RS-485 Serial Interface Receptacle with PCB
8
806710
Field Service Bulletin
Powermax65/85/105/125, Powermax65/85/105 SYNC
Loosen the rear panel of the plasma power supply
1.
Remove the end panel bracket
. Some models have 2 screws
on the end panel bracket
that you must first remove.
2.
Put the fan side of the plasma power supply on a clean, dry, and flat surface.
3.
Remove the screws
that attach the rear panel to the bottom of the plasma power supply.
Some models have 2 screws on the bottom of the plasma power supply, and other models have
3 screws on the rear panel instead.
1
2
1
2
2
3