HyQual Multi-probes User Manual v3, 08.07.2022 
KISTERS Controlled, Template: Word-with-table-of-contents-Template-Company.docx, v1.1 

Page 6 / 23 

 

 
Connectivity and Visualization 

 

When using a smartphone, tablet or other display device (Android™) you would need to add to your 

package the 

Bluetooth

® wireless technology battery pack which allows to connect the external device 

with the probe via 

Bluetooth

® wireless technology and additionally provides external power to the in-

strument.  

 

HyQual also connects to a PC with the use of the optional USB Converter. 

 

Vented capacity 

 

With the vented depth sensor, the multiprobe automatically corrects depth measurments for changes in 
Barometric Pressure.  
 
Please note that vented capacity is optional, it requires to add an optional depth sensor, optional vented 
depth capacity, and an optional vented cable. 
 
Additionally, this capacity is incorporated in the probe so you will add it when purchasing the probe. If 
you happen to have a probe and need to incorporate this capacity, you will have to send the probe back 
to us at your own expense. 
 

Additional sensors 
 

Barometric pressure is calculated with the use of the depth sensor therefore, you will need to add an 
optional depth sensor to any of your probes HyQual 200, HyQual 300 and HyQual 300T. 
 
When  Absolute  Pressure  method  is  used  (non-vented  capacity)  there 

are  three  ways of obtaining  the 

value of Barometric Pressure: 
a)           With the use of a theorical Barometric Pressure 
b)           With the use of the depth sensor, by taking the probe out of the water and placing it at the water 
surface so that the probe only measures the Barometric Pressure 
c)           With a barometer (any brand) 
 
Please note that barometric pressure value is needed for the calibration of the DO sensor. 

 

Safety Instructions

 

2.1

 

General Safety Instructions 

Read the user manual including all operating instructions prior to installing, connecting and powering up 
the HyQuest Solutions HyQual unit. The manual provides information on how to operate the product. 
The manual is intended to be used by qualified personnel, i.e. personnel that have been adequately 
trained, are sufficiently familiar with installation, mounting, wiring, powering up and operation of the 
product. 
 
Keep the user manual on hand for later reference. 
 

Содержание HyQual

Страница 1: ...HyQual Water Quality Multi Probe HyQuest Solutions KISTERS Group 2022 05 03...

Страница 2: ...ction 10 6 2 2 Unattended Logging 10 6 2 3 Telemetry Relay 11 6 2 4 On Line Monitoring 12 7 1 When to proceed to maintenance 12 7 2 Maintenance 1 Keep your device clean 12 7 3 Maintenance 1 Calibratio...

Страница 3: ...ilidad de tales da os Cualquier error encontrado en cualquier producto de HyQuest Solutions debe ser comuni cado a HyQuest Solutions donde se har todo lo posible para resolver r pidamente el pro blema...

Страница 4: ...industrial specification that defines the electrical interface and physical layer for point to point communication of electrical devices The RS 485 stand ard allows for long cabling distances in elec...

Страница 5: ...s battery operates only at the surface and its job is to power the multiprobe while you re pairing the instrument with a data display via Bluetooth wireless technology A USB port on a PC is another wa...

Страница 6: ...send the probe back to us at your own expense Additional sensors Barometric pressure is calculated with the use of the depth sensor therefore you will need to add an optional depth sensor to any of yo...

Страница 7: ...ufacturer s named repair center You can find information on how to re turn items for repair in the relevant section of the HyQuest Solutions website Disposal instructions After taking any HyQuest Solu...

Страница 8: ...ufficient water flow that can be easily ac cessed for maintenance and protected from external elements such as animals and items such as stones or sticks that may damage the probe 4 1 Protection for u...

Страница 9: ...n to toggle between Logging ON and Logging OFF The Setup function for Logging lets you name your Logging file and set the logging interval time be tween logged lines of data Figure 1 Switch Logging ON...

Страница 10: ...The Display can be a laptop or almost any tablet or smart phone You can record measurements using the HyQual probe s Snapshot or Automatic Snapshot features You might snapshot a series of measurements...

Страница 11: ...rchase this battery after as it is not integrated to the probe Please note that this battery ads several inches to the length of the probe and that it can also be used with the HyQual 200 only that it...

Страница 12: ...ed in the control loop or decision making process Maintenance 7 1 When to proceed to maintenance Judgment gained from observing your field conditions and data requirements provides information about w...

Страница 13: ...tuation for which the correct parameter value is known Here s the general procedure 1 Clean the sensor and perform any necessary sensor specific maintenance 2 Select a calibration standard whose value...

Страница 14: ...c But you can elect to accept any SRF 7 3 3 Choosing Calibration Standards For best results choose a calibration standard whose value is close to what you expect to see in the field For example calibr...

Страница 15: ...ate of the calibration the parameter calibrated the reading before the calibration was accepted the read ing after the calibration was accepted the raw sensor reading the SRF and a few other details I...

Страница 16: ...follow the calibration instructions on the screen The manufacturers of optical DO sensors usually recommend that you not calibrate the zero DO point because the zero DO point drift is very low However...

Страница 17: ...don t report because it has little meaning in natural waters You can t calibrate TDS or salinity directly because they are calculated from Conductivity You can however calibrate TDS with a TDS standar...

Страница 18: ...ous circle at the end of the sleeve This not only purges bubbles from the electrolyte but also cleans nasty stuff out of the junction Figure 4 Filling in fresh pH reference electrolyte 7 3 10 ORP ORP...

Страница 19: ...s a small hole in the back of the transducer There is a tube inside the cable i e a Vented Cable to connect the Stage sensor to the atmosphere so that changes in barometric pressure will not affect t...

Страница 20: ...e small set screw on the wiper arm 2 Remove the wiper pad from the wiper arm and replace the pad 3 Place a new wiper arm on the motor shaft so that the set screw faces the flat spot on the motor shaft...

Страница 21: ...bor charge 1 2 days down time Repair HyQuest Solutions precision instruments and data loggers are produced in quality controlled processes All HyQuest Solutions production and assembly sites in Austra...

Страница 22: ...lay devices not for eld use calibration solutions copper anti fouling kit USB adapter connect DB9 to USB inte grated SDI 12 and MODBUS output SDI 12 adapter cable MODBUS adapter cable and Android disp...

Страница 23: ...ion battery must be dis posed of according to legal provisions EU WEEE Directive As players in the environmental market KISTERS AG and HyQuest Solutions are committed to supporting efforts to avoid a...

Отзывы: