background image

Safety and compliance

11

Warranty

Attention

Genuine Hypertherm parts are the factory-recommended replacement 
parts for your Hypertherm system. Any damage or injury caused by the 
use of other than genuine Hypertherm parts may not be covered by the 
Hypertherm warranty, and will constitute misuse of the Hypertherm 
Product.

You are solely responsible for the safe use of the Product. Hypertherm 
does not and cannot make any guarantee or warranty regarding the safe 
use of the product in your environment.

General

Hypertherm, Inc. warrants that its Products shall be free from defects in 
materials and workmanship for the specific periods of time set forth 
herein and as follows: if Hypertherm is notified of a defect (i) with respect 
to the plasma power supply within a period of two (2) years from the date 
of its delivery to you, with the exception of Powermax brand power 
supplies, which shall be within a period of three (3) years from the date of 
delivery to you, and (ii) with respect to the torch and leads within a period 
of one (1) year from its date of delivery to you, with the exception of the 
HPRXD short torch with integrated lead, which shall be within a period of 
six (6) months from the date of delivery to you, and with respect to torch 
lifter assemblies within a period of one (1) year from its date of delivery to 
you, and with respect to Automation products one (1) year from its date 
of delivery to you, with the exception of the EDGE Connect CNC, 
EDGE Connect T CNC, EDGE Connect TC CNC, EDGE Pro CNC, 
EDGE Pro Ti CNC, MicroEDGE Pro CNC, and ArcGlide THC, which 
shall be within a period of two (2) years from the date of delivery to you, 
and (iii) with respect to HyIntensity fiber laser components within a 
period of two (2) years from the date of its delivery to you, with the 
exception of laser heads and beam delivery cables, which shall be within 
a period of one (1) year from its date of delivery to you.

All third-party engines, engine accessories, alternators, and alternator 
accessories are covered by the respective manufacturers’ warranties and 
not covered by this warranty.

This warranty shall not apply to any Powermax brand power supplies that 
have been used with phase converters. In addition, Hypertherm does not 
warranty systems that have been damaged as a result of poor power 
quality, whether from phase converters or incoming line power. This 
warranty shall not apply to any product which has been incorrectly 
installed, modified, or otherwise damaged.

Hypertherm provides repair, replacement or adjustment of the Product as 
the sole and exclusive remedy, if and only if the warranty set forth herein 
properly is invoked and applies. Hypertherm, at its sole option, shall 
repair, replace, or adjust, free of charge, any defective Products covered 
by this warranty which shall be returned with Hypertherm’s prior 
authorization (which shall not be unreasonably withheld), properly 
packed, to Hypertherm’s place of business in Hanover, New Hampshire, 
or to an authorized Hypertherm repair facility, all costs, insurance and 
freight pre paid by the customer. Hypertherm shall not be liable for any 
repairs, replacement, or adjustments of Products covered by this 
warranty, except those made pursuant to this paragraph and with 
Hypertherm’s prior written consent.

The warranty set forth above is exclusive and is in lieu of all other 
warranties, express, implied, statutory, or otherwise with respect to the 
Products or as to the results which may be obtained therefrom, and all 
implied warranties or conditions of quality or of merchantability or fitness 
for a particular purpose or against infringement. The foregoing shall 
constitute the sole and exclusive remedy for any breach by Hypertherm 
of its warranty.

Distributors/OEMs may offer different or additional warranties, but 
Distributors/OEMs are not authorized to give any additional warranty 
protection to you or make any representation to you purporting to be 
binding upon Hypertherm.

Patent indemnity

Except only in cases of products not manufactured by Hypertherm or 
manufactured by a person other than Hypertherm not in strict conformity 
with Hypertherm’s specifications and in cases of designs, processes, 
formulae, or combinations not developed or purported to be developed 
by Hypertherm, Hypertherm will have the right to defend or settle, at its 
own expense, any suit or proceeding brought against you alleging that 
the use of the Hypertherm product, alone and not in combination with 
any other product not supplied by Hypertherm, infringes any patent of 
any third party. You shall notify Hypertherm promptly upon learning of any 
action or threatened action in connection with any such alleged 
infringement (and in any event no longer than fourteen (14) days after 
learning of any action or threat of action), and Hypertherm’s obligation to 
defend shall be conditioned upon Hypertherm’s sole control of, and the 
indemnified party’s cooperation and assistance in, the defense of the 
claim.

Limitation of liability

In no event shall Hypertherm be liable to any person or entity for 
any incidental, consequential direct, indirect, punitive or 
exemplary damages (including but not limited to lost profits) 
regardless of whether such liability is based on breach of 
contract, tort, strict liability, breach of warranty, failure of 
essential purpose, or otherwise, and even if advised of the 
possibility of such damages. Hypertherm shall not be liable for 
any losses to Distributor based on down time, lost production or 
lost profits. It is the intention of the Distributor and Hypertherm 
that this provision be construed by a court as being the 
broadest limitation of liability consistent with applicable law.

National and local codes

National and local codes governing plumbing and electrical installation 
shall take precedence over any instructions contained in this manual. 
In no event shall Hypertherm be liable for injury to persons or property 
damage by reason of any code violation or poor work practices.

Содержание SmartSYNC Robotic Torch

Страница 1: ...SmartSYNC Robotic Torches Operator Manual 811450 REVISION 0 ENGLISH ...

Страница 2: ...countries All other trademarks are the property of their respective holders Environmental stewardship is one of Hypertherm s core values and it is critical to our success and our customers success We are striving to reduce the environmental impact of everything we do For more information www hypertherm com environment 2022 Hypertherm Inc ...

Страница 3: ...Hypertherm Inc Hanover NH 03755 USA www hypertherm com SmartSYNC Robotic Torches Operator Manual 811450 REVISION 0 ENGLISH Original instructions November 2022 ...

Страница 4: ...agen 100 3317 DM Dordrecht Nederland 31 165 596907 Tel 31 165 596901 Fax 31 165 596908 Tel Marketing 31 0 165 596900 Tel Technical Service 00 800 4973 7843 Tel Technical Service technicalservice emeia hypertherm com Technical Service Hypertherm Shanghai Trading Co Ltd B301 495 ShangZhong Road Shanghai 200231 PR China 86 21 80231122 Tel 86 21 80231120 Fax 86 21 80231128 Tel Technical Service techsu...

Страница 5: ... vesileikkauksen turvallisuuden ja vaatimustenmukaisuuden käsikirja 80943C ja radiotaajuusvaroitusten käsikirja 80945C Käyttöoppaiden kopiot voivat olla tuotteen mukana sähköisessä ja tulostetussa muodossa Sähköiset kopiot ovat myös verkkosivustollamme Monet käyttöoppaat ovat myös saatavissa useilla kielillä www hypertherm com docs FR FRANÇAIS FRENCH AVERTISSEMENT Avant d utiliser tout équipement ...

Страница 6: ...ránke www hypertherm com docs SL SLOVENŠČINA SLOVENIAN OPOZORILO Pred uporabo katerekoli Hyperthermove opreme preberite varnostna navodila v priročniku vašega izdelka v Priročniku za varnost in skladnost 80669C v Priročniku za varnost in skladnost sistemov rezanja z vodnim curkom 80943C in v Priročniku Opozorilo o radijskih frekvencah 80945C Izvodi priročnikov so lahko izdelku priloženi v elektron...

Страница 7: ...mation 13 2 Specifications 15 About the robotic torch 15 Robotic torch components dimensions weights 16 Components 16 Dimensions 16 180 robotic torch 16 90 robotic torch 17 45 robotic torch 17 Weights 17 3 Mount the Robotic Torch 19 Minimum bend radius 20 Mount with a Hypertherm robotic torch clamp 228806 20 Connect the torch lead 23 ...

Страница 8: ...27 Select the cartridge 27 Cutting guidelines 28 Piercing guidelines 29 Gouging processes 30 Change the gouge contour 31 5 Troubleshooting and Maintenance Tasks 35 Cutting system problems 36 Cut quality problems 38 Cut angle bevel 38 Dross 39 Gouging problems 40 Routine maintenance 41 Every use 42 Every 3 months 43 Cartridge maintenance 44 ...

Страница 9: ... User shall ensure that other equipment being used in the environment is compatible This may require additional protection measures h Time of day that cutting or other activities are to be carried out The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place The surrounding area may extend beyond the boundaries of the ...

Страница 10: ...es where direct connection is not permitted the bonding should be achieved by suitable capacitances selected according to national regulations Note The cutting circuit may or may not be earthed for safety reasons Changing the earthing arrangements should only be authorized by a person who is competent to assess whether the changes will increase the risk of injury for example by allowing parallel c...

Страница 11: ...erly packed to Hypertherm s place of business in Hanover New Hampshire or to an authorized Hypertherm repair facility all costs insurance and freight pre paid by the customer Hypertherm shall not be liable for any repairs replacement or adjustments of Products covered by this warranty except those made pursuant to this paragraph and with Hypertherm s prior written consent The warranty set forth ab...

Страница 12: ...ein shall be null and void and you will have no further recourse against Hypertherm under the Warranty or otherwise Waterjet product warranty coverage Consumable parts are not covered by this warranty Consumable parts include but are not limited to high pressure water seals check valves cylinders bleed down valves low pressure seals high pressure tubing low and high pressure water filters and abra...

Страница 13: ... Cut Charts Guide 810500MU Powermax65 85 105 SYNC Mechanized Cutting Guide 810480 Safety and Compliance Manual 80669C For replacement part numbers for robotic torches torch accessories and cartridges refer to the Powermax65 85 105 SYNC Parts Guide 810490 You can find these documents on the USB memory stick that came with your plasma power supply Technical documentation is also available at www hyp...

Страница 14: ...Where to Find More Information 1 14 811450 Operator Manual SmartSYNC Robotic Torches ...

Страница 15: ...e torch lead length Communication of Hypertherm cartridge usage information to the plasma power supply including cartridge end of life detection Refer to the Powermax65 85 105 SYNC Operator Manual 810470 for more information The FastConnect quick disconnect system to easily remove the torch for transport or to change from one torch to another For information about the thicknesses that you can cut ...

Страница 16: ...omponents A SmartSYNC 180 robotic torch is shown Dimensions 180 robotic torch 1 2 6 5 3 4 7 1 Hypertherm cartridge 2 Shell 3 Increment markings 4 Anti rotational slot 5 Strain relief for torch lead 6 Torch lead 7 Positioning holes 3 32 mm 1 25 inch 35 mm 0 3 mm 1 37 inch 0 01 inch 235 mm 9 25 inch 180 mm 7 08 inch ...

Страница 17: ...86 mm 7 33 inch 139 mm 5 47 inch 100 mm 3 93 inch 32 mm 1 25 inch 32 mm 1 25 inch 35 mm 0 3 mm 1 37 inch 0 01 inch 214 mm 8 43 inch 139 mm 5 47 inch 76 mm 2 98 inch Torch Weight 180 robotic torch with 4 6 m 15 foot lead 2 1 kg 5 lb 180 robotic torch with 7 6 m 25 foot lead 3 1 kg 7 lb 180 robotic torch with 15 m 50 foot lead 5 7 kg 13 lb Without a Hypertherm cartridge installed ...

Страница 18: ...foot lead 3 5 kg 8 lb 90 robotic torch with 15 m 50 foot lead 6 5 kg 14 lb 90 robotic torch with 23 m 75 foot lead 9 6 kg 21 lb Without a Hypertherm cartridge installed Torch Weight 45 robotic torch with 7 6 m 25 foot lead 3 5 kg 8 lb 45 robotic torch with 15 m 50 foot lead 6 5 kg 14 lb 45 robotic torch with 23 m 75 foot lead 9 6 kg 21 lb Without a Hypertherm cartridge installed ...

Страница 19: ...Mount with a Hypertherm robotic torch clamp 228806 on page 20 If you use an alternate torch clamp comply with the manufacturer s instructions on how to mount the torch in the clamp For information about how to configure the Powermax power supply for remote operation refer to the Powermax65 85 105 SYNC Mechanized Cutting Guide 810480 NOTICE SENSITIVE ELECTRONICS AND OTHER COMPONENTS INSIDE THE TORC...

Страница 20: ...um bend radius of 76 mm 3 0 inches Mount with a Hypertherm robotic torch clamp 228806 1 Mount the torch clamp to the robot arm using mounting holes or NOTICE MINIMUM BEND RADIUS KINKING AND OTHER DAMAGE CAN OCCUR Do not bend the torch lead too far 76 mm 3 0 in 1 2 7 62 mm 0 30 inch 19 05 mm 0 75 inch 2 1 1 1 4 5 mm 0 18 inch unthreaded holes 2 M4 x 0 7 threaded holes ...

Страница 21: ...n the torch with the rear half of the clamp using either the increment markings or the positioning holes If you are using the increment markings remove the positioning dowel Push the dowel through the clamp 4 Make sure that the anti rotational tabs on each half of the torch clamp are aligned with the slot in the torch 1 2 1 2 5 2 6 3 4 1 1 2 3 4 5 6 ...

Страница 22: ...front half of the clamp to the rear half of the clamp with the 4 screws 6 Tighten the 4 screws to 1 7 N m 15 lbf in in the order shown 1 2 3 2 3 1 NOTICE Do not tighten the screws too much If you tighten the screws too much you can cause damage to the internal components of the torch 2 4 1 3 ...

Страница 23: ...r supply to OFF O before you connect or disconnect a torch To connect a hand torch or machine torch push the connector into the receptacle on the front of the plasma power supply The connector makes a click when it is fully engaged To disconnect the torch push the red button on the connector and pull the connector out of the receptacle Red button ...

Страница 24: ...Mount the Robotic Torch 3 24 811450 Operator Manual SmartSYNC Robotic Torches ...

Страница 25: ...ion gives information to help you do the following Use the robotic teach tool Select the correct Hypertherm cutting or gouging cartridge Pierce and cut metal Optimize cut quality Gouge metal To troubleshoot cutting system problems refer to Troubleshooting and Maintenance Tasks on page 35 ...

Страница 26: ...e that the torch will not touch the workpiece while cutting Contact with the workpiece while cutting can cause damage to the cartridge and the cut surface The torch teach tool has a spring loaded tip so that you can simulate different cartridge lengths and stand off distances To install the torch teach tool do the following steps 1 Set the power switch on the plasma power supply to OFF O 2 Remove ...

Страница 27: ...ness of the material that you want to cut Make sure that the cartridge that you select is an amperage supported by the plasma power supply For example if you have a Powermax85 SYNC select an 85 A 65 A or 45 A cartridge not a 105 A cartridge Cartridge Type Purpose Standard cut gray Use these standard cartridges for the widest range of cutting applications FineCut gray Use these cartridges to get a ...

Страница 28: ...he workpiece Do all cutting system maintenance tasks as scheduled Refer to Troubleshooting and Maintenance Tasks on page 35 Do not fire the torch unnecessarily It decreases cartridge life Starting at the edge of the workpiece is permitted if the arc makes contact with the workpiece when started Prevent lead outs that move away from the workpiece and stretch the plasma arc Metric material thickness...

Страница 29: ...hat the arc can pierce the material before the torch moves but not so long that the pierce hole enlarges and causes the arc to wander or extinguish before the torch starts to move Pierce delay times given in the cut charts use average delay times throughout the life of the cartridges If necessary as the cartridge wears increase the pierce delay time Pierce height Pierce height is the distance betw...

Страница 30: ...ers the following gouging cartridges Cartridge Type Purpose Maximum Control gouging green Use these cartridges for more precise metal removal shallow gouge contours and light metal washing Maximum Removal gouging green Use these cartridges for aggressive metal removal deep gouge contours and extreme metal washing ...

Страница 31: ... 31 Change the gouge contour The width and the depth of the gouge contour are a result of the following factors Adjust these factors in combination to get the gouge that you want Standoff arc stretch Angle of the torch Turn of the torch Torch center line Speed Output current A ...

Страница 32: ...u can stretch the arc Hypertherm recommends that you keep amperage and arc stretch consistent The lowest and highest possible amperage setting relates to the plasma power supply and the Hypertherm cartridge you are using Angle of the torch to the workpiece Put the torch in a more upright position to make the gouge narrower and deeper Tilt down the torch so that it is closer to the workpiece to mak...

Страница 33: ...the output current A of the plasma power supply The higher the amperage the longer that you can stretch the arc Hypertherm recommends that you keep amperage and arc stretch consistent Keep at least a small distance between the torch tip and the molten metal to increase cartridge life and prevent damage to the torch Speed of the torch Increase the speed of the torch movement to make the gouge narro...

Страница 34: ...Operate the Robotic Torch 4 34 811450 Operator Manual SmartSYNC Robotic Torches ...

Страница 35: ...complying with the recommendations in this chapter or if further aid is necessary do the following 1 Get the serial number for your system from the data plate that is on the rear panel 2 Speak to your Hypertherm distributor or authorized repair facility 3 Speak to the nearest Hypertherm office shown in the front of this manual Refer to the Powermax65 85 105 SYNC Parts Guide 810490 for information ...

Страница 36: ...ge Replace it if it is worn or damaged A higher rate of 0 30 0 faults is typical as a cartridge gets near end of life Refer to the Powermax65 85 105 SYNC Operator Manual 810470 Decrease your cut speed Restart the plasma power supply Does it correctly recognize the type of cartridge installed Does it correctly set the amperage and operating mode to align with the cartridge If it does not look at th...

Страница 37: ...Powermax65 85 105 SYNC Cut Charts Guide 810500MU Use the correct torch height for piercing Refer to the Powermax65 85 105 SYNC Cut Charts Guide 810500MU for the initial pierce height Make sure that the pierce delay time is correct Refer to the Powermax65 85 105 SYNC Cut Charts Guide 810500MU Examine the gas filtration system for signs of contaminants that Refer to the Powermax65 85 105 SYNC Operat...

Страница 38: ...e top The cutting speed is too slow The torch is too low The amperage is too high Increase the cutting speed in small increments 125 mm min or 5 in min or less Lift the torch in small increments 2 mm or 1 16 in Decrease the amperage in 10 A increments No bevel square cut This is good cut quality Positive bevel More material is removed from the top of the cut than from the bottom The cartridge is w...

Страница 39: ...ts on the bottom of the cut and is heavy and bubbly The cutting speed is too slow The torch is too low Or if you are using a torch height control arc voltage is too low The amperage is too high Increase the cutting speed in small increments 125 mm min or 5 in min or less Lift the torch in small increments 2 mm or 1 16 in Or if you are using a torch height control increase the arc voltage in small ...

Страница 40: ...pright position The torch tip hits the molten metal slag Increase the arc stretch standoff Keep the torch tip pointed in the direction of the gouge that you want to make The gouge has too much depth Tilt the torch down so that it is closer to the workpiece Increase the arc stretch standoff Increase the gouging speed Decrease the output current A The gouge does not have enough depth Put the torch i...

Страница 41: ...ll work that requires removal of the plasma power supply outer cover or panels must be done by a qualified technician Refer to the Safety and Compliance Manual 80669C for more safety information WARNING RISK OF BURNS AND ELECTRIC SHOCK USE INSULATED GLOVES Always put on insulated gloves when changing the cartridges The cartridges get very hot during cutting and can cause severe burns Touching the ...

Страница 42: ...Refer to Cartridge maintenance on page 44 To prevent overheating do the following Examine the work lead connector to make sure that it is fully connected to the plasma power supply and is not loose Make sure that you turn the connector clockwise approximately 1 4 turn until the connector is fully engaged and locked in position Do a check of the plug on the work lead When a plug is replaced damage ...

Страница 43: ... Parts Guide 810490 Examine the torch for cracks and exposed wires Have a qualified service technician replace any damaged parts Contact your distributor or authorized repair facility Examine the labels Replace any damaged labels Refer to the Powermax65 85 105 SYNC Parts Guide 810490 Examine the torch lead Have a qualified service technician replace it if it is damaged Contact your distributor or ...

Страница 44: ...zle or shield Carefully remove molten metal that causes a blockage of the holes in the shield that are necessary for airflow Do not push the unwanted material inside the nozzle or shield Examine the O ring on the torch body If the O ring is cracked or worn replace it If the O ring is dry or if it is not easy to install the cartridge apply a thin layer of silicone lubricant on the O ring and the th...

Отзывы: