5.0 

 

To stop the compressor, turn the ignition switch to the OFF position. 

 

 

 
6.0 

 

To determine the correct working pressure and air flow requirements for any piece 

 

 

of equipment check the corresponding manual. 

6.1 

 

Be aware that th

e air flow figure stated on tools and accessories refers to ‘free air 

 

 

delivery’ and not the piston displacement of the compressor. 

6.2 

 

When adjusting the regulator always adjust up to the required pressure. 

6.3 

 

After fitting the desired coupling to the outlet valve, connect an air hose and hook up 

 

 

to an air system. 

 

 

An outlet regulator is necessary to use air equipment direct from the compressor. 

6.4 

 

At the end of each working day, drain any moisture from the main tank. 

6.5 

 

Place a container under the drain plug and then carefully unscrew it anti-clockwise. 

6.6 

 

DO NOT allow moisture to accumulate in the tank as this will corrode the inside of 

 

 

the tank and affect the pressure rating of the tank. 

 
 

 

 

 

 

WARNING

 

 

 

Service and maintenance must be performed by an authorised agent. 

 

 

DO NOT tamper with, or attempt to adjust the pressure switch or safety valve. 

 

 

Before moving or carrying out any maintenance on the compressor make sure that 

 

 

the ignition switch is OFF and the air tank pressure has been vented and the  

 

 

compressor has been allowed to cool down for a period of time.

 

 

 

Failure to carry out maintenance tasks, may invalidate the warranty on your 

 

 

compressor. 

7.0 

 

In order to keep the compressor in good working condition, periodic maintenance 

 

 

is essential. 

 

 

Operations to be carried out after the first 60 hours of use.

 

7.1 

 

Check that all bolts and nuts are tight, particularly those retaining the crank case and 

 

 

cylinder head. 

7.2 

 

Replace the lubricating oil. 

 

 

Operations to be carried out daily.

 

7.3 

 

Drain condensation by opening the valve located under the tank. 

 

       5. STOPPING PROCEDURE 

       6. USING THE MACHINE 

       7. MAINTENANCE 

Содержание HY70100P

Страница 1: ...1...

Страница 2: ...ATION 9 4 STARTING PROCEDURE 10 5 STOPPING PROCEDURE 11 6 USING THE MACHINE 11 7 MAINTENANCE 11 14 8 SPECIFICATION 15 9 TROUBLESHOOTING 16 10 RECYCLING AND PRODUCT DISPOSAL 17 11 DECLARATION OF CONFOR...

Страница 3: ...following warning signs symbols and or PPE pictograms may ap pear throughout this manual You MUST adhere to their warnings Failure to doso may result in personal injury to yourself or those around yo...

Страница 4: ...e 1 14 To avoid carbon monoxide poisoning DO NOT use Petrol Diesel powered equipment inside any of the following Home garage tent camper van mobile home caravan or boat This is not exhaustive and if y...

Страница 5: ...are but not limited to safety gloves overalls 1 33 When fueling de fueling ALWAYS avoid inhaling fumes 1 34 When de fueling ALWAYS use a proper fuel retriever 1 35 ALWAYS carry fuel in the correct an...

Страница 6: ...o another part of your face or body 1 59 Gasses from charging batteries are highly flammable and great care should be taken to charge in well ventilated areas 1 59 1 There is an explosion risk if the...

Страница 7: ...and condition before use If in any doubt do not use the compressor and contact your service agent 2 3 Before moving or maintaining the compressor ensure that the air tank pressure has been vented 2 4...

Страница 8: ...t the compressor is adequately protected 2 24 DO NOT smoke or have any naked flames nearby whilst refuelling 2 25 DO NOT leave the compressor unattended 2 26 DO NOT remove the fuel cap or try to refue...

Страница 9: ...pressor moves whilst in operation 3 5 If the surface is in a raised position make sure the compressor cannot fall securing it in a suitable way 3 6 To ensure good ventilation and efficient cooling the...

Страница 10: ...nap back gently return it 4 4 Once running move the choke to the OFF position 4 5 When the engine is running smoothly the compressor will operate automatically building up the pressure in the tank whi...

Страница 11: ...mulate in the tank as this will corrode the inside of the tank and affect the pressure rating of the tank WARNING Service and maintenance must be performed by an authorised agent DO NOT tamper with or...

Страница 12: ...e frequently in dusty environments 7 10 Remove the air filter element by undoing the screw and removing the filter cover 7 11 Clean the air filter by blowing through from the clean side with an airlin...

Страница 13: ...00 hours 7 19 Change the air filter element 7 20 Replace the pump lubricating oil with an oil suitable for temperatures ranging from 5 C to 45 C viscosity Type 68 compressor oil 7 21 Drain the oil whe...

Страница 14: ...nk Check for oil leaks Check oil levels Check guards and covers Check for noise and vibrations Check for air leaks Clean compressor Clean air filters Check safety release valve Check belt tension Chan...

Страница 15: ...97 Engine Speed rpm 1800 idle Pump Speed rpm 950 Start Method Recoil Maximum Pressure psi bar 145 10 Cut Out Pressure psi bar 87 6 Tank Capacity l 90 Air Displacement free air delivery cfm l min 10 7...

Страница 16: ...r is at idle speed Non return valve seal defective Discharge air tank pressure If problem persists contact your dealer Compressor does not stop at maximum pressure Pressure switch fault Contact your d...

Страница 17: ...ycling centre 10 4 Certain products contain batteries which should not be disposed of in your domestic waste 10 5 You MUST recycle batteries in accordance with your local authority or recycling centre...

Страница 18: ...Type Serial No Petrol Air Compressor Net Installed Power 4 4kW The technical document is kept by Roland Llewellin Genpower Ltd Isaac Way Pembroke Dock Pembrokeshire SA72 4RW The conformity assessment...

Страница 19: ...https hyundaipowerequipment co uk warranty 13 1 For full Warranty Terms Conditions please visit https hyundaipowerequipment co uk support warranty information 14 0 Our manuals are constantly being rev...

Страница 20: ...20...

Отзывы: