Make sure that the two slaves are assigned to the correct bus line (bus 0
– con-
nector X40, bus 1
– connector X41). Enter for each slave the slave address, as they
are given in DP project engineering.
Permissible address range: 0 to 125
Note
When setting the value to
„255“, you can deactivate the address of the slave.
Note
Difference to ibaBM-DPM-64
You can enter also station numbers which are not consecutive numbers.
You can separate the two Profibus connectors X40 and X41 by setting switch S6 to
OFF position. Thus, you can measure on 2 different Profibus lines with one DP slave
each.
10.1.4
Administrative Functions
The administrator’s page provides functions for changing passwords and updating
firmware. The page is only ac
cessible for “admin” user.
Figure 11:
Web interface -
Administrator’s page
In area
you can change the password of user „admin“, in area
the one of user
„dpms“ (standard user). For safety reasons the current password must be entered first,
then the new password should be entered twice. The default setting for both passwords
is “dpms”. By means of the corresponding “submit” buttons the new password will be
loaded into the device.