6 2 Using the app to connect to IBC s...

Страница 5: ...5 3 Fault Codes 67 Air handling appliance parts diagram 70 3...

Страница 6: ...This page is intentionally left blank...

Страница 7: ...e gas supplier from a phone located remotely Follow the gas supplier s instructions or if the supplier is unavailable contact the fire department Warning Improper installation adjustment alteration se...

Страница 8: ...re reference When using electrical appliances follow safety precautions to reduce the risk of fire electric shock or injury to persons including Install or locate the air handling appliance only in ac...

Страница 9: ...h inches 16 19 6 23 Supply air opening depth inches 19 6 Side return air opening height inches 7 10 5 13 Side return air opening width inches 23 Bottom return air opening width inches 13 10 5 14 Botto...

Страница 10: ...1 MBH 22 6 MBH 23 7 MBH Table 1 Heating Capacity rating at 800 scfm cubic feet minute AHU 800 AHU 1200 Heating Capacity Entering Dry Bulb Temperature 70 F 1200 CFM Entering Water Temperature 3 GPM 4 G...

Страница 11: ...71 C 69 1 MBH 76 1 MBH 80 8 MBH 150 F 66 C 61 2 MBH 67 4 MBH 71 6 MBH 140 F 60 C 53 3 MBH 58 8 MBH 62 5 MBH 130 F 54 C 45 5 MBH 50 2 MBH 53 4 MBH 120 F 49 C 37 7 MBH 41 6 MBH 44 3 MBH 110 F 43 C 30 MB...

Страница 12: ...Figure 3 Top supply air opening Figure 4 Bottom return air opening Figure 5 Left side return air opening Figure 6 Right side return air opening 10 Section Specifications...

Страница 13: ...Dimensions for the AHU 1200 model Figure 7 Supply and return air boiler supply and return Figure 8 Frontal view Figure 9 Top view Figure 10 Bottom view 11 Dimensions for the AHU 1200 model...

Страница 14: ...Left side return air opening Figure 12 Right side return air opening Dimensions for the AHU 1600 model Figure 13 Supply and return air boiler supply and return Figure 14 Frontal view 12 Section Speci...

Страница 15: ...Figure 15 Top view Figure 16 Bottom view Figure 17 Left side return air opening Figure 18 Right side return air opening 13 Dimensions for the AHU 1600 model...

Страница 16: ...Stage 2 Thermostat connects R to W2 for second stage heating Y1 Cooling Stage 1 Thermostat connects R to Y1 for first stage cooling Y2 Cooling Stage 2 Thermostat connects R to Y2 for second stage coo...

Страница 17: ...fier 24VAC powered Closes to activate the de humidifier DEH De humidifier OpenTherm OpenTherm Master To X 13 1 2 on boiler IBC SFC SFB series The air handling appliance master communicates to controls...

Страница 18: ...This page is intentionally left blank...

Страница 19: ...information on mounting positions and sizing see Cabinet and air supply dimensions on page 9 Appliances installed with a right side air opening will require the air filter position to be modified For...

Страница 20: ...thermostat capable WiFi connection for programming with the IBCconnect mobile app Sensors for protection and operation Included sensors for supply air return air supply water return water humidifier d...

Страница 21: ...aled with a tape designed for this purpose 2 1 2 Un conditioned space If locating the appliance in an un conditioned space protect the hydronic coil from freezing conditions Propylene glycol may be re...

Страница 22: ...tom 0 0 if no connection C Front 1 24 A Back 0 0 Table 4 Recommended minimum clearance for combustibles and servicing 2 1 6 Garage Garage installations must be in a fully enclosed garage The appliance...

Страница 23: ...the appliance Ensure that You install the air handling appliance level and plumb If the appliance is sitting on the floor shim as needed to level the appliance If the appliance is suspended it is sec...

Страница 24: ...appliance so the air flows in a vertical up flow or down flow direction or in a horizontal left or right direction Figure 23 Upflow installation Figure 24 Downflow installation Figure 25 Left side in...

Страница 25: ...ow Figure 28 Heat pump cased coil on the bottom of the appliance on the return side upflow 2 2 4 Mounting an appliance on the wall Mount the appliance with a pair of field supplied wall brackets Figur...

Страница 26: ...ht return air supply orientation for ducting you will need to reposition the air filter brackets in the opposite position To reposition the filter 1 Remove the two screws from the front cover of the a...

Страница 27: ...ove the wing nuts from the lower right bracket 6 Reposition the top and bottom brackets on the opposite side 7 Slide the filter into the repositioned brackets 25 2 2 5 Repositioning the air filter bra...

Страница 28: ...rding to ASHRAE standards or equivalent Seal all joints and connections to prevent air leakage from the ducting system Choose accessories that will not excessively restrict the air flow and create exc...

Страница 29: ...upply air ducting with a minimum of 1 thick fiberglass insulation with a vapor barrier All insulated joints must be sealed with tape designed for this purpose 2 3 3 Ducting installed in un conditioned...

Страница 30: ...r ensure the piping system is designed to allow the easy removal of air from the boiler piping and easy flushing of the system Copper Pipe Sizing BTU HR Capacity 16 000 BTU 36 000 BTU 1 72 000 BTU 1 1...

Страница 31: ...col feeder field supplied Figure 31 Basic installation boiler water heater with pump Air Handler Coil Head Loss AHU 800 Flow rate gpm 3 4 5 Fluid pressure drop ft water 1 6 2 7 3 5 Table 8 Air handler...

Страница 32: ...the air handling appliance It is equally important to choose the correct circulator 2 5 Connecting the appliance to a tankless water heater Check local codes to ensure that piping the appliance to a t...

Страница 33: ...equired where contaminants are present in the supply water Figure 32 Basic installation with tankless water heater Note The SFT 199 maximum water temperature is 149 F 65 C Ensure that this is hot enou...

Страница 34: ...e ANS NFPA No 70 latest edition or the Canadian Electrical Code C22 1 Part 1 In addition you should refer to the boiler s installation manual The control board diagram below shows the various wiring c...

Страница 35: ...r an external pump and 120VAC line Figure 35 Removing a wire 2 6 2 Connecting line voltage examples for different scenarios This section provides diagrams for wiring a 120 VAC 15 amp supply external P...

Страница 36: ...is preset enabling the W2 blower speed after a preset period of time A jumper between W1 and W2 will initialize this speed without the time delay Figure 36 Single stage heating on demand heat source 3...

Страница 37: ...peed after a preset period of time A jumper between W1 and W2 will initialize this speed without the time delay Optional Figure 37 Single stage heating with fan control on demand heat source 35 2 6 2...

Страница 38: ...the W2 blower speed after a preset time period A jumper between W1 and W2 will initialize this speed without the time delay Optional Figure 38 Single stage heating single stage cooling fan control on...

Страница 39: ...per between W1 and W2 will initialize this speed without the time delay Optional Not used Reversing valve O or B is selectable via the blower control interface Figure 39 Single stage heat pump fan con...

Страница 40: ...uired if boiler does not have an integral pump Dry contact from air handler to boiler enables call for heating Figure 40 Single stage heating from boiler primary secondary piping 38 Section Installati...

Страница 41: ...e an integral pump Dry contact from air handler to boiler enables call for heat Figure 41 Single stage heating with fan control boiler with primary secondary piping 39 2 6 2 Connecting line voltage ex...

Страница 42: ...boiler does not have an integral pump Dry contact from air handler to boiler enables call for heat Figure 42 Single stage heating single stage cooling boiler with primary secondary piping 40 Section I...

Страница 43: ...to create a boiler on command in the HP mode This time delay is initialized after establishing a W1 signal Reversing valve O or B is selectable via the blower control interface Not used Figure 43 Sin...

Страница 44: ...oiler enables call for heat Reversing valve O or B is selectable via the blower control interface W1 heat pump W2 energize TT for boiler removes heat pump Not used Figure 44 Single stage heat pump wit...

Страница 45: ...pump Dry contact from air handler to boiler enables call for heat W1 boiler low fan W2 boiler high fan Not used Figure 45 Two stage cooling with boiler heating 2 stage thermostat 43 2 6 2 Connecting l...

Страница 46: ...ot have an integral pump Dry contact from air handler to boiler enables call for heat W1 boiler low fan W2 boiler high fan Not used Figure 46 Single stage cooling with boiler heating 2 stage thermosta...

Страница 47: ...the appliance or components may need to be replaced Check all line voltage electrical connections to ensure all connections are correct and tight Check thermostat connections Thermostat is in a suita...

Страница 48: ...For fan speed defaults and ranges see the table below AHU Fan speed Operation W1 Heating stage 1 600 CFM Range 300 800 W2 Heating stage 2 800 CFM Range 300 1000 must be than heating stage 1 Y1 Coolin...

Страница 49: ...r Heat 1 to remove the boiler s call for heat Continues to operate the fan for 45 seconds also operates the pump contacts for 30 seconds 3 4 2 Cooling Mode Upon a call for cooling from the thermostat...

Страница 50: ...n Mode Freeze protection mode monitors the return air temperature into the air handling appliance If the internal return air temperature sensor detects a return air temperature below 41 F the air hand...

Страница 51: ...T LED displays a steady state The appliance will not service heat or cooling calls Table 12 Status indicators Built in diagnostics feature The appliance contains a built in diagnostic feature that ena...

Страница 52: ...57 To connect the following setup steps need to be completed 1 Loading the app from the app store Google Play and Apple store 2 Using the app to connect to IBC s AHU WiFi 3 Programming the air handli...

Страница 53: ...en the IBCconnect app and the IBC air handler IBC s AHU has a WiFi access point built into it Your device needs to be connected to IBC s AHU WiFi point before the app can be used to control or monitor...

Страница 54: ...circuit board will start blinking simultaneously in a ON OFF ON OFF OFF OFF pattern when connected 4 Tap the device s back button to return to the IBCconnect app then tap GET STARTED to access the Ho...

Страница 55: ...usly in a ON OFF ON OFF OFF OFF pattern when connected 7 Exit from the Setting screen and open the IBCconnect app again 8 Check your device is connected to the IBC AHU xxxxx WiFi connection This will...

Страница 56: ...enu icon and select Basic Settings 2 Set the Heat Mode and Cool Mode 3 To make adjustments to settings tap menu and then select Advanced Settings We recommend setting Tankless to On in most applicatio...

Страница 57: ...is connected to IBC s AHU WiFi the following screens will display Figure 47 Android mobile showing message device is connected to WiFi Figure 48 iOs mobile showing message device is connected to WiFi...

Страница 58: ...landing page exit the app and then reopen it 1 Tap the GET STARTED button An Android prompt may request that you make your device s location discoverable 2 Tap Allow and then OK to grant permission Th...

Страница 59: ...ntry 4 Tap Forget Network 5 Place the device in Airplane Mode 6 Reconnect the device to the IBC AHU WiFi by selecting the IBC AHU xxxxx from the list of access points Ensure that the WiFi reconnect op...

Страница 60: ...This page is intentionally left blank...

Страница 61: ...and simple maintenance procedures according to IBC s suggested servicing guidelines below Maintenance Required Frequency Check Check and replace filter as needed Replace the filter monthly Inspect sy...

Страница 62: ...install the replacement fan assembly Ensure that you install the fan assembly so that the fan cables can reach the control board that is the cables are positioned towards the front left of the fan ass...

Страница 63: ...ce 1 Remove the two screws from the front cover and set aside 2 Carefully unclip the three cables and lean them away from the hot water coil 3 Remove the nuts and bolts 4 Slide out the fan coil 61 4 2...

Страница 64: ...a scoring knife 3 Place the replacement board on a flat surface and using the knife score a straight line between the main board and the humidity sensor strip The strip should snap off by hand without...

Страница 65: ...door switch and the ground wire connector Now you must use the air handler app IBCconnect to program the model name mode and change default settings if desired 7 To set the model mode and to configur...

Страница 66: ...re the temperature of the sensed environment compared with the value from the measurement of the resistance obtained by connecting a good quality test meter capable of measuring up to 100 k at the con...

Страница 67: ...3 050 35 2 29 996 135 57 2 754 40 4 26 099 140 60 2 490 45 7 22 763 145 63 2 255 50 10 19 900 150 66 2 045 55 13 17 436 155 68 1 857 60 16 15 311 160 71 1 689 65 18 13 474 165 74 1 538 70 21 11 883 17...

Страница 68: ...This page is intentionally left blank...

Страница 69: ...onnect app go to Advanced Settings and check that Pump Enabled is set to on In the IBCconnect app go to Basic Settings and check that Heat Mode is not set to Heat Pump During Stage 1 heat pump heating...

Страница 70: ...fuse Use a meter to check 120V is present on the external connection to the board If 10V is not coming from the fan it is not receiving 120V Check the 10V signal on the web app A C Freeze Freezing det...

Страница 71: ...Error Message Description Possible Fix RTOS Fault 2 Software fault Contact IBC Technical Support for software upgrade Table 14 Warnings and error messages shown on the air handler unit app 69 5 0 Trou...

Страница 72: ...Air handling appliance parts diagram 70 Section Find troubleshooting for IBC Technologies air handling appliances...

Страница 73: ...il 2 ton appliance AHU 800 P 1020 Hot water coil 3 ton appliance AHU 1200 P 1022 Hot water coil 4 ton appliance AHU 1600 170 P 1005 Transformer 40VA 120V 180 P 1001 Control board 190 P 1007 Filter bra...

Страница 74: ...minor edits R2 October 2019 Updated wiring diagrams added LED status indicators and information on using a text file to modify settings in multiple air handlers R3 November Added table of basic defau...

Страница 75: ...77 0277 T 856 877 0544 F 604 877 0295 F 856 735 5584 Toll Free 1 844 HEAT IBC 1 844 432 8422 www ibcboiler com Information in this document is subject to change without notice IBC assumes no responsib...