SW-4000T-MCL User Manual (2.0)
Main Functions
- 46 -
LUT (Lookup Table)
Related Setting Items:
The LUT function is used to generate a non-linear mapping between signal values captured on
the sensor and those that are output from the camera. On this camera, you can specify the output
curve using 257 setting points (indexes).
To Use the LUT Function
Configure the settings as follows.
Item
Setting Value /
Selectable Range
Description
LUTSelector
Red, Green, Blue
Select the LUT channel to control.
LUTIndex
0 ~ 256
Select the LUT index to configure. Indexes represent the
possible pixel values captured on the sensor, from the lowest
value (Index 0) to the highest (Index 256).
For example, Index 0 represents a full black pixel and Index 256
represents a full white pixel.
LUTValue
0 ~ 4095
Set the LUT output value for the selected index.
LUT Value
LUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is used to
calculate LUT values between the index points.