4-12 Inspection, Maintenance and Adjustment
Check fluid level of battery
The battery installed in this machined is the one without need-
ing maintenance, and you need not add electrolyte into the
battery. When the charge indicator is transparent, it indicates
that the electrolyte is less, and the possible reason is leakage or
the faults in charging system. Immediately perform the trouble-
shooting and replace the fault battery. (Fig.5)
Check the charge state
Check the charge state by observing the indicator color set
inside.
●
Green: Normal
●
Black: Charge is inadequate. Check the generator.
●
Transparent: Electrolyte is inadequate. Replace with a new
battery.
Fig 5
Fig6
Check terminals of battery
Ensure the battery is fixed securely. Clean the battery terminals
and battery wire connectors. The soda and water can neutralize
the electrolyte on battery surface, terminals and wire connec-
tors. Coat Vaseline or grease on the connector to prevent the
corrosion.( Fig6)
Replace battery
When the charge indicator is transparent, it is necessary to re-
place the battery. The batteries shall be replaced in pairs.
The mixed-use of new and old battery will shorten the service
life of the new battery