PAGE 11
Rev 2
4.26
DO NOT direct the air stream at body. DO NOT direct air stream at persons or animals.
There is a risk of injury, by directing air stream at persons or animals.
4.27
Drain tank. Drain tank daily or after 4 hours of use. Open drain fitting and tilt compressor
to empty accumulated water.
4.28
DO NOT stop compressor by pulling out the plug. Use the "AUTO/OFF" of pressure switch.
4.29
Only use recommended air handling parts acceptable for a pressure not less than 125 Psi
(8.6 Bar). Risk of bursting. Use only recommended air handling parts acceptable for pressures
not less than 125 psi (8.6 bar).
4.30
Replacement parts. When servicing use only identical replacement parts. Repairs should
be conducted only by authorised service centre.
4.31
Grounding (Earthing) instructions.
4.31.1
This compressor should be grounded (earthed) while in use to protect
the operator from electric shock.
4.31.2
The compressor is equipped with a three-conductor lead and three-pin
grounding (earthing) type plug to fit the proper grounding (earthing) type socket.
4.31.3
The green and yellow conductor in the lead is the grounding/earthing wire.
4.31.4
Never connect the green and yellow wire to a live terminal.
4.32
Extension leads.
4.32.1
Use only three-extension leads that have three-pin grounding (earthing) type
plugs and three-pole sockets that accept the compressor’s plug.
4.32.2
Replace or repair damaged lead. Make sure your extension lead is in good
condition. When using an extension lead, be sure to use one heavy enough to carry the current
your product will draw. An undersized lead will cause a drop in line voltage resulting in loss of
power and overheating. Tables below shows the correct size to use depending on lead length
and name plate ampere rating. If in doubt, use the next heavier gauge.
Avoid electrical shock hazard. Never use this compressor with a damaged or frayed electrical
lead or extension lead. Inspect all electrical leads regularly. Never use in near water or in any
environment where electric shock is possible.
Tab.1
SECTION VALID FOR A MAX LENGTH OF 20 mt single-phase
CV
kW
220/230V
mm
2
110/120V
mm
2
0.75 – 1
0.65 – 0.7
1.5
2.5
1.5
1.1
2.5
4
2
1.5
2.5
4 –6
2.5 – 3
1.8 – 2.2
4
/
The diameter of the extension cable of the 3-phase compressors must be in
proportion to its length: see table (tab 2)
Tab. 2
SECTION VALID FOR A MAX LENGTH OF 20 mt three-phase
CV
kW
220/230V
mm
2
380/400V
mm
2
2 – 3 – 4
1.5 – 2.2 – 3
2.5
1.5
5.5
4
4
2
7.5
5.5
6
2.5
10
7.5
10
4
Содержание HY30100
Страница 1: ...ELECTRIC AIR COMPRESSOR Models HY3050 HY30100 HY3150 User Manual...
Страница 5: ...2 UNPACKING USAGE INSTRUCTION PAGE 5 Rev 2...
Страница 6: ...PAGE 6 Rev 2...
Страница 7: ...P AGE7 Rev 2...
Страница 23: ...PAGE 23 Rev 2...