TroubleshooTing and sysTem TesTs
powermax
65/85
Service Manual
5-43
Test 4 – Inverter and PFC temperature sensor
Symptom: Fault code 0-40 appears in the operator screen.
Remove power and allow the system to reach room temperature (at least 60 minutes after use).
If the system has a temperature interlock, either fault code 0-40 or fault code 0-99 appears on the operator screen.
Display the service screen and check the “F” field for the live (most recent) fault code. Fault code 0-40 appears on the
operator screen, but you need to identify the specific 0-40 fault code variation:
• 0-40-0 PFC module under temperature.
• 0-40-1 PFC module over temperature.
• 0-40-2 Inverter module under temperature.
• 0-40-3 Inverter module over temperature.
If fault code 0-99 appears on the operator screen, display the service screen and check the “F” field for:
• 2-10-0 Inverter module temperature sensor open.
• 2-10-1 Inverter module temperature sensor shorted.
• 3-11-0 PFC module temperature sensor open.
• 3-11-1 PFC module temperature sensor shorted.
Содержание Powermax 65
Страница 1: ...Service Manual 807120 Revision 1 Plasma arc cutting systems ...
Страница 10: ...vi powermax65 85 Service Manual ...
Страница 16: ...Table of Contents xii powermax65 85 Service Manual ...
Страница 32: ...Specifications 1 16 powermax65 85 Service Manual ...
Страница 182: ...Troubleshooting and System Tests 5 56 powermax65 85 Service Manual ...
Страница 200: ...Component Replacement 6 18 powermax65 85 Service Manual 1 4 6 2 3 3 3 5 DSP back view DSP front view ...
Страница 216: ...Component Replacement 6 34 powermax65 85 Service Manual ...
Страница 244: ...Wiring Diagrams 8 2 powermax65 85 Service Manual ...
Страница 247: ...8 5 Electrical schematic diagram CSA ...
Страница 248: ...8 6 Electrical schematic diagram CE ...