5.6 Coprocessor Over-Temperature Alarm
5.6.1 Description
When the advanced repeater detects that the temperature of the coprocessor exceeds 110°C, the alarm indicator glows
red and the alarm code H1 appears on the display.
At this time, the repeater fails to work.
5.6.2 Solution
Take an appropriate measure to reduce the temperature lower than 100°C at the coprocessor.
5.7 Network IP Conflict Alarm
5.7.1 Description
When a network IP conflict occurs between the repeater and other network devices in the same network segment, the
alarm indicator glows red and the alarm code H3 appears on the display.
At this time, network services of the repeater are unavailable.
5.7.2 Solution
Check and modify the network configuration.
5.8 Slave Unregistered Alarm
5.8.1 Description
In the IP multisite connect network, if the repeater works as a slave one and fails to send a registration request to the
master repeater due to improper network configuration, the alarm indicator glows red and the alarm code E9 appears
on the display.
At this time, the repeater cannot repeat the signal or data in the IP multisite connect network.
5.8.2 Solution
Check and modify the network configuration.
5.9 Repeater Disabled Alarm
5.9.1 Description
With the Repeater Disable feature enabled by your dealer, when the repeater detects the active level, the alarm indicator