Chapter 6 Field Network, PIO, SIO
6.3 Parameter Configuration
6-58
ME0392-4C
6.3.3 Examples of parameter settings at delivery
●
I/O Parameter
NP/PN: PIO
module, CC: CC-Link, CIE: CC-Link IE Field, DV: DeviceNet, EC: EtherCAT, EP: EtherNet/IP, PRT:PROFINET IO, PR: PROFIBUS-DP
No.
Parameter Name
Example of factory setting
Input range Unit
Remarks
NP/PN CC
CIE
DV
EC
EP
PR
PRT
1
I/O port assignment
type
1
0
0
0
0
1
0
1
0 to 20
0: Fixed assignment
1: Automatic assignment
* Priority of I/O port assignment at automatic
assignment
(I/O1
→
PIO unit
•
PIO/SIO unit)
14
Number of Ports Used
for I/O1 Fieldbus
Remote Input
0
64
64
64
256
0
64
0
0 to 1,024
Multiple of 8
15
Number of Ports Used
for I/O1 Fieldbus
Remote Output
0
64
64
64
256
0
64
0
0 to 1,024
Multiple of 8
16 I/O1fix-allocated input
port start No.
-1
0
0
0
0
-1
0
-1
-1 to 3,999
0 + (Multiple of 8) (0 to 299)
1,000 + (Multiple of 8) (1,000 to 3,999)
(Invalid if a negative value is set.)
*1,000 to 3,999 can be set only for Fieldbus
17 I/O1fix-allocated
output port start No.
-1
300
300
300
300
-1
300
-1
-1 to 6,999
300 + (multiple of 8) (300 to 599)
400 + (multiple of 8) (4,000 to 6,999)
(Invalid if a negative value is set.)
*4000 to 6999 can be set only for Fieldbus
18 I/O1 error monitor
1
1
1
1
1
1
1
1
0 to 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power
errors)
3: Monitor (Monitor 24-V I/O power errors)
4: Monitor (Make 24V I/O power errors to
message level)
* 2 to 4 can be set only for PIO
* Some exceptions apply.
20 Input filtering periods
2
2
2
2
2
2
2
2
1 to 9
Input signal is recognized when the status is
held for twice the period set by this parameter.
* Valid only for PIO
120 Network attribute 1
64
1001H
64
1001H
64
1001H
64
1001H
64
1001H
64
1001H
64
1001H
64
1001H
0H to
FFFFFFFFH
Bits 0 to 3: Reserved by the system
Bits 4 to 11: I / O1 Fieldbus link error
confirmation timer value (10ms)
Bits 12 to 15: During PROFINET IO
configuration, registered module
data size type
(0:1 word, 1:4 word)
Bits 16 to 27: Reserved by the system
Bits 28 to 31: Input Port Data Select in I/O1
Fieldbus Link Error
(0: Clear, 1: Hold)
121 Network attribute 2
C8
0000H
C8
0000H
C8
0000H
C8
0000H
C8
0000H
C8
0000H
C8
0000H
C8
0000H
0H to
FFFFFFFFH
Bits 0 to 15: Reserved by the system
Bits 16 to 27: Link timeout value in Fieldbus
initialization (100ms)
Bits 28 to 31: EtherCAT PDO mapping type
(0: Variable,1: 32Byte Fixed)
130
I/O Fieldbus
Own MAC address (H)
0H
0H
0H
0H
0H
0H
0H
0H
0H to
FFFFFFFFH
Only lower two bytes are valid.
131
I/O Fieldbus
Own MAC address (L)
0H
0H
0H
0H
0H
0H
0H
0H
0H to
FFFFFFFFH
132
I/O Fieldbus
Own IP address (H)
192
192
192
192
192
192
192
192
1 to 255
*Setting of “0” and “127” is prohibited.
* Setting establishment not necessary for
PROFINET IO
133
I/O Fieldbus
Own IP address (MH)
168
168
168
168
168
168
168
168
0 to 255
* Setting establishment not necessary for
PROFINET IO
134
I/O Fieldbus
Own IP address (ML)
0
0
0
0
0
0
0
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
135
I/O Fieldbus
Own IP address (L)
1
1
1
1
1
1
1
1
1 to 254
*Setting of “0” and “255” is prohibited.
* Setting establishment not necessary for
PROFINET IO
136
I/O Fieldbus
Subnet mask (H)
255
255
255
255
255
255
255
255
0 to 255
* Setting establishment not necessary for
PROFINET IO
137
I/O Fieldbus
Subnet mask (MH)
255
255
255
255
255
255
255
255
0 to 255
* Setting establishment not necessary for
PROFINET IO
138 I/O Fieldbus
Subnet mask (ML)
255
255
255
255
255
255
255
255
0 to 255
* Setting establishment not necessary for
PROFINET IO
139 I/O Fieldbus
Subnet mask (L)
0
0
0
0
0
0
0
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
140 I/O Fieldbus
Default gateway (H)
0
0
0
0
0
0
0
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
141 I/O Fieldbus
Default gateway (MH)
0
0
0
0
0
0
0
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
142 I/O Fieldbus
Default gateway (ML)
0
0
0
0
0
0
0
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
143 I/O Fieldbus
Default gateway (L)
0
0
0
0
0
0
0
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......