background image

 

USER MANUAL

 

 

 

Bacteria UV 
sterilizer UVC-1

 

 

 

 

1.1

 

Device description

 

1.1.1.

 

The  Device  is  a  household  appliance  used  for  air  disinfection  in 

living areas, offices and industrial premises. In general, the Device is intended 
for use in procedures aimed to decrease the number of pathogens contained 
in  the  air  in  order  to  prevent  diseases.  Operating  principle  is  based  on 
pumping room air through a closed housing of the Device and exposing it to 
ultraviolet (hereinafter referred to as UV). Emission of the built-in UV lamp has 
a  maximum  wavelength  of  253.7  nm  and  destroys  all  types  of  harmful 
microorganisms: bacteria, viruses, molds, fungi, etc.

 

1.1.2.

 

This is an enclosed-type device which operates completely safely 

with 

people 

present.

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
1.3. Device components and supplied package

 

Device components and supplied package are specified in the 
Table 2.

 

Table 1

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
Table 2 

 

 

This  User  Manual  includes  key  features,  operating 

instructions,  intended  use,  maintenance,  repair,  storage  and 
transportation  of  Bacteria  UV  sterilizer  UVC-1  (hereinafter 
referred to as the Device). 

 
Attention!

 

Please  carefully  read  the  present  User  Manual

 

before  using 

the Device. 

Follow the rules, restrictions and instructions contained in this 

User Manual in order to increase the lifespan of the Device and to 
use it more effectively

 

Violation  of  the  storage  instructions  and  operating  rules  will 

lead to manufacturer warranty termination. 

Attention!

 

After transportation during winter period or long storing keep the Device at 

room temperature for two hours before using it.

 

 

1.2

 

Technical features

 

1.2.1.

 

Visual appearance of the Device is shown in the Picture 1.

 

 

 

 
 

 

1.2.2. Technical features are presented in the Table 1. 

 

1.4.

 

Structure and functioning

 

1.4.1.

 

The Device is constructed of a metal housing with polymer or powder 

coating with a built-in UV lamp, start-control devices and a fan for forced air 
circulation. 

There are mounting holes for wall mounting (horizontal or vertical) located on 

the lower side of the housing. 

 

The Device is equipped with a power cord and a power switch on it.

 

1.4.2.

 

Disinfection is conducted by circulating room air through the closed 

housing of  the  Device  and  exposing it to  ultraviolet.  Forced  air circulation is 
provided by the fan.

 

1.4.3.  The UV lamp needs to be replaced after 11000 hours of operation.

 

    

2 INTENDED USE

  

 

2.1    Operating restrictions

 

2.1.1.Do not drop the Device.

 

 

Description

 

Quantity

 

Notice

 

1

 

Bacteria UV sterilizer UVC-1

 

 

1

 

 

2

 

UV lamp

 

1

 

Installed in the Sterilizer

 

3

 

Individual packaging

 

1

 

 

User Manual 

 

Pic. 1

 

1 DEVICE DESCRIPTION AND OPERATION

 

 

Parameter

 

Value

 

Dimensions

 

450х78х72 

mm 
(17.9x3.1x2.9 
in)

 

Weight

 

2.2 kg (4.85 lb)

 

Supply voltage (50 Hz)

 

230±23 V

 

Power consumption

 

15 W

 

Number of UV lamps

 

1

 

Power of UV lamp

 

8 W

 

Type of UV lamp

 

TUV 8w Philips

 

Endurance of UV lamp

 

11000 hours

 

IP Code

 

IP20

 

 