16
HHC315C
5.2 DRAINING THE AIR TANK
WARNING!
ALWAYS use ear and eye protection when draining the air tank,
escaping air may contain moisture and debris.
Condensation will form inside the air tank. Make sure to completely drain condensed
water from the tank after each use to prevent rust and thinning of air tank.
1.
Turn power switch to OFF and unplug the power cord from receptacle.
2.
Open the drain valve and drain all air and condensed water from the air tank.
Tilt tank to remove all moisture.
3.
Once air tank is fully drained, close the drain valve.
5.3 CHECKING FOR AIR LEAKS
WARNING!
Minor leaks may cause the air compressor to overwork which can
result in premature breakdown or lower performance.
1.
Turn power switch to OFF and open drain valve to release all pressure from
the air tank.
2.
Apply a water and soap solution to all air line fittings and connections.
3.
Turn power switch to ON.
4.
If soap bubbles appear or grow on these fittings when compressor reaches
the pressure cut-out limit and the pump turns off, this indicates a leak at that
location.
5.
Turn power switch to OFF.
6.
Tighten or replace leaking fittings and connections