11
5. Alarm Information
With the Alarm feature enabled by your dealer, the repeater can automatically trigger an alarm if it does not work well.
When the alarm is active, the alarm indicator glows red and the alarm code appears on the display.
The following table describes alarms in detail.
Alarm
Code
Alarm Name
Description
E3
Under-voltage alarm
The repeater fails to work. At this time, if the Repeater
Backup feature is enabled on the CPS, the repeater starts a
backup.
E4
TX unlocked alarm
The repeater fails to work. At this time, if the Repeater
Backup feature is enabled on the CPS, the repeater starts a
backup.
E5
RX unlocked alarm
The repeater fails to work. At this time, if the Repeater
Backup feature is enabled on the CPS, the repeater starts a
backup.
E6
Power amplifier (PA) over-temperature
alarm
The repeater fails to work. At this time, if the Repeater
Backup feature is enabled on the CPS, the repeater starts a
backup.
E7
Voltage standing wave ratio (VSWR)
Alarm
The repeater automatically works at lower TX power.
E8
Off-lease alarm
The repeater fails to work.
E9
Slave unregistered alarm
The repeater cannot repeat the signal or data in the IP
multisite connect network.
EE
Repeater disabled alarm
The repeater fails to work.
Eb
Low forward power alarm
The repeater stops transmission.
EH
Over-voltage alarm
The repeater fails to work. At this time, if the Repeater
Backup feature is enabled on the CPS, the repeater starts a