170
Powermax125
Service Manual 808070
9 – Power Supply Component Replacement
Installing the optional filter kit
1.
Disconnect the power and gas supply. (See
Disconnect the power and gas supply
2.
Remove the gas inlet fitting
from the bracket
.
Figure 36
3.
Apply thread sealant to the adapter fitting and tighten it into the bracket. (See
4.
Apply thread sealant to the other side of the adapter fitting, and, with the arrow pointing toward the power supply,
tighten the filter onto the adapter fitting.
5.
Apply thread sealant to the gas inlet fitting, and tighten it into the filter.
Kit number
Description
Kit: Eliminizer gas filter with protective metal cover for the Powermax105/125
CAUTION!
Never use PTFE tape on any joint preparation. Use only a liquid or paste thread sealant on male
threads.
1
2
1
2