i3 International HR16 Скачать руководство пользователя страница 1

ENCODER PARTS AND DEFINITIONS

Quick Installation Guide

16-Channel Encoder

HR16

SAFETY 

When installing your indoor HR16 encoder be sure to avoid:

• 

excessive heat, such as direct sunlight or heating appliances

• 

contaminants such as dust and smoke

• 

strong magnetic fields

• 

sources of powerful electromagnetic radiation such as radios or TV transmitters

• 

moisture and humidity

• 

areas with mechanical vibrations

• 

fluorescent lamps or objects that reflect light

• 

unstable light sources  as this may cause flickering

• 

temperatures below -10° Celsius or 14° Fahrenheit and above 55° Celsius or 131° 

Fahrenheit.

• 

For more details on installation and operation, please refer to the CD 

provided. 

POWER SUPPLY

HR16 Power consumption requirement: 12V DC, max 30W. 

Ensure the supplied voltage meets the power consumption requirements of this encoder 

before powering the encoder on. Incorrect voltage may cause irreparable damage to the 

device and will effectively void the encoder warranty.

PoE power is not supported.

SERVICING

To avoid electrical shock and to preserve the product warranty, DO NOT disasemble the 

encoder. Refer servicing to qualified personnel only.

PACKAGE CONTENTS

Ensure that the items received match those listed on the order form and the packing 

slip. In addition to this manual and a fully assembled encoder, the encoder packing box 

includes:

1.  Rackmount brackets (2 pcs)

2.  SATA flat cables (2 pcs)

3.  HDD Power cable (1 pc)

4.  Round-head screw, black (6 pcs). Use with the rackmount brackets.

5.  Round-head screw, silver (8 pcs). Use to attach the HDD to the inside of the device.

6.  12V DC Power Supply

7.  Power Cable

8.  CAT5 Network cable. Connect HR16 to the Gigabit switch or directly to SRX-Pro Server.

9.  Software CD with Annexxus Configuration Tool

i3-TRNG-CAMS-

HR16-QIG

.indd

Rev. 

151118

1

9

2

3

4

5

6

7

8

10

11

12

13

14

15

16

IN

OUT

AUDIO

LAN

RS-485

12V

D+D-

POWER

VIDEO IN

1

2

4

3

5 6 7

8

2

9

No. Item

Description

1

VIDEO IN

16 x BNC connectors for HDTVI & analog video input

2

USB Port

Universal Serial Bus (USB) port for unit servicing

3

AUDIO IN

Audio Input RCA connector

4

AUDIO OUT

Audio Output RCA connector

5

LAN/Network Port

CAT5 network connection port

6

RS-485 Interface

RS-485 PTZ control connector

7

12V Power Input

12V DC Power Supply connector (inluded)

8

Power Switch

Power switch for turning encoder ON/OFF

9

GND

Ground

INSTALLATION

HR16 encoder is built in a 1U chassis for convenient rackmount installation.

Follow safety precautions when selecting installation location for your HR16 encoder. 

1.  Using supplied screws to secure the provided rack brackets to the HR16 unit, then 

install your HR16 encoder into the server rack.

2.  Make sure the Power Switch is in the OFF position.

3.  Connect your HD-TVI or regular analog inputs to the 16 BNC connectors on the 

encoder. 

Note, that i3 HD-TVI cameras will have two coaxial cables: 720x480 (D1 quality) 

and 1MP/2MP (720P/1080P quality). Make sure you connect the coaxial cable that 

transmit your desired video quality.

4.  Connect your video inputs’ PTZ signal cables (where applicable) to RS-485 block 

on the rear panel of the encoder. Using a pointed object, press and hold the orange 

toggle portion of the 

D+ and D- RS-485 

terminals and insert 

the correct PTZ 

signal cables into the 

slots below. Release 

the orange toggle to 

secure the cables 

in place. Ensure a 

secure and tight 

cable connection.

5.  Connect your Audio IN and OUT devices, if using to the corresponding RCA 

connectors on the rear panel.

6.  Plug in the network cable into the LAN connector on the rear panel of the encoder 

and then plug it into the Gigabit switch.

7.  Connect the provided 12V power supply to the 12V DC Power Supply connector and 

then plug in the supplied Power Cable into the provided power supply.

8.  Plug the power cable into the power source. Use of the UPS (Uninterrupted Power 

Supply) is highly recommended by i3 for added reliability and longevity of your 

encoder.

9.  Return the Power Switch into the ON position. The encoder will power on and the 

front panel LEDs turn on.

1

9

2

3

4

5

6

7

8

10

11

12

13

14

15

16

IN

OUT

AUDIO

LAN

RS-485

12V

D+D-

POWER

VIDEO IN

RS-485

D+D-

Connect to the A+ of PTZ
Connect to the B- of PTZ

CONNECTING HR16 ENCODER TO i3 SRX-PRO SERVER

SRX-Pro Server is capable of supporting up to 2 (two) HR16 encoders.

Each encoder supports up to 16 analog or HD-TVI inputs, however, the number of inputs 

that can be added to the SRX-Pro Server is determined by the number of purchased 

licenses. When purchasing HR16 encoder, make sure to purchase enough “Analog 

Channel” licenses to support all your HD-TVI and analog cameras.

When purchasing HR16 encoder(s) with the DVMS, connect your HR16 to the dedicated 

NIC port(s) on your SRX-Pro Server through a provided CAT5 network cable.

When purchasing HR16 encoder(s) separately from the DVMS, connect your HR16 to an 

i3-recommended Gigabit switch.

LAN

i3 SRX-Pro Server

Via Gigabit Switch

(optional)

i3 SRX-Pro Server

Connection Type 1 (when purchasing together with DVMS):

Connection Type 2 (when purchasing separately from DVMS):

(optional)

CAT5 connection
CAT5 connection

Отзывы: