INSTALLATION
ADJUSTING THE LIMIT SWITCHES
1.
Determine whether the gate operator is a
right-hand operator (Figure 11) or left-hand
operator (Figure 12). Stand on the secure side
of the gate. If the gate opens to the right, it is
a right-hand operator.
Figure 11. Right Hand Dual Gate Opening
Figure 12. Left Hand Dual Gate Opening
PUBLIC SIDE
SECURE SIDE
Right Hand OPEN
Left Hand OPEN
PUBLIC SIDE
SECURE SIDE
NOTICE
For a right-hand operator, the OPEN switch is
the left limit switch as shown in Figure 13
opposite occurs in a left-hand operator; the
OPEN switch becomes the right limit switch.
2.
To adjust the limit cams, use a Phillips-head
screwdriver and loosen the fastener that
secures each limit cam to the limit plate.
3.
Manually, open and close the gate. Move
the limit cams so they trip the appropriate
limit switch at the full OPEN and full CLOSE
positions.
4.
Secure the limit cams by retightening the two
Phillipshead screws.
A fin on the limit plate fits into the taper clamp.
This feature ensures the limits always track the
gate arm position even if the gate is struck and
the taper clamp slips.
Figure 13. Lmit Switches
NOTICE
When reassembling the taper clamp, make
sure the limit plate fin is seated into the slot
on the taper clamp.
LIMIT PLATE
LIMIT CAM
LOOSEN
SCREWS
LIMIT
CAM
LIMIT
SWITCHES
34
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018
Содержание SwingSmart DC 20
Страница 2: ...2 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 24: ...SAFETY INFORMATION 24 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 138: ...NOTES 138 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 139: ...NOTES 139 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...