background image

Automatic Mode Buttons

                   The Office/Classroom profile may be resumed at anytime by pressing this button.

If manual adjustments are made from the Office/Classroom mode, the user settings will be cancelled and the lighting levels restored 
according to the Office/Classroom profile after the person has left the room (the HBHC25 occupancy sensor times out) and 
automatic mode is resumed.

                   The Healthcare profile may be resumed at anytime by pressing this button.

In Healthcare mode, any manual adjustments are retained until 00:00h (12am), upon which the user settings will be cancelled and 
the Healthcare profile will be automatically resumed.

Operation

1

.

.

4

Classroom

Office/

Healthcare

Ÿ

WARM

COOL

Ÿ

Ÿ

DOWN  

UP 

Ÿ

On/Off

ŸŸ

ŸŸ

1

2

3

4

Office/

Healthcare

Classroom

DOWN                       WARM

UP                             COOL

Brightness
Control

White 
Balance
Control

Scene memories are simply 
programmed using the APP.

Create and name the scenes using 
the scenes menu, then assign the 
scenes to memory buttons 1 - 4 
from the device settings menu.

Scene Memory Recall

The On/off button has a configurable response via the APP.

1) Permanent off (Occupancy sensor disabled).

The off button will suspend the entire system, including occupancy sensor. Pressing this button again will resume the last automatic 
profile selected, or pressing any other button on the control panel will wake up the system according to the button pressed.

2) Temporary off (Occupancy sensor remains active).

Office profile - The off button will turn off the lights and any manual mode settings are cancelled. Automatic mode is resumed 
according to the profile and the lights will turn on again automatically from the occupancy sensor, or according to function from a 
button selection on the HBP01.

Healthcare profile - The off button will turn off the lights and any manual settings will be retained until 00:00h (12am).  Pressing this 
button again before 00:00h will resume the previous lighting levels,as will the lights being turned on via the occupancy sensor.  
Pressing any other button to turn on the system will operate the lights according to function.

Manual Mode Buttons

Night Light

The HBP01 features a night light for convenience. Its operation is fully configurable in the app.

Содержание HBP01

Страница 1: ...ontrol The HBP01 is programmable using the free to download Hytronik APP on both iOS and Android platforms Bluetooth Touch Panel HBP01 EMC standard EMC Safety standard LVD Certification EN55015 EN61000 EN61547 Semko CB CE EMC RED RCM EN60669 AS NZS60669 Safety and EMC Operation temperature Relative humidity Ta 0 O C 50 O C 20 90 Environment IP20 IP rating Office Commercial Lighting Classrooms Hosp...

Страница 2: ...munication distance However we recommend for indoor applications that device placements should be no further apart than 15m S ͽ S Notes The range for which a smart phone can communicate with the lighting points will vary from model to model and is dependant on its capability Other environmental factors as per opposite will influence the ultimate achievable range of communication between smart phon...

Страница 3: ...ne Memory Recall The On off button has a configurable response via the APP 1 Permanent off Occupancy sensor disabled The off button will suspend the entire system including occupancy sensor Pressing this button again will resume the last automatic profile selected or pressing any other button on the control panel will wake up the system according to the button pressed 2 Temporary off Occupancy sen...

Страница 4: ...cell mode set the natural light level at which the keypad backlight turns on off Select disable for always on In timer mode set the times at which the keypad back light turns on off Select Scene assignment Press button 1 4 from the image or the list to open the scenes menu Control assignment Press anywhere in the green highlighted area of the image or manual control from the list to enter this set...

Отзывы: