Chapter 1 Specifications Check
33
1.6 Option
1.6.1 Regenerative Resistor Unit
This unit is necessary to be connected in the case that the regenerative energy cannot be
consumed by the regenerative resistor built into the MSCON.
[Specification]
Item
Specifications
RESU-2
(Screw
Attachment Type)
First Unit
RESUD-2
(DIN Rail
Attachment Type)
MSCON Connection Cable
(Model CB-SC-REU010) 1m enclosed
RESU-1
(Screw
Attachment Type)
Model
2nd unit
or later
RESUD-1
(DIN Rail
Attachment Type)
Regenerative unit connection cable
(Model CB-ST-REU010) 1m enclosed
Dimensions
W35.6 × H136 × D115
Body Weight
Approx. 0.7kg
Built-in Regeneration Resistor
220
Ω
80W
[Reference for connectable number of units]
Total Wattage for Motors of 6 Axes
Actuator horizontally
oriented
Actuator vertically oriented
No. of Connected
Regenerative Resistance
Units
to 450
to 200
0
to 900
to 600
1
–
to 800
2
–
to 900
3
Caution : The number of connectable units is a reference for when operation is made
under the following condition;
[Condition] When 1,000mm of back and forth operation is made under the
actuator maximum speed, acceleration/deceleration 0.3G and
rated load with the duty 50%.
In some operational conditions, gateway alarm “0A2 Motor Power Voltage
Error” or “0AB Estimated Regenerative Discharge Power Excess” may be
generated, and it may require more regenerative resistor that described in
the table above. In such cases, add more regenerative resistance units.
However, please note the number of maximum connectable regenerative
resistance units is 4. It is not effective even with connection more than
necessary. Consider to change the operational conditions (to reduce the
load) or to use a higher specification actuator.
ME0306-2A
Содержание MSCON
Страница 1: ...MSCON Controller Instruction Manual Second Edition ...
Страница 2: ......
Страница 4: ...ME0306 2A ...
Страница 8: ...ME0306 2A ...
Страница 20: ...12 ME0306 2A ...
Страница 28: ...20 ME0306 2A ...
Страница 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Страница 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Страница 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Страница 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Страница 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Страница 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Страница 358: ......
Страница 359: ......