Please note that the description gives examples for one slave. The description applies
to the second slave as well.
Important note
When connecting a SIMATIC S5 to an ibaBM-DP (in DP-64 mode) via PROFIBUS, e. g.
by an IM308C interface board, you should prevent a data format conflict. Because the
REAL format of S5 does not comply with IEEE standard, the S5-data should be con-
verted on S5-side before being transferred to the PROFIBUS interface!
In compatibility mode 32Mbit or in 32Mbit Flex mode, the data type “S5 FLOAT” is avail-
able.
13.2.1 Modes of Operation Overview
The following table gives an overview of the operating modes which are available on the
device. For each mode you’ll find the appropriate GSD files in the corresponding row.
For more information please refer to the following chapters.
Mode Name
Outputs
Inputs
GSD-file
Application
0
PDA 32 Integers
2 * 32 analog (int)
2 * 32 digital
-
ibaF01n4.gsd
ibaF01n3.gsd
iba_0F01.gsd
ibaPDA, ibaLogic,
SIMATIC S7
system coupling
1*
PDA 32 Reals
2 * 32 analog (real)
2 * 32 digital
-
iba_0F02.gsd
ibaPDA, ibaLogic,
system coupling
no S7
*
)
,
SD
2
n/a
-
-
-
-
3
PDA 28 Reals
2 * 28 analog (real)
2 * 32 digital
-
ibaF04n4.gsd
ibaF04n3.gsd
iba_0F04.gsd
ibaPDA, ibaLogic,
S7,
system coupling
4
n/a
-
-
-
5
INPUT 32 Integers (4 byte reserved)
2 * 32 analog (int)
2 * 32 digital
ibaF00n4.gsd
ibaF00n3.gsd
ibaLogic, S7,
system coupling
6*
INPUT 32 Reals
(4 byte reserved)
2 * 32 analog (real)
2 * 32 digital
iba_0F06.gsd
ibaLogic,
system coupling
no S7
*
)
,
SD
7
INPUT 28 Reals
(4 byte reserved)
2 * 28 analog (real)
2 * 32 digital
ibaF07n4.gsd
ibaF07n3.gsd
ibaLogic, S7,
system coupling
8
IN-OUT 32 Integers 2 * 32 analog (int)
2 * 32 digital
2 * 32 analog (int)
2 * 32 digital
ibaF08n4.gsd
ibaF08n3.gsd
iba_0F08.gsd
ibaLogic, S7,
system coupling
9*
IN-OUT 32 Reals
2 * 32 analog (real)
2 * 32 digital
2 * 32 analog (real)
2 * 32 digital
iba_0F09.gsd
ibaLogic,
system coupling
no S7
*
)
,
SD
A
n/a
-
-
-
-
B
IN-OUT 28 Reals
2 * 28 analog (real)
2 * 32 digital
2 * 28 analog (real)
2 * 32 digital
ibaF0Bn4.gsd
ibaF0Bn3.gsd
ibaLogic, S7
system coupling
* Not applicable to former CPUs SIMATIC S7 (firmware <2.0 for S7-300, firmware < 3.0 for
S7-400) or SIMADYN D