1.1
Device description
1.1.1.
The Device is a household appliance used for air disinfection in
living areas, offices and industrial premises. In general, the Device is intended
for use in procedures aimed to decrease the number of pathogens contained
in the air in order to prevent diseases. Operating principle is based on
pumping room air through a closed housing of the Device and exposing it to
ultraviolet (hereinafter referred to as UV). Emission of the built-in UV lamp has
a maximum wavelength of 253.7 nm and destroys all types of harmful
microorganisms: bacteria, viruses, molds, fungi, etc.
1.1.2.
This is an enclosed-type device which operates completely safely
with
people
present.
1.3. Device components and supplied package
Device components and supplied package are specified in the
Table 2.
Table 1
Table 2
This User Manual includes key features, operating
instructions, intended use, maintenance, repair, storage and
transportation of Bacteria UV sterilizer UVC-1 (hereinafter
referred to as the Device).
Attention!
Please carefully read the present User Manual
before using
the Device.
Follow the rules, restrictions and instructions contained in this
User Manual in order to increase the lifespan of the Device and to
use it more effectively
.
Violation of the storage instructions and operating rules will
lead to manufacturer warranty termination.
Attention!
After transportation during winter period or long storing keep the Device at
room temperature for two hours before using it.
1.2
Technical features
1.2.1.
Visual appearance of the Device is shown in the Picture 1.
1.2.2. Technical features are presented in the Table 1.
1.4.
Structure and functioning
1.4.1.
The Device is constructed of a metal housing with polymer or powder
coating with a built-in UV lamp, start-control devices and a fan for forced air
circulation.
There are mounting holes for wall mounting (horizontal or vertical) located on
the lower side of the housing.
The Device is equipped with a power cord and a power switch on it.
1.4.2.
Disinfection is conducted by circulating room air through the closed
housing of the Device and exposing it to ultraviolet. Forced air circulation is
provided by the fan.
1.4.3. The UV lamp needs to be replaced after 11000 hours of operation.
2 INTENDED USE
2.1 Operating restrictions
2.1.1.Do not drop the Device.
Description
Quantity
Notice
1
Bacteria UV sterilizer UVC-1
1
2
UV lamp
1
Installed in the Sterilizer
3
Individual packaging
1
4
User Manual
1
Pic. 1
1 DEVICE DESCRIPTION AND OPERATION
Parameter
Value
Dimensions
450х78х72
mm
(17.9x3.1x2.9
in)
Weight
2.2 kg (4.85 lb)
Supply voltage (50 Hz)
230±23 V
Power consumption
15 W
Number of UV lamps
1
Power of UV lamp
8 W
Type of UV lamp
TUV 8w Philips
Endurance of UV lamp
11000 hours
IP Code
IP20