HyPrecision15/30/50
Operator
Manual 808240
131
5 – Preventive maintenance
Preventive maintenance
Disassemble the bleed-down valve
Repair the bleed-down valve after every 1,000 hours of operation.
Replace the bleed-down valve body after every 3,000 hours of operation.
Required tools, materials, and parts
Clean, lint-free towel
Isopropyl alcohol
3/4-inch open-ended wrench
1-1/8-inch open-ended wrench (to hold the valve body)
Wooden dowel
1.
Remove the outlet adapter from the valve body.
2.
Remove the seat and the flow reducer from the outlet adapter.
3.
Remove the actuator from the valve body.
4.
Push a dowel through the bottom of the valve body to remove the seal, the needle guide, and the needle.
1
2
3
4
5
6
7
8
1
Actuator
2
Needle guide
3
Needle
4
High-pressure valve seal
5
Valve body
6
Seat
7
Flow reducer
8
Outlet adapter
Содержание HyPrecision 15
Страница 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Страница 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Страница 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Страница 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Страница 146: ...146 HyPrecision15 30 50 Operator Manual 808240 5 Preventive maintenance Preventive maintenance ...
Страница 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Страница 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Страница 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...