COBALT Pro

 Wall Sensor 

Standard Operations

101822 / 101675 / 101929 / 101674

I-CON  Systems,  Inc.,  for  product  support  call  1-866-730-7192  or  visit  us  online  at  support.i-con.com                           

One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents

  USER MODE

page 1

Rev 081123

The normal state of the valve. The valve is in user mode when it detects that its cover is on, or if it has been in maintenance mode  

for more than 30 minutes. Auto activations are only available in user mode.

ACTIVATION

Auto-Activation

The valve will automatically flush based on IR detection. The IR sensor has 3 LEDs, a red, green, and blue to indicate detection 

 

and activation status.

When no object is detected no LED indication will display. 

After 5-7 seconds of detecting an object, the valve will be considered “locked on” and a green LED will blink in 5-second intervals 

 

up to 30 seconds. 

When an object exits from lock-on the valve will Auto-Activate.

Manual Activation 

There are two manual activation buttons on the plate. The left button performs a reduced flush, while the right button performs 

 

a standard flush. 

Sentinel Activation 

The valve can automatically activate 24 hours after the last activation, by default Sentinel Activation is off. To toggle Sentinel 

Activation on and off hold down the Activate button in the interface box (not the Manual Activation buttons) for 5 seconds. The 

green LED in the IR sensor window will blink 3 times to indicate it has been turned on, or the red LED will blink 3 times to indicate 

 

it has been turned off. 

Activation Refusal 

When an activation is attempted but the valve is unable to activate, a red LED will flash. This can be caused by obstructions 

 

or being temporarily disabled. Valves are automatically temporarilyy disabled for 3 seconds after activation.

TruFLUSH

®

Pro devices use TruTOUCH®, an algorithm based on water pressure to optimize flush volumes.

  DEFAULT SETTINGS

 

Urinal 

Water Closet

Range

25”

43”

Exit Time

1 second

3 seconds

Water Savings

0%

0%

Base Volume

0.25gpf

1.1gpf

Redetect Time

1 second

15 seconds