IACER BIO EMG Скачать руководство пользователя страница 1

 

USER MANUAL 

MNPG213-00 Edition 14/01/2016 

 

 

 

 

 

 

 

 

 

 

 

 

BIO EMG 

              

  

Read the user manual carefully 

before using the BIO EMG.

 

 

Содержание BIO EMG

Страница 1: ...USER MANUAL MNPG213 00 Edition14 01 2016 BIO EMG Read the user manual carefully before using the BIO EMG...

Страница 2: ...I A C E R S r l 2 MNPG213 00...

Страница 3: ...D USE 6 4 WARNINGS 7 5 MEANING OF THE SYMBOLS ON THE BIO EMG AND IN THE USER MANUAL 8 7 HOW DOES BIO EMG WORK 16 8 MUSCLES TO BE MONITORED POSITION OF ELECTRODES 19 9 CHARGING THE BATTERY 19 10 USING...

Страница 4: ...the force expressed by a muscle muscle group in the same patient at different times In this way you can get an indication on the trend of the force expressed at different times Another application inv...

Страница 5: ...uscles monitored In this way it provides a quantitative support that helps the patient activate individual muscles when his her control ability is limited Functional rehabilitation it helps the patien...

Страница 6: ...centric electrodes for signal reception 1 user manual BIO EMG 3 INTENDED USE The BIO EMG system allows non invasive recording of surface electromyographic signals sEMG received by electrodes placed on...

Страница 7: ...le using surgical equipment shortwave and microwave In mentally impaired patients unless assisted by a professional rehabilitation therapist Whenever the equipment is damaged In the vicinity of flamma...

Страница 8: ...OF THE SYMBOLS ON THE BIO EMG AND IN THE USER MANUAL The four front keys allow the user to completely control the device and all its functions The keys of the instrument allow the user to access and e...

Страница 9: ...ns selection of parameters and setting of desired values Multifunction key that allows you to confirm the selected parameter and open the parameter setting window Multifunction key that allows you to...

Страница 10: ...n threshold for each individual contraction is not exceeded i e 65 of the MVC Target This mode provides maintaining a level of contraction as a percentage of MVC For example 40 of the MVC with a margi...

Страница 11: ...whether you select Relative Feedback Under Threshold A mode rather than the Maintain Target B mode A B FIG 7 2 Relative Feedback function page Under Threshold A Maintain Target B MAIN MENU Ref Contra...

Страница 12: ...ows the Target Error setup page FIG 7 7 to the right shows the channel setup page FIG 7 4 Settings function pages FIG 7 5 Edit Target function page OK OK SETTINGS Channel Settings Edit Target Target E...

Страница 13: ...e settings of each channel Use the arrow keys to select the desired parameter then press the OK button to vary the parameter In particular for every channel you can change the status ON or OFF you can...

Страница 14: ...value can be set from 0 to 98 gradually by 2 The arrow up and arrow down buttons are used to change the value of the target offset The OK button allows you to save the new value and return to the pre...

Страница 15: ...Save Load Settings This feature allows you to save or load previously saved or set parameters FIG 9 9 Page for choosing whether to save or load previously saved or set parameters FIG 9 10 Page with de...

Страница 16: ...d MVC value in using the up and down arrows then press OK 8 Select Target Error and then press OK Use the arrows and to set the desired of error and confirm with OK The smaller the value the more diff...

Страница 17: ...ttings Save Current Settings choose one of Pos 1 Pos 4 and save the desired position with OK Then ESC 2 times to return to the main menu Using the device in UNDER THRESHOLD mode 1 Connect the cable to...

Страница 18: ...peration Then ESC 2 times 9 Select Ref Contraction and press OK and perform the MVC test for the connected muscle or muscles Then ESC 10 Select Relative Feedback and press OK The device starts working...

Страница 19: ...to one or two reception electrodes 9 CHARGING THE BATTERY The battery of BIO EMG can be recharged in two ways using the supplied power adapter and connecting it to the output of BIO EMG in this case t...

Страница 20: ...d in the warnings section BIO EMG should be stored under the following conditions Temperature from 20 C to 40 C Maximum relative humidity 75 Atmospheric pressure from 700 hPa to 1060 hPa Cleaning clea...

Страница 21: ...trodes 3 Check the state of the cables If a cable is damaged replace it 4 Charge the device 12 TECHNICAL FEATURES Manufacturer IACER Srl Italy Model and Type BIO EMG Classification Internally powered...

Страница 22: ...rchasing document otherwise the warranty is not valid 3 The term warranty means exclusively the repair or replacement of components or parts of the equipment that show manufacturing or material defect...

Страница 23: ...I A C E R S r l 23 MNPG213 00...

Страница 24: ...Manufactured and distributed by...