Manual
ibaPQU-S
24
Issue 1.5
7.6
Voltage supply
7.6.1
Voltage supply X14
The external voltage supply is connected with a 2-pin connector.
Caution!
Only connect the device to an external voltage supply 24 V DC (±10 % unregulated)!
Pay attention to the correct polarity!
7.6.2
Buffer voltage X30
The connection of a buffer voltage is supported at the X30 connector (bottom side). The
following device functions can be buffered when disconnected from power supply:
FO line: incoming ibaNet telegrams are transmitted, the FO line is not interrupted.
For this purpose, a buffer voltage of typ. 12 V DC (9 V …15 V) is applied at the X30
connector. In case of buffering, the current consumption is approx. 70 mA at 12 V.