5 – Preventive maintenance
Preventi
ve maintenance
Start the pump after preventive maintenance
1.
Turn ON the water to the pump.
2.
Turn ON the electrical main.
3.
Make sure that the primary breaker disconnect lever on the electrical enclosure door is set to ON.
The operator interface screen is illuminated when electricity to the pump is turned on.
4.
Make sure that the LOCAL/REMOTE key switch on the operation panel is set to LOCAL.
These events occur when the key switch is set to LOCAL:
The operator interface is used to run the pump.
The REMOTE ACTIVE indicator light is off.
The operator interface is the primary point of control.
5.
Push the CONTROLS ON button to turn ON the control circuit inside the pump.
The pump can not be turned on until the control circuit is on.
WARNING
Before removing lock-out or tag-out devices:
• Follow the specific provisions of the employer’s energy-control procedure.
• Inspect machines and parts to make sure that they are operationally intact and that nonessential
items are removed from the area.
• Make sure that everyone is safely away from machines.
After removing the lock-out or tag-out devices but before reenergizing the machine, the make sure
that all workers in the area of the equipment know that the devices are removed and that the
machine is capable of being reenergized.
WARNING
A turning motor shaft can be dangerous. Close all doors and replace all covers, including access
covers.
WARNING
Do not attempt to repair a leak with pressure in the system.
WARNING
Use a piece of cardboard or other solid material to check for leaks when the pump is on. Do not use
hands, cloth, paper, or towels.
CAUTION
Failure to correct the cause of a leak can cause damage to the water fittings.
Make sure that all fittings are tight after doing maintenance or repairing this equipment.
Test the equipment before putting it into use.
Remove all tools from the work area before starting the equipment.
Содержание HyPrecision 50S
Страница 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Страница 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Страница 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Страница 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...