Wiring 115VAC Power
For standard 115VAC power connection:
z
Verify AC power supply wires and low voltage
(12V & 24V accessory power wires) run through
two separate conduits. The higher voltage from
the AC power supply may cause interference
and anomalies in SwingSmart DC operation
if the high and low voltage wires are routed
through the same conduit.
z
Maximum gate operator current draw is 3 Amps
on a dedicated 115VAC circuit (20A dedicated
circuit is recommended).
z
Make sure proper wiring is being used. The
following table shows the maximum allowable
wire run from the power source to the operator
for various wire sizes.
Table 5. Wire Gauge versus Run
AC
Power
14 gauge
wire
12 gauge
wire
10 gauge
wire
One
operator
115V
730 ft
(223 m)
1200 ft
(366 m)
1900 ft
(579 m)
Two
operators
115V
460 ft
(140 m)
750 ft
(228 m)
1160 ft
(354 m)
NOTICE
Table 5 assumes a dedicated circuit with an
accessory power load up to 2A. Additional
loads require that the wire size be increased
or the distance of the run be decreased.
To connect to 115VAC power, take the following
steps:
1.
Make sure the AC power is turned off at its
source and the DC and AC power switches on
the operator are in the off position.
2.
Access the input power wires and service outlet
wires by removing the two Phillips-head screws
that secure the high voltage junction box cover.
See
.
3.
Wire nut or crimp bond the power supply wires
to the black and white lead wires coming from
the AC power switch (no label).
4.
Wire nut or crimp bond the equipment ground
wire to the green ground wire in the junction
box.
5.
To activate the 115VAC service outlet, include
the black and white outlet lead wires and the
green ground wire in the connections made
above.
6.
Neatly organize all wire connections and
replace the high voltage junction box cover.
Secure it with the two Phillips-head screws.
NOTICE
The service outlet wires are solid copper and
are labeled and bound together to keep them
separate from the AC power switch wires.
POWER
41
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018
Содержание SwingSmart DC 20
Страница 2: ...2 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 24: ...SAFETY INFORMATION 24 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 138: ...NOTES 138 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 139: ...NOTES 139 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...