INSTALLATION
PAD CONDITION
Pouring the Concrete
1.
Follow the local building codes to identify the
frost line and determine the required depth
of the concrete pad. HySecurity recommends
a minimum 16-inch (40.6cm) depth with a
minimum 2-inch (51cm) extension above
ground level. Refer to Figure 3
2.
Before pouring the pad, consider conduit
placement so it fits within the confines of the
cutout in the SwingSmart base plate as shown
in Figure 3. Run separate conduits for:
z
high voltage swiring (115/230V supply power)
including equipment ground
z
low voltage wiring (12V and 24V accessory
power) including:
•
vehicle loop control wiring
•
primary/secondary connections
z
earth ground (NEC/NFPA)
3.
Extend conduit height 2-inches (51mm) above
the pad (4-inches/102mm above ground level).
Make sure the concrete forms are square with
the gate and the pad is level. Refer to Figure
for minimum pad dimensions.
NOTICE
SwingSmart provides a 6 x 7-inch (15.2 x
17.7cm) cutout in its chassis base for conduit.
Refer to Figure 3. The design also provides a
9.6-inch (24.4cm) height between the control
box and chassis base for pulling and placement
of wires.
CAUTION
Be sure to restrict conduit to the 6 x 7-inch
(15.2 x 17.7cm) cutout in the chassis base if
you plan to use the extended battery backup
kit. The area designed for the optional dual
50Ah batteries may be obstructed if conduit
is routed elsewhere.
Figure 3. Pad Condition and Dimensions
7.6” (19.3 cm)
6" x 7"
(15.2cm x 17.7cm)
1.8” (4.6cm)
2.5”
(6.3 cm)
2.8”
(7.1 cm)
20” COVER
(50.8 cm)
1.5”
(3.8 cm)
22” COVER
(56 cm)
3.5”
(8.9 cm)
Conduit Area
Chassis Base
14.5 x 16”
36.8 x 40.6cm
Cover Area
Output
Shaft
Center
12” (30.5 cm)
minimum
14”
(35.6 cm)
21” (53.3 cm)
minimum
10.5”
(26.7 cm)
5.3”
(13.4 cm)
10.5” (26.7 cm)
5.7” (14.5 cm)
23” (58.4 cm)
minimum
Output Shaft Center
Drill 4 holes for
½" x 3 ½" concrete
anchors
6" x 7" conduit
area
Pad Depth: 16" minimum
2" minimum
(51mm)
(41cm)
Low voltage/
Communication
wires
Primary/Secondary
wires - optional
High voltage
30.2"
76.7cm
26.8"
(68cm)
Vehicle Loop
control wires
Earth ground
Ground level
9.6" (24cm)
control box
height
Stub out conduit
4-inches (102mm)
above ground
level
2-inch (51cm)
height above pad.
26
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018
Содержание SwingSmart DC 20
Страница 2: ...2 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 24: ...SAFETY INFORMATION 24 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 138: ...NOTES 138 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 139: ...NOTES 139 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...