HyPrecision15/30/50
Operator
Manual 808240
99
5 – Preventive maintenance
Preventive maintenance
Replace the bleed-down valve body
Replace this part if water leaks from the wastewater outlet or from the weep holes while the pump is running.
1.
Disassemble the bleed-down valve. Refer to page 128 for instructions.
2.
Discard the used parts.
3.
Install the bleed-down valve body, output adapter, flow reducer, seat, needle, needle guide, and seal.
4.
When all maintenance tasks are complete, reassemble the parts.
CAUTION
Failure to correct the cause of a leak can result in damage to the fittings.
CAUTION
Overtightening a fitting can cause it to fail. Use 2 wrenches when loosening or tightening a high-pressure
connection. Using only 1 wrench can increase bending stress to the parts and cause damage or premature
failure.
Repair or replace parts identified in the preventive maintenance schedule or if the parts show signs of
deterioration, corrosion, or damage.
Put the parts on a clean, dry, oil-free surface.
Содержание HyPrecision 15
Страница 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Страница 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Страница 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Страница 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Страница 146: ...146 HyPrecision15 30 50 Operator Manual 808240 5 Preventive maintenance Preventive maintenance ...
Страница 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Страница 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Страница 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...