Manual
ibaW-750
18
Issue 1.1
8
System integration
The structure of an ibaW-750-System is always as follows:
ibaW-750 central unit on the left side
Modules (or terminals) of the WAGO I/O System 750 (I/O modules, power supply
modules …), the device supports up to 250 modules.
One end module at the right end of the station to terminate the serial K-bus
Note
Before you integrate the device into your network, inform your IT administrator and ask
for the appropriate procedure.
Notes on device configuration in the network can be found in chapter 9.2.
8.1
System integration with ibaNet-E via Ethernet
Figure 4:
Data acquisition with ibaPDA
ibaW-750 is connected to the ibaPDA computer via a standard Ethernet network. It is not
relevant which of the two Ethernet interfaces is used. The device works with the ibaNet-
E protocol for the transmission of configuration and measurement data.
The network topology is not relevant here. The device can either be connected directly
(P2P) to the ibaPDA computer, as in figure 2, or via a switch or router.
Figure 5:
Connection via external switch
If several ibaW-750 are connected, the switch integrated in the device can also be used.