background image

1. Technical Specifications

Installation and Instruction Manual

 

 

2. Installation 

Protocol

4 dBm 

2.4 GHz - 2.483 GHz 

Operation frequency
Transmission power
Range (Typical indoor)
Protocol

10~30m

5.0 SIG Mesh

Stand-by power

Operating voltage

<1.5W

220~240VAC  50/60Hz 

Operation temperature

20% ~ 90%

Relative humidity

Ta: -20

O

C ~ +50

O

C

EMC standard (EMC)

Safety standard (LVD)

Certification

EN55015, EN61000, EN61547

CB, CE , EMC, RED, RCM

EN60669-1/-2-1
AS/NZS60669-1/-2-1

RED

EN300328, EN301489-1/-17

IP20  

IP rating

Free App for set-up and commissioning

3. Download the App

4. Operation

 HBP02

Wire Preparation

0.75 - 4mm

8mm

Rising clamp terminal.

To make or release the wire from the terminal, use a screwdriver 
to push down the button.

35.6

12.1

Ø 56

59

59

Ø 3.4

Ø 6.8

86

N

N
HBP02

L

L

Mechanical Structure & Dimensions

Wiring Diagram

The touch panel HBP02 can keep the time runing for up to 7-8 weeks against power 
failure.

WARM

COOL

DOWN  

UP 

Brightness
Control

Tunable 
White 
Control

Scenes are simply programmed using the App.

Create and name the scenes using the scenes menu, and then assign the
scenes to buttons                        from the device settings menu.

Scene Recall

The ON/OFF button has a configurable response via the App.

   Permanent OFF (Occupancy sensor disabled).

Touch Indications

Real-time Sustainability

Three methods for successful touch indications:
Vibration / Beeper / LED indicator
User can select any one, two or all of them to indicate successful touch on HBP02 in the App.

1

2

3

4

1

2

3

4

Touch Panel with                 5.0 SIG Mesh

HBP02-20210323-A0

Turning off via the ON/OFF button will suspend the entire system, including occupancy sensor. 
Pressing this button again will resume the last automatic profile selected, or pressing any other 
button on the control panel will wake up the system.

5.0 SIG mesh

iOS 10.0 or later

Android 5.0 or later

Web app/platform:

iot.koolmesh.com

86

Senser take over

Press this button to quit manual override mode(Sensors will take over the control).

Clean Mode

Long press this button for more than 5s to go to clean mode (during this clean mode, the touch 
panel screen will be locked and does not respond to any touch), it will quit automatically after 1min.

Отзывы: