1. SAFETY
1.3 CAUTION
2
WARNING!
Before you do electrical work, make sure that there is no voltage in the components of the drive.
WARNING!
To do work on the terminal connections of the drive, disconnect the drive from mains and make sure that the motor
has stopped. Wait 5 minutes before you open the cover of the drive. Then use a measuring device to make sure that
there is no voltage. The terminal connections and the components of the drive are live 5 minutes after it is disconnected
from mains and the motor has stopped.
WARNING!
Before you connect the drive to mains, make sure that the front cover and the cable cover of the drive are closed.
The connections of the AC drive are live when the drive is connected to mains.
WARNING!
Disconnect the motor from the drive if an accidental start can be dangerous. When there is a power-up, a power
brake or a fault reset, the motor starts immediately if the start signal is active, unless the pulse control for
Start/Stop logic is selected. If the parameters, the applications or the software change, the I/O functions (including
the start inputs) can change.
CAUTION!
Do not move the AC drive. Use a fixed installation to prevent damage to the drive.
CAUTION!
Do not make measurements when the AC drive is connected to mains. It can cause damage to the drive.
CAUTION!
Make sure that there is reinforced protective ground connection. It is mandatory, because the touch current of
the AC drives is more than 3.5 mA AC (refer to EN 61800-5-1). See chapter 1.4 Earthing and earth fault protection.
CAUTION!
Do not use spare parts that are not from the manufacturer. Using other spare parts can cause damage to the
drive.
CAUTION!
Do not touch the components on the circuit boards. Static voltage can cause damage to these components.
N800A
Содержание N800 Series
Страница 2: ...ISSUEDATE 2015 06 26 VER 1 ...
Страница 3: ......
Страница 19: ...3 MOUNTING 3 2 2 WALL MOUNTING OF MR5 Fig 3 ThedimensionsoftheACdrive MR5 13 N800A ...
Страница 20: ...3 MOUNTING 3 2 3 WALL MOUNTING OF MR6 Fig 4 ThedimensionsoftheACdrive MR6 14 N800A ...
Страница 21: ...3 MOUNTING 3 2 4 WALL MOUNTING OF MR7 Fig 5 ThedimensionsoftheACdrive MR7 15 N800A ...
Страница 22: ...3 MOUNTING 3 2 5 WALL MOUNTING OF MR8 IP21 AND IP54 Fig 6 ThedimensionsoftheACdrive MR8 IP21andIP54 16 N800A ...
Страница 23: ...3 MOUNTING 3 2 6 WALL MOUNTING OF MR8 IP00 Fig 7 ThedimensionsoftheACdrive MR8 IP00 17 N800A ...
Страница 24: ...3 MOUNTING 3 2 7 WALL MOUNTING OF MR9 IP21 AND IP54 Fig 8 ThedimensionsoftheACdrive MR9 IP21andIP54 18 N800A ...
Страница 29: ...3 MOUNTING 3 3 1 FLANGE MOUNTING OF MR4 Fig 13 ThedimensionsoftheACdrive flangemounting MR4 23 N800A ...
Страница 30: ...3 MOUNTING 3 3 2 FLANGE MOUNTING OF MR5 Fig 14 ThedimensionsoftheACdrive flangemounting MR5 24 N800A ...
Страница 31: ...3 MOUNTING 3 3 3 FLANGE MOUNTING OF MR6 Fig 15 ThedimensionsoftheACdrive flangemounting MR6 25 N800A ...
Страница 32: ...3 MOUNTING 3 3 4 FLANGE MOUNTING OF MR7 Fig 16 ThedimensionsoftheACdrive flangemounting MR7 26 N800A ...
Страница 33: ...3 MOUNTING 3 3 5 FLANGE MOUNTING OF MR8 Fig 17 ThedimensionsoftheACdrive flangemounting MR8 27 N800A ...
Страница 34: ...3 MOUNTING 3 3 6 FLANGE MOUNTING OF MR9 Fig 18 ThedimensionsoftheACdrive flangemounting MR9 28 N800A ...
Страница 52: ...4 POWERCABLING 46 3 Removethecablecover MR8 MR9 N800A ...
Страница 53: ...4 POWERCABLING 47 4 Removethecableentryplate MR8 MR9 N800A ...
Страница 54: ...4 POWERCABLING 48 5 MR9only Loosenthescrewsandremovethesealingplate N800A ...
Страница 55: ...4 POWERCABLING 49 6 RemovetheEMCshieldplate A ThewingnutinMR8 A MR9 N800A ...
Страница 80: ...5 CONTROLUNIT 74 Fig 30 Thegalvanicisolationbarriers A Thecontrolunit B Thepowerunit N800A ...
Страница 84: ...6 COMMISSIONINGANDADDITIONALINSTRUCTIONS 78 3 FindtheEMCjumpersthatconnecttheRFIfilterstoground N800A ...
Страница 101: ......