Hypro 3300-0102 Скачать руководство пользователя страница 1

Model 3300-0102 & 3300-0103 High Flow

Balanced Pressure Regulator Valves

Installation & Operation Instructions

Form L-1523

11/09

Installation

As a relief valve, this valve should be placed in an area that remains pressurized when the gun is shut off.  
As a pressure regulator, the valve maintains the pressure in the system (even during flow changes). In this condition,

always use a suitable safety valve.  If the bypass is directed directly into the pump, caution should be taken to avoid

excessive water temperature increases.

Operation

IMPORTANT

:

The bypass port is at the bottom. The inlet port is on the side.

The bypass should be returned to a baffled tank for turbulence control.

Pressure Adjustment/Setting

As a relief valve, the adjustment has to be made in such a way that the pressure setting is not higher than the system’s

working pressure.
As a pressure regulator, adjust the valve when the system is pressurized and the gun is open.  As the adjustment cap is

turned, there should be a corresponding change in pressure. To increase the pressure, turn the cap clockwise; to

decrease the pressure, turn the cap counterclockwise. Once the desired pressure is reached, tighten the ring nut to lock

the cap in place.

Max. Flow Pressure Range Max Temp.

Inlet Port

Bypass Port

Dimensions

Standard

55 GPM

260-2000 PSI

185º F

3/4” NPT

1/2” NPT

6.25” x 2.00” x 1.50”

Metric

208 LM

18-138 BAR

85º C

3/4” NPT

1/2” NPT

159 x 50 x 38 mm

Specifications for 3300-0103

Standard

55 GPM

260-2000 PSI

185º F

1” NPT

1” NPT

6.25” x 2.90” x 1.65”

Metric

208 LM

18-138 BAR

85º C

1” NPT

1” NPT

159 x 74 x 42 mm

Specifications for 3300-0102

Order Information

Part No.

Description

3300-0102

3/4” NPT Inlet x 1/2” NPT Bypass Model

3300-0103

1” NPT Inlet x 1” NPT Bypass Model

3430-0747

Piston and Seat Repair Kit

Troubleshooting

Valve chatters

Valve is installed improperly (inlet & bypass may be reversed).

Valve is missing its orifice washer. 

Valve is improperly set; repeat adjustment process.

Valve continually bypasses

Seat or piston worn; replace as needed. 

Valve is improperly set; repeat adjustment procedure.

Leaking out the top of valve

O-ring and piston are worn or cut. Install repair kit.

Отзывы: