SECTION 4 FUNCTION
Double L N terminal makes it easy for wire loop-in and loop-out, and saves the cost of terminal block and assembly time.
This sensor maybe over-ridden by the end-users to switch on/off the lights manually, or adjust the maximum brightness during motion hold-time with the
push-switch. This makes the product more user-friendly and offers more options to fit for extra-ordinary demands.
* Short push (<1s): on/off function;
ON → OFF: the light turns off immediately and cannot be lighten for a certain time (equals to hold time preset) even there is movement is detected. After
this period, the sensor goes back to auto sensor mode.
OFF → ON: the light turns on 100% and goes to auto sensor mode, even when ambient Lux level exceeds the daylight threshold.
* Long push (>1s): adjust the maximum brightness (between 10% and 100%) during hold-time. Both the settings on DIP switch and manual override can
overwrite each other, the latest action controls.
* If no end-user adjustment is desired, simply leave this terminal disconnected.
4.1 Manual Override
4.2 Loop-in and Loop-out Terminal
SECTION 5 TROUBLE SHOOTING
MALFUNCTION CAUSE REMEDY
CAUSE
REMEDY
The light will not come on
The lamp is always on
Incorrect light-control setting selected
Continuous movement in the detection zone
Faulty lamp
No power supply
Adjust daylight threshold setting
Replace lamp
Check power to sensor
Check detection area setting
Scene mode options [ ]
Note: the end-user can fine tune the settings by pressing buttons of detection range / hold time / stand-by period / stand-by dimming level
/daylight sensor , the last setting will over-write that feature of the pre-set scene.
6
11
13
12
7
zone
4
There are 4 scene modes built into the remote control for different applications:
Scene options Detection range Hold time Stand-by period Stand-by dimming leve
Daylight sensor
SC1 100% 1min 10min 10%
2Lux
SC2 100% 5min 10min 10%
2Lux
SC3 100% 10min 30min 10%
10Lux
SC4 100% 10min + 10%
50Lux
8
Daylight sensor [ ]
Press buttons in zone to set daylight sensor at 2lux / 10lux / 50lux.
13
zone
13